Get complete information related to latest Insulation Plate Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Insulation Plate Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Insulation Plate Tenders.
Tender For supply of 10.0 sq. mm. , frls, 3-core hrpvc flat cable, copper conductor with pvc insulation and sheath for working voltages up to and including 1100 volts three core, stranded pvc, type c heat-resistant cables (hr) as per is 5831 latest, type st2 cables sheathed with 85 degree celsius hrpvc compound to is 5831 latest, flexible isi marked cable with flexible ec grade copper conductor wire for submersible pumps as per is:694:2010 or latest. make: havells/polycab/finolex/nicco/ajanta/apar/kei
Tender For supply of hoppes 9 gun bore cleaning solvent , anti static esd safe heat insulation silicone magnetic solvent , stanley multipurpose tool bag , multiple drawers for small parts storage 18 drawers , 376 steel oil can
Tender For bid to ras providing of customized amc/cmc for pre-owned products - customized amc/cmc for pre-owned products - galley equipment; various brand; comprehensive maintenance contract (cmc); 24 hour response; yes--work for contract for annual maintenance contract of galley equipment at ins pallava-1. the contractor shall carry out preventive maintenance of the following, equipment every quarter: -, 1.1. cooking & heating equipment: -, - ss bme 304 grade hot bain marie, - electric hot plate (galley & wr), - 5 burner gas range (120"30"24"), - 2 burner gas cooking range with storage platform, - semi-automatic bench type industrial oven (3 deck), - electric griller chicken, - microwave oven / lg 30 ltrs mc 808, - food storage heating element electric with 04 containers (6kg, 304, grade ss), tasks:, - cleaning of heating surfaces and trays, - inspection and calibration of thermostats (half yearly), - checking and tightening of electrical terminals, - replacement of heating coils, knobs, and switches if required, - inspection of insulation and safety cut-off systems, - cleaning of exhaust vents and heat dispersion units, page 5 of 10, 1.2. mixing & processing equipment: -, - domestic blender/dough kneader sbwg 1500 watt 40 kgs, - cast iron commercial mixer 5 ltr, - wet grinder 10 kg cap, - pulvariser machine with stand, - vegetable cutting machine (up to 200 kgs), - potato peeler automatic 1.5 kw, tasks:, - cleaning of blades, jars, and grinding surfaces, - lubrication of moving parts, - inspection of motor windings and bearings, - calibration of speed controls, - replacement of belts, couplings, and safety covers, 1.3. refrigeration & cooling equipment: -, - ss icecube machine, - microwave oven, tasks:, - cleaning of condenser coils and drip trays, - checking refrigerant levels and gas charging (if required), - calibration of thermostats (half yearly), - inspection of compressors and insulation, - replacement of filters and seals, page 6 of 10, 1.4. exhaust & ventilation systems: -, - exhaust system for gas range, - exhaust hood with filter box and accessories, - 5 hp motor blower, tasks:, - cleaning of filters and ducts, - inspection of motor and fan bearings, - tightening of electrical connections, - replacement of worn-out belts and blades, - checking airflow and suction capacity, 1.5 cleaning & hygiene equipment: -, - wet and dry duty cleaning industrial vacuum cleaner 220smvco1, - commercial dishwasher with dryer model deb424fp, tasks:, - cleaning of filters and tanks, - inspection of pump and motor assemblies, - descaling of internal components, - replacement of hoses, nozzles, and seals, - electrical safety checks, 1.6. lpg gas system, page 7 of 10, 2. defect rectification of all machines including replacement of defective parts., 2.1 all replaced parts/compounds should be branded make and should have a, guarantee of one year from the date of renewal., 2.2 the contractor is required to attend the defect within 24 hours of reporting the, defect through telephone., 2.3 spares using for maintenance of equipment should be the oem make., 2.4 repairs / replacement of any items should be carried out as per the actual site, requirement / technical necessity., 2.5 rate quoted is inclusive of all taxes, freight charges, packing charges, spares,, transportation, service charges etc., 3. comprehensive coverage includes, - free overhauling: as per unit requirement., - free spares: due to wear and tear during contract period., - free labour: for all listed equipment., - free electrical wiring: internal wiring repairs., - free fan motor repairs: including winding and bearing issues., - free chemical washing: during overhauling., - free transportation: for off-site servicing., - free compressor & gas charging: for refrigeration units.,
