Web Analytics Made Easy - StatCounter

Insulation Foam Tenders

Get complete information related to latest Insulation Foam Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Insulation Foam Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Insulation Foam Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Corporations/Associations/Others

CTN :45721980 Due date: 06 Jul, 202606 Jul, 2026 10.00 Lacs
Tender For motor and pump maintenance along with material supply for bhor municipal council - rewinding of different capacity motors, 90 h.p, 60 h.p, 50 h.p, 25 h.p, 12.5 h.p, 10 h.p, 7.5 h.p, 5 h.p, 2 h.p, supply of bearing no. 6318, supply of bearing no.7322, supply of bearing no. 6316, supply of bearing no.7320.13, motor dismantling and repairingand erection, 90 h.p, 60 h.p, 50 h.p, 25 h.p, 12.5 h.p, 10 h.p, 7.5 h.p, 5 h.p, 2 h.p, repairing of 90 hp v.t. pumps -dismantling and repairing and erection of following capacity v.t. pumps with bowl assembly , column pipe ,shaft, bearing ,bushing as par sapplied including all cost of skilled labour, transportation, loading unloading and all applicable taxes (old scrap material should tekan by contractor and cost of scrap should deduct and final offer should quote), repairing of 60 hp v.t. pumps -dismantling and repairing and erection of following capacity v.t. pumps with bowl assembly , column pipe ,shaft, bearing ,bushing as par sapplied including all cost of skilled labour, transportation, loading unloading and all applicable taxes (old scrap material should tekan by contractor and cost of scrap should deduct and final offer should quote), supply of various parts for 90 h.p pump stuffing box bronze bushing., supply of various parts for 90 h.p pump gland sleeve s/s material., supply of various parts for 90 h.p pump top bowl repair with providing and welding of m.s. flange heavy duty with required sundry etc., supply of various parts for 90 h.p pump column pipe repair with welding if ribs m.s. flange with machining etc., supply of various parts for 90 h.p pump rubber bush, supply of various parts for 90 h.p pump shaft sleeve s/s material, supply of various parts for 90 h.p pump providing and fixing special strengthening heavy duty nut bolts., supply of various parts for 90 h.p pump rubber packing (chanmpion), supply of various parts for 90 h.p pump neck ring brass., supply of various parts for 90 h.p pump bowl bush rubber., supply of various parts for 90 h.p pump bowl bush brass., supply of various parts for 90 h.p pump impeller., supply of various parts for 90 h.p pump impeller turning, supply of various parts for 90 h.p pump spider bushing, supply of various parts for 90 h.p pump bowl assembly fitting, tafflon gland, supply of various parts for 60 h.p pump stuffing box bronze bushing., supply of various parts for 60 h.p pump gland sleeve s/s material., supply of various parts for 60 h.p pump top bowl repair with providing and welding of m.s. flange heavy duty with required sundry etc., supply of various parts for 60 h.p pump rubber bush, supply of various parts for 60 h.p pump shaft sleeve s/s material, supply of various parts for 60 h.p pump providing and fixing special strengthening heavy duty nut bolts., supply of various parts for 60 h.p pump rubber packing (chanmpion), supply of various parts for 60 h.p pump neck ring brass., supply of various parts for 60 h.p pump bowl bush rubber., supply of various parts for 60 h.p pump bowl bush brass., supply of various parts for 60 h.p pump impeller., supply of various parts for 60 h.p pump impeller qualate., supply of various parts for 60 h.p pump spider bushing, supply of various parts for 60 h.p pump bowl assembly fitting, repairing of starter, rewinding of 90 h.p. starter trasformer capacity with f class copper wire insulation including air drying ,varnishing with dr. bake warmish, backtoling, including all cost of skilled labour, dismantling trasformer transportation , loading, unloading, erection, and giving trial and testing and applicable of all taxes. (old scrap material should tekan by contractor and cost of scrap should deduct and final offer should quote.), rewinding of 60 h.p. starter trasformer capacity with f class copper wire insulation including air drying ,varnishing with dr. bake warmish, backtoling, including all cost of skilled labour, dismantling trasformer transportation , loading, unloading, erection, and giving trial and

