Get complete information related to latest Insulating Bush Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Insulating Bush Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Insulating Bush Tenders.
Tender For miscellaneous items for hpb and liver transplant surgery ot - radiopaque gauze :-should be sterile gauze & made up of 100% cotton gauze fabric type ep 17- x ray detachable should be weaved x ray 100% barium sulphate or metal it should be lint free, non irritating, latex free, and tissue size:- 10*10 cm*12 ply lint free non pack size 1*4 pc., vircyl sutupac 1, 1-0, 2-0 ,3-0 ,4-0, cautery pincil size 9 , electro surgical cautery tip cleaner, micro suction tip canula, liver biopsy gun, c. arm camera cover, usg prob cabel and camera cover, trolley covers, mayo trolley covers, pounch- opsite drap pouch drape:- 2 incise film provides continuous broad-spectrum antimicrobial activity to help reduce the risk of surgical site contamination incise drape adheres to the operative site, creating a sterile surface at the beginning of surgery 360-degree pouch provides optimal fluid collection to minimize contact with fluid and helps reduce the risk of contamination to or team pouch allows for easy clean-up and saves time comes with tube and cord organizers. a clear, plastic, 360-degree fluid collection pouch with tube and cord organizers. size 30*30 cm, steridrip (basic surgical pack), inj. methylene blue 1.0% 10ml ampoule, inj. albumin 5% (100ml), inj. calcium chloride (100 mg/ml), inj. diltiazem (5 mg/1ml, inj. phenylephrine (10mg/1ml) in ampoule size, inj. dns 500ml (double layered sterile plastic polybag), inj. dns 500 ml ( in sterile double layered sterile plastic polybag), inj. ns 500 ml (in sterile double layered sterile plastic polybag), inj. ns 500 ml (in sterile double layered sterile plastic polybag), inj. ns 1000 ml (in sterile double layered sterile plastic polybag), inj. ns 1000 ml (in sterile double layered sterile plastic polybag), 0.33 ns (double layered sterile plastic polybag), 0.33 dns (double layered sterile plastic polybag), 3% ns (double layered sterile plastic polybag), inj gelofusion 500ml, single arterial & cvp pressure transducer ( compatible with edwards continuous cardiac output monitor ) one disposable pressure transducer having gold plated connector tip for best signal quality with flush device & vent stopcock, iv set, 2 three way stopcocks it should have special hood to reduce contamination risk. gold-plated connector wires for high-fidelity signal transmission. available with a snap-tab flush device that can be easily gripped and stretched 360 to quickly and easily flush the system and generate a square-wave test pattern. it should have a flow rate of 3 +/- 1 ml/hr under 300 mm hg iv bag pressure. should be usfda approved., arterial catheter 3fr-l-8cm usfda approved, gamjee roll, ky jelly, l-70 for fluid warmer set, d1-100 tubings for rapid fluid transfusion, hd catheter (size : 11.5 | 8.5 | 9 | 9.5 |10 | 10.5 ), et tube with suction port (size : 7 | 7.5 | 8 | 8.5), single pressure transducer with closed blood sampling system adult(vamp kit) one disposable pressure transducer having gold plated connector tip for best signal quality with flush device & vent stopcock, iv set, 1 shutoff valve, 60 patient pressure tubing along with inbuilt inline 12 cc reservoir & 2 self-sealing z-site sampling ports located 13 and 55 from patient for closed blood sampling; pole mountable. it should have special hood to reduce contamination risk. gold-plated connector wires for high-fidelity signal transmission. available with a snap-tab flush device that can be easily gripped and stretched 360 to quickly and easily flush the system and generate a square-wave test pattern, patient dress anti-bacterial ,anti-virus and anti-fungi :- fabric should be effective against bacteria , viruses, fungi, absorbency factor of less than 1 sec as per aatcc-79.has moisture wicking factor of 5 sec as per aatcc 197, fabric made up of 94% polyester ,6% spandex and 180 gsm +/-5% , free from toxin substances , breathable , skin friendly, antiseptic property ,should be iso 13485, cdsco & ce approved. size :- small to xl, pressure
Tender For supply of air filter cartridge v 13 , tank water reserve , head lamp f-8043900 6220-004178 , horn assy high , arm assy wiper lh , adjustable spanner 200 205 mm , rear view mirror , lens back up lh , handle lock , oil seal , bush sprg shackle , relay turn signal , minor rep kit for clutch m cyl consisting , minor rep kit for clutch m cyl consisting of , knob , gasket
Tender For supply of point insulation complete set as per rdso/spn/168/2005 revision 2.0 or latest for 1.switch bracket d bracket insulation for irs point machine - one set comprises of (a)side plate lh to drg.no. s-3266 - 1 no. (b) side plate rh to drg.no. s-3265 - 1 no. (c)insulatingbush to drg.no. s-23199 - 4 nos. (d) insulating washer to drg.no. s-8640 - 4 nos., 2. split-stretcher bar 2.1 insulation for leading stretcher bars (bg) each set comprising of (a) insulating plate for leading insulated stretcher bars bg as per rdso drg.no. t-10384 -2 nos. (b) insulatingbushing for leading insulated stretcher bars for bg as per rdso drg.no. t-10368- 4 nos. (c) insulating washer for insulated stretcher bar bg as per rdso drg.no. t-10371 - 6 nos. 2.2 insulation for following stretcher bars bg. each set comprising of: (a)insulating side plate for insulated stretcher bars bg as per rdso drg.no. t-10367 -3 no. (b) insulatingbushing for insulated stretcher bars bg as per rdso drg.no.. t-10368 - 6 nos. (c)insulating washer forinsulated stretcher bars bg as per rdso drg.no. t10371 - 12 nos & 3. gauge tie plates (52 kg/60kg as per site requirement) insulation for (bg) complete with insulatingbush and washer each set comprising of: (a) insulating plate for insulated tie plate bg as per rdso drg.no. t-10372-1 no. (b) insulatingbushing for insulated stretcher bar bg as per rdso drg.no. t10368 - 3 nos. (c) insulating washer for insulated stretcher bar bg as per rdso drg.no. t-10371 - 6 nos. spec:rdso/spn/168/2005 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For tender for supply for transformer ht flexible insulatingbushing boot guard for prevention against animals & bird fault, rain water fall inside the transformer
Tender For supply of set of insulatingbush 08 x 10.00 high insulation hard epoxy fibre for temperature sensor assembly of traction motor type 6fra6068. as per clw drg. no- 4twd.096.163, alt-4 or latest ref.-03. each set consisting of 01 item 02 nos only. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]