Get complete information related to latest Insulation Material Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Insulation Material Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Insulation Material Tenders.
Tender For supply of self adhesive insulationmaterial size 20x1250x1250mm, as per drawing/specific ation: mdts-116 revision 05. [ warranty period: 30 months after the date of delivery ]
Tender For supply and commissioning of hydraulic insulator testing jig for tensile load testing of 2 5 kv porcelain and composite insulators as per rdso spec.ti/spc/ohe/instent/0090(02/2009)rev.0 with a&c slip no.1(10/16)or latest. make/ brand : concord control systems limited or similar. [ warranty period: 30 months after the date of delivery ]
Tender For supply of porcelain sectioning insulator for section insulator assembly ri no. 6110 (cd 1050) as per rd so specification no.ti/spc/ohe/ins/0071 or latest. make/brand : iec, sgel or similar. [ warranty period: 30 months after the date of delivery ]
Tender For auction sale of 120 kn porcelain disc insulator,scrap insulating oil (without drums),scrap 315 mva ict along with associated accessories, as per annex.
Tender For supply of 1.5 sqmm single core frlsh copper wire, d type insulation, is;694:2010 latest, isi marked, c onductor material class 5 as per is:8130 latest. insulationmaterial as per is:5831 latest, colour of core-red , material of conductor plain copper, availability, of type test report from govt. lab/nabl/ilac ]
Tender For corrigendum : supply and application of insulationmaterials on pipe, equipment for part a and part b as per standard specification by providing all required materials in connection with the composite work for setting upof hpg-2, butene-1 and psa units atlepetkata - legends / notes for insulation workstypes of insulation : ih = insulation for heat conservation it = insulation for steam traced lines is = insulation for personal safety ic = cold insulation for anti-condensation ie = insulation for electrically traced lines ij = insulation for jacketed lines ik = insulation for dual insulated lines basic line surface materials : cs = carbon steel (including lt carbon steel), as = alloy steel, ss = stainless steelnotes :1. for insulation type it,tracer size and tracer numbers shall be as per specification.2. insulation thickness for ic where insulationmaterial is poly urethane foam (puf) / poly isocyanurate (pic) + cellular glass includes outer layer of 50mm of cellular glass and inner layer of balance thickness of puf/pic.3. insulation for ie consists of inner layer of rockwool and outer layer of puf / pic. the thicknesses have been specified as thk(i) and thk(o) for inner and outer layers respectively., part a, hot insulation (units)providing thermal insulation including supply of all insulating and ancillary materials, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required, including transportation of materials to work site, duly inspected by 3rd party inspector(llyods/bv/dnv or any other client approved party) at manufacturers shop & sample check/inspection at site by eil construction inspector, applying insulation on surfaces as specified including all preparatory work there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with sheet cladding as per spec. , providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions of engineer-in-charge. (refer legend for applicable eil specification), insulation type : ih ; surface material : cs & as ; operating temp. range : upto 125 (deg c) ; insulationmaterial : rockwool, pipes, nb 00.75 inches; thickness 25 mm, nb 01.00 inches; thickness 25 mm, nb 01.50 inches; thickness 25 mm, nb 02.00 inches; thickness 25 mm, nb 03.00 inches; thickness 25 mm, nb 04.00 inches; thickness 25 mm, nb 06.00 inches; thickness 25 mm, blind flange assemblies, nb 00.75 inches; thickness 25 mm, nb 02.00 inches; thickness 25 mm, valve assemblies, nb 00.75 inches; thickness 25 mm, insulation type : ih ; surface material : cs & as ; operating temp. range : 126 (deg c) to 350 (deg c) ; insulationmaterial : rockwool, pipes, nb 00.50 inches; thickness 25 mm, nb 00.50 inches; thickness 40 mm, nb 00.75 inches; thickness 25 mm, nb 00.75 inches; thickness 40 mm, nb 00.75 inches; thickness 50 mm, nb 01.00 inches; thickness 25 mm, nb 01.00 inches; thickness 40 mm, nb 01.00 inches; thickness 50 mm, nb 01.50 inches; thickness 25 mm, nb 01.50 inches; thickness 40 mm, nb 01.50 inches; thickness 50 mm, nb 02.00 inches; thickness 25 mm, nb 02.00 inches; thickness 40 mm, nb 02.00 inches; thickness 50 mm, nb 02.00 inches; thickness 65 mm, nb 03.00 inches; thickness 25 mm, nb 03.00 inches; thickness 40 mm, nb 03.00 inches; thickness 50 mm, nb 03.00 inches; thickness 65 mm, nb 04.00 inches; thickness 25 mm, nb 04.00 inches; thickness 40 mm, nb 04.00 inches; thickness 65 mm, nb 06.00 inches; thickness 40 mm, nb 06.00 inches; thickness 65 mm, flange assemblies, nb 01.50 inches; thickness 25 mm, nb 01.50 inches; thickness 50 mm, nb 02.00 inches; thickness 25 mm, nb 02.00 inches; thickness 40 mm, nb 02.00 inches; thickness 50 mm, nb 03.00