Central Government/Public Sector

CTN :45719686 Due date: 13 Jul, 202613 Jul, 2026 44.90 Lacs
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl

Central Government/Public Sector

CTN :45713891 Due date: 20 Jul, 202620 Jul, 2026 20.00 Lacs
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

corporations/Associations/Others

CTN :45721429 Due date: 04 Jul, 202604 Jul, 2026 1.90 Lacs
Tender For for the safety of kavand passengers, repair of 11 gw 33 gw pure power line and temporary barricading of transformers, repair of green wires and bent poles and plastic insulation on iron poles for the safety of kavand passengers in the area of power distribution sub-division, nagal, under the power distribution division, devbad. the work of installing tar and reflected tape

corporations/Associations/Others

CTN :45721536 Due date: 04 Jul, 202604 Jul, 2026 1.90 Lacs
Tender For under the power distribution division of devbud, in the area of power distribution sub-division of devbud i and talheri buzurg, for the safety of kavand passengers, repair of 11 gw 33 gw pure power line and temporary barricading of transformers, repair of green wires and bent poles, and laying of plastic insulation on iron poles. work of installing concrete and reflected tape

corporations/Associations/Others

CTN :45721544 Due date: 04 Jul, 202604 Jul, 2026 1.70 Lacs
Tender For for the safety of kavand commuters, repair of 11 gw 33 gw electric power line and temporary barricading of transformers, repair of green wires and bent poles, and plastic insulation on iron poles for the safety of kawand passengers in the area of power distribution sub-division deobad ii (rural) under the power distribution division of devbud. work of installing ¼ glass cover sheet and reflected tape.

State Government

CTN :45732614 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For tender for thermal insulation for a/c ducting and minor repair work in ahus at terrace floor ahu room, cif, iiser campus, thiruvananthapuram

Central Government/Public Sector

CTN :45739677 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; cold insulation of liquid and vapour ammonia pipelines with cast in-situ puf insulation and 22 swg aluminium cladding in ammonia plant at rcf thal; servic..

CTN :45358214 Due date: 13 Jul, 202613 Jul, 2026 18.60 Lacs
Tender For corrigendum : tn-18368 supply of various electrical items at kstps, kota - supply of 3 phase, 415v lt motors for unit #1 to 7 at kstps, kota., supply and retrofitting of oltc of unit auxiliary transformer-4b at kstps, kota., supply of conveyor carrying idler frame & carrying idler frame troughing trainer for conveyor system in chp area., supply, installation, testing & commissioning of vaccum type gaseous chlorinator system capacity up to 20kg/hr with all accessories for pre treatment plant clarifier-iii for u# 6 & 7 of kstps, kota., supply of submersible dewatering/ mud pumps for cw, bcw & dmcw area of kstps, kota. kst, supply of middle collectors (laterals/intrabed distributors) for strong acid cation vessels of dm plant, stage-ll, kstps, kota., supply of various electrical items at kstps, kota., supply of portable and trolley mounted fire-extinguisher of different capacities for first-aid fire fighting system (extinguisher) installed at kstps, kota., supply of valves at kstps, kota., supply of misc. rubber items at kstps, kota., repair/machining of components of turbine & auxiliaries of unit 1 to 7 of kstps, kota, online helium leak detection test of condenser vacuum zone of unit # 1 to 7 (stage i to v) of kstps, kota, day to day joinery works inside & outside plant site, kstps, kota, capital, routine & breakdown maintenance of c&i instruments and equipments of stage-i to v, analyser, dm plant, clarifier, ics and cctv systems at kstps, kota., annual rate contract for 6.6kv vpi and non vpi ht motor rewinding from 175 kw to 4000 kw with new coils of insulation class 'f' and other additional works of stator and rotor.
 Loading, Please wait...

Connect us via What's Up