Get complete information related to latest Inspection Cover Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Inspection Cover Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Inspection Cover Tenders.
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspectioncovers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspectioncovers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be
Tender For supply of inspectioncover for tr motor type 4303dy of demu/dpc as per drg. mo. -jmp/sk-4/12. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of inspectioncover small with packing for hitachi tm to drg.no.10 s 813-666a and 10 s 813-668 c. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of set of gasket for axle box inspectioncover of wag9/ wap7 locos as per drg. no. els/vskp/ 2017/18 each set consisting of [i] item no.1 - 04 nos [ii] item no. 2 - 8 nos. ]
Tender For 1 set contains: { i) 12 nos - oil seal part no: 26 ii) 12 nos - o-ring part no: 25 iii) 1 no- safety va , plunger, part no. 63, drawing no. : mgs-cst-006a of seal flushing pump 11/21- p-36a and b of carbamate , piston inspectioncover, part no. 24, drawing no. : mgs-cst-006a of seal flushing pump 11/21-p-36a~ b fo , drive pulley, part no. 11, drawing no. : mgs-cst-006a of seal flushing pump 11/21-p-36a~ b for carbama
Tender For supply of inspectioncover small with packing for hitachi tm to drg.no 10s-813-666a and 10s-813-668c [ warranty period: 30 months after the date of delivery ] ]
Tender For tender for supply of packing rubbers for grab handle and wheel chair and interior panels - packing grab pole ceiling 2thk , packing grab pole ceiling 3thk , packing grab handle wheel chair , packing bracket ceiling end 2thk , packing bracket side inspectioncover 4thk