Web Analytics Made Easy - StatCounter

Insulated Conductor Tenders

Get complete information related to latest Insulated Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Insulated Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Insulated Conductor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45737026 Due date: 04 Aug, 202604 Aug, 2026 NA
Tender For supply of 6 quad cable 1.4mm dia copper conductor, polythene insulated aluminium screened, wire/strip galvanized steel,armoured, underground, jelly filled as per specification no.rdso/spn/tc/72/2007, amendment no.1 & 2 or latest (inspection : rdso) [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 2 %age , item category : special (signaling cables) , total po value variation permitted: not applicable ] ]

Central Government/Public Sector

CTN :45664895 Due date: 14 Jul, 202614 Jul, 2026 NA
Tender For corrigendum : supply of service connector of 2.5 sq.mm cross section for connecting railway carriage fan and light fittings as per item no.wago make or equivalent as per the technical data: (1) type of wiring: side-entry wiring. (2) total number of connection points: 2. (3) total number of potentials: 1. (4) connection technology: cage clamp. (5) actuation type: push-in. (6) connectable conductor material: copper.(7) solid conductor: 0.5 - 2.5 mm 2/20 - 16awg. (8) fine stranded conductor: 0.5 - 2.5 mm 2/20 - 16awg. (9) strip length: 9 - 11mm/ 0.35 - 0.43 inch. (10) width: 8mm/ 0.315 inch. (11) height: 15.5mm/ 0.61 inch. (12) depth: 42 mm/ 1.654 inch. (13) colour: grey. (14) fire load (mj): 0.099 (mj). (15) weight(g): 5(g). [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45727776 Due date: 31 Jul, 202631 Jul, 2026 NA
Tender For corrigendum : supply of isi marked 11 kv (e) grade 3core 240 sq.mm. ) ht cable stranded compacted circular aluminium conductor screen semi conducting compound xlpe insulated, insulation screening with extruded semiconducting compound in combination with copper tape, cores laid up inner sheath of pvc, galvanized steel flat string armored and overall pvc sheathed cable confirming to is: 7098(part 2):1988 with amendment number 1 and 2 and 3 reaffirmed 2005 & improved fire retardant features as category c2 fr-lsh type. (3) cable is not use for mines & low voltage application. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45731699 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For supply of e-beam irradiated thin walled flexible elastomeric cross linked cable with copper conductor , size 120 sq.mm, 1.8 kv grade conforming to rdso / spec.no.elrs / spec /elc/ 0019 (rev. 4) feb.2018 for rolling stock application. note:- 1). dealers should attach valid dealership certificate from the oem along with the offer. 2). manufacturers should indicate theiridentification mark, month and year of manufacture at a suitable location by using a suitable method without affecting the performance of the product.3) offers of rdso approved vendors only will be accepted. [warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45736404 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For supply of single core electron beam irradiated cable with copper conductor of size 0.5 sq. mm, 300 / 500 v ac, confirming to clw specification no. clw/es/3/0458, alt. e. the cable shall be supplied in red and black colour only. [ warranty period: 12 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45737352 Due date: 21 Jul, 202621 Jul, 2026 NA
Tender For supply of single core thin walled electron beam irradiated copper cable, size 2.5 sq mm,with copper conductor, working voltage above 750v & up to 1.8/3.0 kv, suitable for use in rolling stock application, as per rdso specification no elrs/spec/elc/0019 (rev-4) of feb- 2018. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted:max 8 lacs ] ]

Central Government/Public Sector

CTN :45726534 Due date: 21 Jul, 202621 Jul, 2026 25.00 Lacs
Tender For repair/replacement of e/m items and rewiring in md and otm accn at 7a area, 161 mh, asc, mes ib, devkatiya and connected area at mil stn pithioragarh under ge (mes) pithoragarh - description of items, taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and removing material for taking credit (credit for material should be made as per condition sepretly) and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified., taking down switches, socket, ceiling roses, pendants, regulators, sockets, holder, bell, bell push etc any type. all as specified and direct., m&l for point wiring for one light point/fan/bell point controlled by one switch with 1.5 sqmm pvc insulated unsheathed copper conductor single core multi strand flexible cable frls with proper color coding and 1.5 sqmm pvc insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid pvc conduit medium grade size 20 mm dia or higher with all fittings (isi marked) controlled by one switch including ci/ms sunk box for piano type wiring or metal flush box for modular wiring of required size & as directed & 3 mm thick plastic laminated sheet for piano type wiring or cover plate for with frame modular type, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified., m&l for point wiring for one light point controlled by two way switches with 1.5 sqmm pvc insulated unsheathed copper conductor single core multi strand flexible cable frls with proper color coding and 1.5 sqmm pvc insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid pvc conduit medium grade size 20 mm dia or higher with all fittings (isi marked) controlled by one switch including ci/ms sunk box for piano type wiring or metal flush box for modular wiring of required size & as directed & 3 mm thick plastic laminated sheet for piano type wiring or cover plate for with frame modular type,including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified., all as per srl item no-2 here in above but point wiring in replacement for one 3 pin 5/15 amps socket outlet independent with 2.5 sqmm pvc insulated unsheathed copper conductor single core multi strand flexible cable frls with proper color coding and 2.5 sqmm pvc insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit., all as per srl item no-2 here in above but point wiring in replacement for one 3 pin 15 amps socket outlet independent with 4 sqmm pvc insulated unsheathed copper conductor single core multi strand flexible cable frls with proper color coding and 4 sqmm pvc insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit., all as per srl item no-2 here in above but point wiring in replacement for for one 5a socket outlet on the same board with 1.5 sqmm pvc insulated unsheathed copper conductor single core multi strand flexible cable frls with proper color coding and 1.5 sqmm pvc insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit controlled by one switch, m&l for point wiring for one light point/fan/bell point controlled by one switch with 1.5 sqmm pvc insulated unsheathed copper conductor single core multi strand flexible cable frls with proper color coding and 1.5 sqmm pvc insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in pvc casing & caping of size width 25 mm x hight 16 mm or higher with all fitting

