Get complete information related to latest Instrument Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Instrument Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Instrument Cable Tenders.
Tender For supply of 4 core, 0.75 sq.mm, highly flexible, screened control cable with pvc core insulation and robust, oil resistant outersheath, tinned-copper braiding, suitable for emc-sensitive environments, application range :- moving machines like crane festoon trolleys or drag chain assembly, technical specification:- (1) nominal voltage: iec u0/u: 300/500 v ul: 1000 v (2) test voltage: core/core: 4000 v core/screen: 2000 v (3) minimum temperature range: flexing: -5 deg. c to +70 deg. c (ul: +80 deg. c) (4)minimum bending radius: flexing: up from 10 x outer diameter fixed installation: 4 x outer diameter (5) conductor stranding: fine wire according to vde 0295 class 5/ iec 60228 class 5 or equivalent standards (6) no. of cores :- 4 (7) mm square per conductor :- 0.75 conforming to olflex chain 819 cp 4g0.75, article number:- 1027912 of make lapp (catalogue olflex chain 819 cp attached with demand for reference) accepted makes: lapp, helukabel, siemens and igus (india) pvt. ltd. [ warrantyperiod: 12 months after the date of delivery ] ]
Tender For bid to ras supply of instrumentation cables : : -two pairs 2p x 0 point 5 0 point 5 sq mm instrumentation cable , four pairs 4p x 0 point 5 0 point 5 sq mm instrumentation cable , eight pairs 8p x 0 point 5 0 point 5 sq mm instrumentation cable , twelve pairs 12p x 0 point 5 0 point 5 sq mm instrumentation cable , two triad 2t x 1 point 5 1 point 5 sq mm instrumentation cable , four triad 4t x 1 point 5 1 point 5 sq mm instrumentation cable
Tender For supply and installation of telecom and scada equipments for extending data connectivity to upcoming cgd hookups and lmc connectivity in southern region on annual rate contract basis - supply items under arc for telecom system, supply of mpls tp equipment, supply of ip/mpls type switch, supply of converter, ac-dc (230 v ac to 48 v dc), ac-dc (230 v ac to 24 v dc), dc-dc (48 v dc to 24 v dc), dc-dc (24 v dc to 48 v dc), supply of battery charger with battery backup, supply of porta cabin, supply of lct, supply of equipment racks, supply of solar panel with battery back up 300 w, supply of solar panel with battery back up 200 w, supply of solar panel with battery back up 50 w, supply of explosion proof telephone, supply of weatherproof telephone, supply of acoustic half hood booth, supply of multi-paired armoured cable (10 pair), supply of 6 twisted pair, 1.5 sq. mm ( 12 core ), individual pair andoverall aluminium mylar tape shielded with drain wire, supply of 6 twisted pair, 0.50 sq. mm ( 12 core ) individual pair and overall aluminium mylar tape shielded with drain wire, supply of telemetry interface cabinet (tic), supply of analog phones, supply of fxo gateway, supply of fxs gateway, supply of ethernet switch, supply of rtu, supply of mini rtu, supply of ftc, supply of joint closures, supply of ip camera, supply of spares for telecom, supply of spares for rtu, supply of ethernet to serial converter, supply of optical to serial convereter, supply of rs 232 to rs 422/rs485 converter, supply of optical to ethernet converter, supply of out door equipment panel, supply of field mounted enclosure conforming ip-66, supply of gprs modem, supply of atex switch 8 port, supply of 24f ofc cable, supply of rtu management licenses for makes like husky, schneider, etc, telecom system (works), installation of mpls/tp equipment, integration of mpls/tp equipment with existing nms, installation and commissioning of solar system, installation of porta cabin, laying and termination of multi-paired armoured cable (10 pair), installation and configuration of converter/switch and interfacing of same with flow computer and integration with scada system, installation of tic panel, design, engineering and submission of documents, testing of ofc and submission of reports, earthing works, installation testing & commissioning of instrumentation cable, installation commissioning and integration of rtus in existing scada server, installation commissioning and integration of mini rtus in existing scada server, installation and integration of ip cameras in existing server for each cameras, installation of gprs modems if supplied as free issue, extending of leased lines for 1000 km distance including modems (one ethernet interface & one e1 interface for lan) at both ends, rectification of ofc including supply of joint pit with identification of fault and testing of of cable, installation of outdoor panel, transportation charges for free issue material (per km rate to be quoted), laying of ofc through hdd method, laying of ofc through direct trench method, point to point radio communication (2.4/5.8 ghz licence free ism band), laying of ofc cable ( if ofc supplied as free issue by gail), blowing of ofc in duct, manday charges [post-installation manday charges for rtu/telecom works on an on-call basis, including troubleshooting, system calibration, software updates, configuration adjustments, and performance optimization. ], total amount excluding gst, gst (cgst&sgst/utgst or igst) in percentage (%) on net total amount