Web Analytics Made Easy - StatCounter

Industrial Township Tenders

Get complete information related to latest Industrial Township Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Industrial Township Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Industrial Township Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Corporations/Associations/Others

CTN :45532318 Due date: 09 Jul, 202609 Jul, 2026 19.50 Lacs
Tender For corrigendum : repair and maintenance work of foot path and light arrangements,eb board,play materials and name board works in tnhb p-iii park at ward no.33 zone -4 in tcmc - eangaging of man power for cleaning weeds and bushes at lawn areas cutting plants and grass including all labour charges etc complete, gardener 5 days 6 nos, mazdoor ist class, engaging of ac electric grass cutter on hire basis including hire charges transport charges and all labour charges etc complete, supply and fixing of childerns play materials including cost and conveyance and fixing and proper alingenement charges etc complete, slider, 2 seater swing, 4 seater see saw, supplying and filling in foundation and basement with river sand in play area in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification., supply and fixing of light pole 4 metre length single bracket pole with base plate (250 x 250 x 6mm)76.10mm od x 3.65mm thick x 4000mm length etc.,completed, supply and fixing of 30w led street light fitting with led on out door fittings including cost and conveyance and fixing charges etc complete, supply and fixing of synthetic moulded compound box for street light with 16 a mcb and connecterincluding cost and conveyance and fixing charges etc complete box-735+16 a mcb sp and neutral -382, supply and fixing of 4 sqmm pvc unsheathed copper cable including cost and conveyance and fixing charges etc complete , supply and laying of 2 x 10 sq.mm pvc armoured ltug cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good sd 194, centering and shuttering charges for all pcc and rcc works using ms steel moulds and soffits strutting with casurina props 10-13 cm dia including cost and conveyance of all materials and including all labour charges etc complete, plain cement concrete 1;2;4 mix using 20 mm hbg iss metal including cost and conveyance of all materials and including all labour charges etc complete, supply and filling of on quarry rubbish 15 cm thick on each layer including cost and conveyance and all labour charges for filling and consolidation charges etc complete, cement concrete 1:5:10 (one cement, five crushed stone sand and ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard speci cation and as directed by the departmental of cers. -mixing by manual means, paving the oor with pre-polished concrete anti-skid tiles (required shape and design) of 20mm thick of approved quality and colour laid in accordance with is 1443 over a cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required cement slurry and mortar plasticizer and pointed with white cement mixed with colouring pigment at the rate of 0.40 kg. / sq.m., curing, etc., complete complying with standard speci cation and as directed by the departmental of cers. (the make and brand of the tiles should be got approved by executive engineer before use on works), supply and fixing of m.s grills with doors and windows with one coat of red oxide with primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification., supply and fixing of stone bench including cost and conveyance and fixing and proper alingenement charges etc complete, supply and delivery of ms kiosk of size 0.75m x 0.45m x 0.75m made up of ms angle of size 50mm x 50mmx 4mm alround covered with 16 gauge ms sheet and kiosk door made up of ms plates of size 25 mm x 3 mm including cutting, welding, grinding, locking arrangements and labour charges etc.,(twad sor 2025-26 unicode wd-m1471 clau

State Government

CTN :45721834 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For supplying electrical materials and repair maintenance services for street lights and electrical works at. grampanchayat somatane - electrical material, supplying and erecting modular type switch6a / 10a ., supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia b class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded ., providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles), supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation., supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, base plate in provided foundation., supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness (5.60 + 2.7 + 2.7 m) length total 11 m long with pole cap, base plate in provided foundation ., supplying and erecting street light bracket made from 25mm. dia b class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification, supplying,tpmcb 40a to 63a in provided distribution board, providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply., supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse, supplying h.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a, supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching on & switching off street light as per daily sunset and sunrise respectively, 1.25 mm crca sheet metal enclosures with 20a., supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable ., supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink ., supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink., supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink., supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95,class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium ., supplying & laying pvc armoured cable 4core 6sq mm, supplying & laying pvc armoured cable 4core 10 sq mm, supplying & laying pvc armoured cable 2core 10 sq mm, supplying & laying pvc armoured cable 4core 16 sq mm, supplying, erecting & marking spmcb 6a to 32a, b- series (for lighting), supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting), supplying, erecting & marking tpmcb 6 a to 32amp ., supplying, erecting & marking fpmcb 40a to 63a ., supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm., supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm., supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials., supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunk

corporations/Associations/Others

CTN :45733298 Due date: 07 Jul, 202607 Jul, 2026 1.85 Lacs
Tender For repair of huts by providing and fixing kota stone and skirting in various parks of sector 39, 40, 41, chandigarh, under revenue head.

Central Government/Public Sector

CTN :45713850 Due date: 11 Jul, 202611 Jul, 2026 27.00 Lacs
Tender For repair/replacement to doors, window, ventilators, cupboards, flooring/ plastering, tilling and other miscellaneous joinery /sanitary items at af stn aastha complex, 5 aflu under aor of ge (af) faridabad - demolition/dismantling of brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc, complete all as specified and directed., m&l for brickwork with subclass b bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in cm 1:6 complete all as specified and directed., all as per item no 02.00 above but except bricks., m&l for brick work with sub class b bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in cm 1:4 complete all as specified and directed., taking down cement plaster of any description on concrete surfaces such as soffit of rcc slab, chajjas and brick walls, ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed., m&l for rendering 15 mm thick cement plaster in cm 1:6 on brick work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed., m&l for rendering 15mm thick in cm 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl wpc as per user manual complete all as specified and directed., m&l for rendering 10mm thick in cm 1:3 over concrete surface as on ceiling, chajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed., m & l for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed., m&l for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed., m & l for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed., taking down chowkhats or frames with shutters not exc. 1.5 sqm each (without taking off shutters from the frames) complete all as specified and directed., taking down chowkhats or frames with shutters exc 1.5 sqm but not exc. 4 sqm each (without taking off shutters from the frames) complete all as specified and directed., taking down shutters of any description n exc 1 sqm each complete all as specified and directed., taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed., s&f for 30mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides and one face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed., s & f solid pvc door frame of size 50 x 47 mm made out of 5 mm plain colour pvc sheet reinforced with ms square tube incl taking down old frame any type complete all as specified and directed., s&f factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of ms tubes for top & bottom rails ms frame shall be convered with heat moulded plain colour pvc `c channel having a pvc sheet strip of 20 mm width stuck inside with solvant cement for stiles and plain colour pvc sheet top rail, lock rail and bottom rail on either side and as gap insert of top rail and bottom rail; paneling of plain c

Central Government/Public Sector

CTN :45713891 Due date: 20 Jul, 202620 Jul, 2026 20.00 Lacs
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20

Central Government/Public Sector

CTN :45475154 Due date: 07 Jul, 202607 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get

Central Government/Public Sector

CTN :45733876 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For invitation to pre-tender meet for repair and strengthening of stone masonry walls of phase 1 and phase 2 buildings at iit jodhpur

State Government

CTN :45128041 Due date: 28 Jul, 202628 Jul, 2026 NA
Tender For corrigendum : preparation of dpr including detailed layout, design and drawing of infrastructure services for new industrial township in rahpura jagir, bareilly

CTN :45563053 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For corrigendum : repair and raising of embankment and connecting it with already existing bank and providing boulder stone revetment with launching apron at bed of sukhna choe near rd 26800 to save agricultural land and abadies nearby

CTN :45733729 Due date: 09 Jul, 202609 Jul, 2026 5.50 Lacs
Tender For 31-repair to bridge over dhodra-simada nallah at 2nd km on dhodra simada to marigam road_road_repair of bridge railling,wearing coat,colour wash, stone packing, guard post and potholeat 2nd km. 1.950 to 2.050
 Loading, Please wait...

Connect us via What's Up