Central Government/Public Sector

CTN :45707591 Due date: 15 Jul, 202615 Jul, 2026 30.00 Lacs
Tender For repairing replacement of internal wiring fitting and fixture and various type of led fitting and connected earthing items at domestic area at af stn naliya - materila and labour for point wiring with 1.5 sq mm frlsh single core pvc insulated unsheathed 1100 v grade with multistranded copper conductor drawn through pvc casing and capping with all accessories fixed to wall froofs ceiling etc and incl provision of 1.5 sq mm pvc insulated and unsheathed copper conductor as earth continuity conductor and connected to common earth dolly including pvc box isi marked of suitable size for mounting the switches, socket outlets, fan regulators etc., complete all as specified and directed for following:- one light/fan point controlled by one switch. one socket 3 pin outlet 5 amp on independent board. one light point controlled by two 2-way switches. one 3 pin socket outlet 5 amp on the same board with other switches. one bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size. all as per serial item number 2.00 here-in-before but with copper conductor cable of 2.5 sqmm size for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm copper cable as earth continuity conductor. supply and fix in replacment of switch piano flush type single pole one way 5 amp, complete all as specified and directed. supply only socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed. supply only socket outlet multipurpose 213 pin 5 amps flush button type with universal box in polycarbonate complete all as specified and directed. supply only switch socket multipurpose 2 in 1,5 and 15 amps complete all as specified and directed. supply only ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed. supply only switch bell push, flush type 5 amp. supply only electric bell ding-dong ac 230 volt sp with brass screws and cup washers all as specified and directed. pa supply only hylem sheet 3 mm thick size 9" x 11" including cutting of switch,socket complete all as specified supply only hylem sheet 3 mm thick size 8" x 5" including cutting of switch,socket complete all as specified supply only mcb single pole and neutral 32-63 amps, 240 volts, complete all as specified and directed. all as per item ser no 60 above but with two run of single core 6 sq mm and one run of 6 sq mm frlsh as earth wire s&f in replacement of 9 watt led bolard lights 4300/6500 k in rectangular shaped victorian design with opal acrylic diffuser and ip 65 protection,including pcc work for mounting the fittings with suitable size of nut, bolts and connection with two core copper cable all as specified and as directed. make bajaj, havells, crompton. m&l for repair / maint of wooden/steel boards for electrical db of any type and size including replacement of doors as per site requirement, hinges, handle and locking arrangement with necessary welding works, wooden works to make good the wooden / steel boards including painting with synthetic enamel paint of one coat all etc complete. the quoted shall be inclusive of replacement of wooden doors! steel doors/hinges! locking system/welding work required for repair/fixing of new doors etc complete pac s&f in replacement of 36w led recessed 2x2 luminaire 6500k fixed in the existing ceiling/roofs white powder coated crca housing with led seanless front frame with flat white transmission acrylic cover and necessary connection with twin core copper cable of suitable size in kutch auditorium with ceiling height of more than 20 feet including necessary arrangement for scaffolding ladder for replacement of ceiling lights all as specified and as directed. note: the quoted rates are inclusive of necessary safety arrangements iscaffolding/ladder etc complete all as specified and directed

Central Government/Public Sector

CTN :45709067 Due date: 18 Jul, 202618 Jul, 2026 45.00 Lacs
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be

Central Government/Public Sector

CTN :45719686 Due date: 13 Jul, 202613 Jul, 2026 44.90 Lacs
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
 Loading, Please wait...

Connect us via What's Up