Tender For auction sale of depot miscellaneous scrap - p.l. no. 98327768 condemned and unserviceable dynamic braking fan motors without fan -vertical type ( in which four numbers top end shield is aluminium and remaining ten numbers ferrous ) of sorts and sizes , full , intact with copper coils, commutators and shafts . with / without bearings, brush holders ,bearing caps, terminal boards, wires , cables and other ferrous / nf attachments. . as is where is basis. total weight- 4290 kgs approximately for 14 numbers. rate per number should be quoted.
Tender For supply of ring tongue type copper terminal end 6 sq. mm insulated with metal reinforcement similar to jainson cat no-174729 e dia 6.4 mm. make dowells/jainson /chetna/kamlesh industries/ascon engineering or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of end / terminal bonds for siemens make audio frequency track circuit of size 18 meter suitable for track circuit ftgs 46 /917. terminal bond should be made of pvc coated wire rope of crosssection approximately to 240 sq. mm. pvc coated wire should be as per is:2266 of 1978 or latest and pvc sheathing should be of compound type 6 as per is:5831 of 1970 with latest amendment if any. reclaimed or recycled material shall not be used. brass lug should be brazed at both ends of terminal bond and brass terminal in centre of terminal bond as per sample and drawing. terminal bonds are to be fixed along the foot of rail in form of 'alpha' and both ends of brass lug are to be riveted or fixed with nut bolts with web of rail by copper rivets or nut -bolts after drilling holes. note-sample approval from consignee before bulk supply. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of end / terminal bonds for siemens make audio frequency track circuit of size 9 meter suitable for track circuit ftgs 46 /917. terminal bond should be made of pvc coated wire rope of cross section approximately to 240 sq. mm. pvc coated wire should be as per is:2266 of 1978 or latest and pvc sheathing should be of compound type 6 as per is:5831 of 1970 with latest amendment if any. reclaimed orrecycled material shall not be used. brass lug should be brazed at both ends of terminal bond and brass terminal in centre of terminal bond as per sample and drawing. terminal bonds are to be fixed along the footof rail in form of 'alpha' and both ends of brass lug are to be riveted or fixed with nut bolts with web of rail by copper rivets or nut -bolts after drilling holes. note-sample approval from consignee before bulk supply. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply and testing with end termination, intermediate termination and cord-end termination of over current protection system along with full end termination along with residual current protection operated on 415v ac supply with load current 100a, 4 pole conforming to is 12640 (part 2):2008 iec61009-1:1996 or latest with bimetallic terminal connector suitable for 4 dia aluminium tubular busbar for 100a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 4 sqmm confirming to is: 5561-1970 with maximum temperaturerise of 90 degree celsius. material shall be confirmed to designation a6 of is: 617-1959. breaking 1 resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 16 with earth leakage protection of 100 ma, with cord end termination suitable for copper cable of conductor size 1.5 sqmm with cord-end termination, manufactured out of ec grade aluminium extruded extensiontubes of minimum purity 99.5% and conductivity not less than 60% iacs, designed and fabricated strictly in accordance with is:5082 specifications, duly conforming in all respects to is:2121 part-i & ii and is:2544 with provision for sustaining continuous operating temperature up to 120 degree c under specified serviceconditions. [ warranty period: 30 months after the date of delivery ] ]
Tender For auction sale of depot non ferrous scrap - cond & u/s alu bronze scrap such as suspension clamp, direct clamp,suspension clamps, direct clamps, ending clamps, contact dropper clip, si a end and b end, catenary single suspension clamp, 95 sqmm catenary ending clamp, catenary ending clamp, 95 sqmm catenary wire splice, catenary splice, catenary wire ending clamp, contact wire splice, pg clamp 1031-2, pg clamp 1041-2, catenary wire splice, catenary ending clamp 65 sqmm, 65 sqmm catenary ending clamp, catenary suspension bracket hook, suspension clamp, catenary suspension clamp, large span wire ending clamp 130 sqmm, terminal connector, large suspension bracket, contact wire dropper clip, section insulator end splice fitting a end and b end, section insulator beam, contact wire parallel clamp, pg clamp 6171, pg clamps rt 1071, si a & b end, terminal to hitachi, ss wire rope ending clamps, tramway direct clamp, single suspension clamp, swivel clips, large catenary suspension bracket, contact wire swivel clips (pg clamp 1031-2, 1031-3, 1051-3), catenary suspension clamp and suspension bracket, catenary splice 65 sqmm. with avaialble ferrous/ non ferrous/copper attachements in as is where is condition. note: segregation and removal of any attachments is not permitted. pl no 98230086
Tender For : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of spares for diese
Tender For supply and testing with end termination, intermediate termination and cord-end termination of over current protection system along with full end termination along with residual current protection operated on 230v ac supply with load current 16a, 2 pole conforming to is 12640 (part 2) :2008 iec61009-1:1996 or latest with bimetallic terminal connector suitable for 2.5 dia aluminium tubular busbar for 16a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 2.5 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. material shall be confirmed to designation a6 of is: 617-1959. breaking 1 resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 16 with earth leakage protection of 30 ma, with cord end termination suitable for copper cable of conductor size 1.5 sqmm with cord-end termination, manufactured out of ec grade aluminium extruded extension tubes of minimum purity 99.5% and conductivity not less than 60% iacs, designed and fabricated strictly in accordance with is:5082 specifications, duly conforming in all respects to is:2121 part-i & ii and is:2544 with provision for sustaining continuous operating temperature up to 120 degree c under specified service conditions [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of ductable ac , installation , copper piping , pvc drain pipe , iron stand , ms cable tray , copper conductor cable , copper conductor cable 2 , sheet steel enclosure , plywood 12 , plywood 6 , providing and charging toping up refrigerant r-410a , supplying installation balancing and commissioning of fabricated at site gss sheet metal rectangular or round ducting complete , supplying and fixing of 9 mm thick cross linked polythyline xlp insulation for supply air duct , supplying and fixing of following ways surface or recess mounting, vertical type 415 v tpn mcb distribution board 8 way double door , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel , supplying and fixing 5 a to 32 a rating, 240 v 10ka c curve miniature circuit breaker , supplying and making end termination with brass compression gland and aluminium lugs for following
Tender For distribution transformer of rating 500 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, the type of tap changer for variation of hv voltage from +5% to -15% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, confirming to is 1180 (part 1): 2014with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 of is 1180 (part 1). terminal agreement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4 nos.) shall confirm to is 7421. suitable cable-end box along with cable entry hole glands is to beprovided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is 1180 (part 1) latest. (ii) routine test certificates as per is: 1180(part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d), (e) of is: 1180 (part 1) latest. [ warranty period: 30 months after the date of delivery ]