Get complete information related to latest Inspection Covers Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Inspection Covers Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Inspection Covers Tenders.
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspectioncovers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspectioncovers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be
Tender For supply of ss wire netting size 6 mesh x 5 ft width x 33 ft length x 16 swg , ss wire netting size 08 mesh x 5 ft width x 30 ft length x 16 swg , ss wire netting size 14 mesh x 5 ft width x 30 ft length x 16 swg , ss wire netting size 16 mesh x 5 ft width x 30 ft length x 20 swg , ms expanded metal size 1 mesh x 5 width x22 length x 8 swg , brass suporting liner for flat bottom a c f machine of krupp make of 30 x48 capacity 750 kg charge 4 mesh x 160 long x 30 width x 16 swg , brass suporting liner for flat bottom a c f machine of krupp make of 30 x 48 capacity 750 kg charge 6 mesh x 160 long x 30 width x 16 swg , ss main liner for 30 x48 size krupp make flat bottom batch type c f machine for a massecuite length 160 x width 30 slotted , for 1750 kg charge a c f machine wil make brass 70 30 annealed working screen having thickness 0 point 55 mm to 0 point6mm and slot size as as 0 point 35mm x 4 mm
Tender For supply of spares for wm 18 rocket launchers c c - firing connector sub assembly , firing connector sub assembly spares , rear catch sub assembly spares , rocket presence switch sub assemblv , rocket presence switch sub assemblv spares , front catch release sub assembly , front catch release sub assembly spares , dummy rocket , straightness gauge , front catch testing set-up , oil iso vg 46 , inspectioncovers-muzzle and breech sides
Tender For work contract for carrying out cold air velocity test (cavt), supply & installation of expanded metal screen in boiler at unit no. 1 during aoh.
Tender For work of cold air velocity test (cavt) along with its design, manufacture and supply of expanded metal screen with fasteners & its installation at various locations in second pass of unit-7,250 mw boiler during aoh at bm-1, 250mw, tps, parli-vaijnath.
Tender For work of cold air velocity test (cavt) along with its design, manufacture and supply of expanded metal screen with fasteners & its installation at various locations in second pass of unit-7,250 mw boiler during aoh at bm-1, 250mw, tps, parli-vaijnath.
Tender For work of cold air velocity test (cavt) along with its design, manufacture and supply of expanded metal screen with fasteners & its installation at various locations in second pass of unit-7,250 mw boiler during aoh at bm-1, 250mw, tps, parli-vaijnath.