Tender For providing of custom bid for services - electrical annual maintenance contract skilled 104 no electrician required 24 x 7 and 365 days irrespective of sundays holidays,custom bid for services - transformer oil filtration,custom bid for services - transformer oil testing report,custom bid for services - relay testing,custom bid for services - braker service(acb and vcb),custom bid for services - thermography of panel,custom bid for services - tan delta of transformer,custom bid for services - testing of vcb bottle,custom bid for services - hiring of extra electrician skilled to be quoted as man days rate x qty x gst,custom bid for services - overtime per hour skilled qty x rate per man hour x gst,custom bid for services - cable excavation and backfilling
Tender For maintenance of electrical installation at cpnr building under sub division-i shimlasubwork/packages:repair/replacement of old unserviceable acb, batteries, strip light, gate light, downlighters, earth work and servicing and overhauling of amf and fire panel at phagli club
Tender For supply, installation, testing and commissioning of (a) four pole,1600 a acb of lt panel, (b) temperature scanner for dry type transformer, (c) feeder protection numeric relay for 11kv ht panel of the gangarampur ssh, dakshin dinajpur
Tender For bid to ras tender for supply of 22bslc002 spares of ventilation motor panel control acos galley equipment and master unit : : - switch tripple pole 400amps fuse switch unit , 63a size 000 din type fuse 160a fuse base , overload relay , door sealing frame for 3w series microprocessor based acb , circuit breaker 160a , 16a size 000 din type fuse , red normal actuator with plastic front ring with 2no 2nc rea , timer range 3 to 12 sec , contactor 30amps 2no 2nc coil voltage 110v , bimetal overload relay having relay range 70 95 with adapto
Tender For corrigendum : supply of and testing of 1600kva 33kv transformer for second year , servicing testing and calibration of numerical relays at 33kv ht panel for first year , servicing testing and calibration of numerical relays at 33kv ht panel for second year , servicing testing and calibration of auxillary relays for first year , servicing testing and calibration of auxillary relays for second year , providing lettering upto 50mm letter height , providing lettering excedding 50mm letter height but not excedding 100mm letter height , lifting and lowering of submersible pump set of upto 5 hp capacity , repairing servicing of submersible openwell borewell pumpset of capacity upto 3 hp , repairing servicing of submersible openwell borewell pumpset of capacity above 3hp upto 5hp , rewinding of submersible openwell borewell pumpset of capacity upto 3 hp , rewinding of submersible openwell borewell pumpset of capacity above 3hp upto 5hp , dismantling overhauling and servicing of all type of centrifugal pumpsets from 7.5 to 10 hp , dismantling the existing centrifugal pumpset and rewinding from 7.5 to 10 hp , fabrication and supply of stainless steel board with suitable ss stand of approx 4 ft height , providing and fixing danger plates made of 1.6 mm mild steel for hv of size 250 mm x 200 mm , providing and fixing danger plates made of 1.6 mm mild steel mv of size 200 mm x 150 mm , providing single line diagram on 5mm thick aluminium sheet in a0 size , supply and fixing of anti condensation panel space heater flat type of min 80 w , supply and fixing of anti condensation panel space heater jaali type of min 100 w , supply and fixing of capillary thermostat for panel space heater , suppy fixing wiring and programming of the microprocessor based intelligent apfc controller , fabrication supply and installation of wall mounted street light panel , supply and fixing of fire retardant electrically insulated synthetic mat suitable for 33 kv ac grade , supply and fixing of fire retardant electrically insulated synthetic mat for voltage not exceeding 3.3 kv ac , identifying detecting cable fault for lt cable , identifying detecting cable fault for ht cable 33kkv grade , dismantling of the faulty high bay led light fitting , installation testing and commissioning of repaired new led high bay light fittings , supply of following sizes isi marked frls pvc insulated single core 1.5 sqmm copper cable , supply of following sizes isi marked frls pvc insulated single core 2.5 sqmm copper cable , supply of following sizes isi marked frls pvc insulated single core 4 sqmm copper cable , supply of following sizes isi marked multicore frls pvc insulated 3core x 1.5 sqmm copper cable , supply of following sizes isi marked multicore frls pvc insulated 3core x 2.5 sqmm copper cable , supply of following sizes isi marked multicore frls pvc insulated 3core x 4 sqmm copper cable , supply of led batten light of 20w , supply of single phase wall mounted oscillating type fan with 3 blade , supply of single phase oscillating type pedestal fan with 3 blade , supply of shunt release coil for l and t make upower fp acb , supply of 3hp dol panel board pump starter , supply of heavy duty sealed maintenance free battery of 12v 180 ah , supply of heavy duty sealed maintenance free battery of 12v 18 ah , supply of heavy duty sealed maintenance free battery of 12v 7 ah , supply of heavy duty sealed maintenance free battery of 12v 2.5 ah , supply of 10 mtr led rope light with ip 65 protection , supply of constant current led driver of 36 watts , supply of constant current led driver of 60 watts , supply of constant current led driver of 120 watts //bid details 2 / 52 , supply of 12 feet height a type self supported foldable aluminium step ladder , supply of digital earth resistance tester , supply of artificial resuscitator , supply of single phase highly insulated frp earth discharge rods , supply of transformer oil conforming to is 335 , supply of silica gel crystals for po
Tender For (a) repairing/reconditioning of 01 no of 3.3 kv, 160 amp, 360 kw rated, sait teknik pvt. ltd. make dol starter, sl. no.-sahd-2723 installed at quarry no1(b) repairing/reconditioning of 01 nof lnt put make acb lt panel sl.no. lw00355 of pundi project
Tender For bid to ras supply of supply and fixing of 600amp isolator , providing and fixing of lt lug for outdoor cable end up to 25mm to 240mm , repair and maintenance of lt panel , service and repair ht 11 kv vcb , service and repair lt 800 amp 4 pole acb , provding and fixing of 4 pole mccb 320 amp 250 amp 150 amp 100 amp , supply of fire extinguisher 5 ltr capacity on substation , lt outdoor end terminal size 4x185mm , providing and fixing of change over up to 400 amp , providing and fixing 800 amp panel on substation , supply and laying of 4 core size 25 sqmm aluminium armoured cable , providing and fixing 200 amp panels with starter and 150 amp mcb , repairing of fault cable joints by high insulation rubber , supply of one core size25 sqmm copper cable , supply and laying of 4core size 185sqmm aluminium armouured cable , under ground cable fault locating machine at various places , providing and installation xlpe lt cable straight through joint size up to 3.5 core x 240 sqmm
Tender For tender for supply of panelrepair items patratu fgd : : - acb repair items_4000a (as per annexure-a) , acb repair items_800a (as per annexure-b) , acb repair items_1250a (as per annexure-c) , panelrepair items _fgd (as per annexure-d) , man-day charge_fgd (for items mentioned in annexure-a , b , c and d) , power contactor tips for 400 a