Tender For supply of spares for elc 50c machine d d - indicating lamp 230v elc and lvdh green , indicating lamp 230v elc and lvdh amber , high temp. insulationplate set-50c , lvt 415v 3ph 50c 25a 8lp r10 r25 r50 r100 c1 , hvt indian type 50 high voltage transformer , limit switch for all elc except 8lp for elc 50c , high temp ss electrodes plate , timer for 110v 220v panel , hose 17 inch ss 3 4 bsp f conn both side for 50c u , castor wheel nylon 4 inch back castor wheel , castor wheel nylon 4 inch front castor wheel , collector 50c b1 , hose pipe ss set , o ring for top cover
Tender For corrigendum : supply of drone parts - drone miscellaneous with 5 accessories , anti static heat insulation with 16 accessories , rajshri soldering paste with 4 accessories , soldering iron with 7 accessories , soldring wire with 5 accessories
Tender For corrigendum : erection, testing, commissioning, trial operation & handing over including handling of materials at bhel / clients stores / storage yard and transportation to site, preparation of foundation, ndt, fixing of hangers & supports, application of lining, insulation, supply & painting, stenciling & labelling of steam turbine – generator – condenser with all auxiliaries, pumps (including cw, acw, raw water, misc.), dosing systems (lp, oxygen, naoh etc.), lube oil purification system, condenser on line tube cleaning system, plate heat exchangers, tg integral piping, dg sets and misc equipment etc., including tg-eots, fire detection & protection system of associated tg oil canal piping & mot room at unit-1 of 2x800 mw ntpc lara stpp stage-ii: package-a: unit # 1 - stg & auxiliaries along with all associated equipment, all misc. pumps (incl. cw, acw, raw water), piping, tg integral piping, dg sets, tg-eot, misc. equipment and fdps of tg oil canal & mot room of 2x800 mw ntpc lara stpp stage-ii
Tender For supply of details description of specification for 100 watt led flood light - led rating in warm)/system wattage/rated power, led luminaire conformity to 15:10322/part 5/section 5/2012 latest and 15: 16107, (part 2/sec 1):2012, photo biological safety of leds used shall be as per 15:16108/2012 (exempt grou, types of led luminave as per the 15: 161070part-2/sec-11/2012, types of led modules as per the 25: 16103(part 2)/2012, led rating/system wattage/rated power, luminaire system efficacy bumen/watt), ingress protection (ip rating) as per 1 10322 (part 1): 1982 latest, mounting brackets fincluded, warranty for free replacement (in year), input operating voltage range and frequency, automatic higher cut off voltage above 300 volt, rated voltage, ac power factor at hill load, driver efficiency lin sage), total harmonics distortion (in lage), the total circut power shall not be more than 110 percent of the valve declared, by the manufacturer, led chip efficacy, colour temperature (+500), working life for led (minimum 50,000 buming hours as per lm-80 report), coltur rendering index(cri), optic lenise materal (uv stabilued) (write na or without optic lense supply), heat sink should be die-cast aluminum along with sufficient heat sink fins to desipate heat effectively, capacitor shall be ratail for a temperature of 105 deg. ceblus or better, junction temperature, operating temperature range, operating humidity range, short circuit protection, overload protection, over voltage geutection, reverse polarity, high voltage test (1.5 kv for ane minute between napply terminats and body of the, unit), insulation resistance between earth and current carrying part, the luminaire shad be protected against surges and transients (internal), the luminaire shall be protected against surges and transients of >/1kv, (external, the luminaires casing/housing (single piece housing) shall be pressure de catted, aluminum alloy with higher thermal.conductivity, the lummaire body must be corrosion resistant epoxy powder couted, all fasteners must be of stainless steel, the entire housing (both led section and driver section) shall be dust and water proof having ip 66 protection as per 15:10322 (part 11:1987 latest, luminaries light transparency should be of toughened glass, toughened transparent glass cover thickness, toughened glass shall not get discolored shall not suffer degration due to heat and agning within warranty period, number of electronic control gest (power sanoles), driver components shall be industrial grade or above, pci shall be fre grade minimum 0.8 to 1.0 mm thick or mom, the luminaires works on single phase three wires system (phase, neutral and, earth, suitable connector shall be provided for led connection between driver output, and led, length of st marked three cors wire (shall be provided along with supply of, materiall, ught source, manufactures name and and brand on the aluminium die cast body, manufacturer's name, model number, serial number, date of manufactiare (month-year), and int number as identification mark inside each unit and the outside of each packaging box, the operation characteristics voltage and power be marked inside of each led, system must have emi/emc compliance as applicable (test reports shall be furnish on demand by buyer/consignee)