Get complete information related to latest Infiniband Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Infiniband Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Infiniband Switch Tenders.
Tender For time delay relay 110 v dc, 0.05s to 300 hrs, blinking interval 2second and used for external power supply /emergency brake of lhb type ac coaches, as per sr. no. 51 and i tem no k-01, place of tnstallation s1k18, as per the bill of material (bom) of- rdso spec no. rdso/pe/spec/ac /0184-2015(rev.1) & conforming to rdso specification no rdso/pe/spec/ac/01 84-2015(rev-1), suitable for lhb type ac coaches switch board cabinet. accepted make & cat alouge no.:- as per s. no. 56 of rdso letter no. el/7.1.108/mssbc, dated i7.09.2021 or any oth er rdso approved make & catalouge no. [ warranty period: 30 months after the date of delivery ]
Tender For supply of pvc copper cable single core and multi core circular sheathed cable with rigid conductor (v2) as per is 694 (q2) , joint kit , time switch , straight through joint kit , mcb 4 pole , end termination joint kit , cable pvc , bulb holder , batten holder , lamp holder , pvc seat for chair dining , rubber shoe for chair varandha , sand paper , paper sand , ms wood , aluminium sheet , float valve pvc 20mm , cp towel rail , gi union socket , screw full threaded , pvc washer
Tender For supply of switch plate assembly complete with polycarbonate cover frame and powder coated steel pl ate consists of (i) on-off switch - 4 nos. (ii) 3 pin socket (6a, 250v, ac) - 1 no. (iii) glass fuse 1a of m/s. fe rraz shawmut / cooper busman / equivalent (with fuse holder) - 1 no. as per icf specification no. icf/edml - 012, rev. b with drawing no. icf/sk 3-7-4-013, alt. c, item no.1. the switch plate assembly shall be in th e following order with inscription as l, f, nl, cs, 110v. make: sks, ssk, salzer, cpl, havells, clia, record o r any other make approved by icf/rcf. oem or its authorized dealers only to participate in the tender with documentary evidence. proof of procurement with test certificate to be submitted to consignee at the time of delivery. [ warranty period: 30 months after the date of delivery ]
Tender For supply & testing of street light panel range 6 kw, 3 phase, ip 54, frls, inbuilt short circuit pr otection, class h insulation confirms to is/iec 60947-4-1 time switch digital 24 hrs. 32 a tp contactor, 40a tpn mcb, hsn code 8537 with programmable time switch for slp, frame size -1 with all necessary access ories to complete the work in all respect. [ warranty period: 30 months after the date of delivery ]
Tender For drop out time delay relay for anti-skid true off delay control supply voltage 110-240 v ac/d c, place of installation s1k05 as per the switch board cabinet bill of material of rdso spec. no: rdso/pe/s pec/ ac/ 0184 - 2015 (rev-1) and rdso lr.no. el/7.1.108/mssbc, dt 17/09/21 to abb cat no: ct-ars.11s, siemens cat.no. 3rp25401aw30, carlo gavazzi cat.no. dbb02cm24, schneider cat.no. re22r2kmr, l&t c at.no. 23gdt0, dold cat.no. mk7873n, phoenix cat.no. etd-bl- 1t-230-pt and luetze only acceptable. [ warranty period: 30 months after the date of delivery ]
Tender For supply of street light panel range 6 kw,3 phase, ip 54, frls, inbuilt short circuit protection , class h insulation confirms to is/iec 60947-4-1 time switch astronomical 24 hrs. 32 a tp contactor, 40a tp n mcb , hsn cod e 8537 with astronomical time switch for slp, frame size -1 with all necessary assories t o complete the work in all respect . [ warranty period: 30 months after the date of delivery ]
Tender For supply of street light panel range 6kw, 3 phase, ip 54, frls, inbuilt short circuit protection, c lass h insulation, confirms to is/iec 60947-4-1 time switch digital 24 hrs. 32a tp contactor, 40a tpn mcb, hsn code 8537 with programmable time switch for slp, frame size 1, with all necessary accessories to co mplete the work in all respect. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above