Tender For bid to ras bid to ras bid to ras bid to ras tender for supply of niv 280608 life plus lpm 403 - battery 12 v nimh 3800 mah , nibp cuff with two house pipe and shooulder fitting assy for finger check electronic digital bp recorder model rbp 9000 , air bag l 15 cm h 4 cm , air bag l 15 cm h 6 cm , rechargeable liion bty 72vdc 4400 mah , adaptor input 100 24 v acout put 12 v dc 2a , nibp cuff , power supply card , spo2 probe 1 cut 6 pin , thermal printer assy with wire connector size length 23cm width 105 mm , ecg cable 10 way , chest below electrode with limb clamps , display size l 13cm w 105 mm , ecg card size l 13cm and w 8 cm , ecg cable 10 way , chest bellow electrode complete set , key pad assy size l 16 cm and w 11 cm , main pcb with core pcb , data bus 40 pin
Tender For supply of supply and installation of digital smart board for teaching 75 inch interactive flat panel with 4k touch screen display,supply and installation of digital electronic podium,supply and installation of 47 inch computer desk with adujstable monitor stand,supply and installation lesson armless swivel tablet chair,supply and installation of blackout roller blinds for windows uv protection waterproof room darkening corded roll up and down blinds,supply and installation of chair mats for hardwood and tile floor large anti slip floor protector rug anti slip,supply and installation of vinyl frosted window self adhesive privacy glass film for window glass frosted glass,provision of lan io boxes,fitment of lan io boxes,provision of multipurpose power network sockets,fitment of multipurpose power network sockets,laying out and securing of network cable,provision of 3u rack,fitment of assembling of 3u rack,fitment of configuration of network switch,configuration of pcs with network switch
Tender For supply of fuse 15 amp,ignition key,electronic governor controller,dc power contractor 1 pole,charging alternator belt,dc load bleeder,diesel filter mico make type1,diesel filter mico make type2,cable electric single core,fuel pipe,fuse10 amp 12v,fuse 30 amp 24v
Tender For corrigendum : provn of icu, ot, hdu and allied ancillaries in mh ranikhet. - phase-i schedule a part-i (building work), construction of block of tech building for hospital icu, ot, hdu and allied ancillaries alongwith rcc covered ramp ( g+1) (rcc framed structure) , with permanent specification including plinth protection all as shown on drawings and as specified., construction of block of pump house (rcc framed structure) , with permanent specification including plinth protection all as shown on drawings and as specified., construction of under ground static water tank of capacity 100 kl, complete all as shown on drawings and as specified., schedule a part ii-a (internal water supply) for details refer sch a in pdf folder, schedule a part ii-b (internal water supply), s&f health faucet (abs body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and abs wall hook including making connections and fixed in position complete all specified and directed., s&f brass cp mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all specified and directed., s&f brass chromium plated angle valve, fancy type screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed., s&f brass chromium plated shower rose with 150 mm long cp shower arm 125 mm size revolving type suitable for 15 mm bore pipes, complete all specified and directed., schedule a part iii-a (internal electrification) for details refer sch a in pdf folder, schedule a part iii-b (internal electrification), m & l for point wiring using 1.50 sqmm size, pvc insulated, unsheathed 1100 volts grade, is-694 single core multi-stranded (frls-h) copper conductor cable in proper colour coding drawn into and including metallic rigid conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.6 mm thick pressed modular steel terminal box for mounting fittings i.e, modular switch / sockets incl cover plate with frame including one continuous run of pvc insulated (green colour) 1.50 sqmm size stranded frls-h copper conductor cable as in earth wire and connecting all metal parts to common earth dolly incl cutting and chases pinning in for concealed conduit wiring and making good of disturbed surface complete all as specified and directed for the following: -, note: (i) also includes inverter wiring with one run of inverter wire 1.5 sqmm all alongwith circuit also included. (ii) all items used should be isi marked. (iii) cutting chases for concealed type point wiring including making good the same with plaster/putty is deemed to be included in quoted rate by the contractor. (iv) accessories modular metal boxes, cover plate inner & outer is also deemed to be included in quoted rate., (a) one light point point /bell buzzer/ ceiling fan/exhaust fan point controlled by one-one way switch. ( 9 points for lift schedule), (b) one three pin 5 amp socket on same board with other switches., (c) one three pin 5 amp socket on independent board, (d) all as per item no 5.01 above but for two way wiring, (e) all as per item no 5.01 above but point wiring with cable 2.50 sq mm size, with earth continuity conductor of size 2.50 sq mm. ( 9 points for lift schedule), supply and fix high quility led t5 integrated batten tube light 20 watt with aluminium extrusion with frosted pmma/pc diffuser, internaly pre wired of 1.5 sqmm twin twisted flexible cable incl connection with ceiling rose all as specified & directed., supply and fixing led batten light fitting 20w, 220v,with microwave motion sensor based technology with aluminium housing & integrated electronic driver of make havells with cat part no lumilinesmart20wled865pcwh or equivalent make of bajaj/philips/crompton complete all as specified & directed., supply and fix led bulb 9 watt complete all as specified and directed., s & f mccb 4 pole 200 a,
Tender For dismantling installation commissionin testing and calibration of 60mt electronic road weighbridge by required spares along with conduiting of load cell cable by gi pipe and gi flexible at rajhara colliery under rajhara area