Get complete information related to latest Indicator Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Indicator Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Indicator Switch Tenders.
Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep
Tender For supply of alternator 12v 135 amp , alternator 12 v 55 amp , castle nut m 14x1 5 is 2232 , reverse indicatorswitch , side indi lamp lh , side nidi lamp rh
Tender For supply of wire 1.5 sqmm gm , wire 2.5 sqmm gm , wire 1 sqmm gm , indicatorswitch , u clip , concreate nails 2 inch , sigsaw blade , white paint , oil stone , l profile pvc , u profile pvc , raw sena powder , chalk powder , wood stainer yellow walnut , wood sealer , nc thinner , pu thinner , pu polish , ply wood 8 inch by 4 inch 12 mm , sand paper 100 by 120 , sand paper 220 by 320 , turkey amber powder , wood thinner , conreate bit 6 mm and 8 mm
Tender For supply of poly film tubes 1 to 10 mm pack of 20 , clamp meter fluke , twisted wire wheel cup brush , combination drill tap bit set 6 pcs , drive pin punch set , 7 drawer roller tool cabinet , tyre tube puncture repair machine portable , rubber mat for elect sec 5mm , insulated screw dvr set stanley , switch socket 15 amp with indicator , switch socket 5 amp , office chairs , digital bore gauge kit 50 to 160mm , hy duty universal hyd gear box trolley jack 2 ton , premium cordless hammer drill machine dewalt , jump lead for heavy veh , heavy duty forged steel wire set of six
Tender For procurement of spare parts for welland & tuxhorn make hydraulic drive system for lp bypass system and abb make 3 phase unbalance monitoring relay- 3 phase unbalance rms monitoring relay (100077739), fuse 6a (100189159), led lamp-3h1 (100189160), led lamp-3h2 (100189161), switch-3s1 (r100189162), relay-3k1 (100189163), relay-3k2 (100189164), relay-6k5 (100189165), safety relay-6k1 (100189166), signal isolator (passive) (100189167)
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r