Web Analytics Made Easy - StatCounter

Integrated Power Supply Tenders

Get complete information related to latest Integrated Power Supply Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Integrated Power Supply Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Integrated Power Supply Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :45258862 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For consultancy work of civil work like rcc tri-mix road, asphalt road, paver block road, footpath, divider, traffic circle, street light, all type of building like community hall, party plot, complex, library building , gymnasium building, crematorium development, new garden development, beautification, solar power system, cctv camera, water supply, underground drainage, strom water drain, solid waste management etc. development related project work for various scheme.(second attempt)

CTN :45261704 Due date: 29 May, 202629 May, 2026 NA
Tender For supply of visitor management system vms software , f09 biometric device , u2000 12m uhf reader , uhf tag , c3-200 plus access controller , power supply , d-link cat6 lan cable grey , blank proximity rfid card thin , server room control system , computer system with keyboard webcam ups , installation charges

CTN :45256937 Due date: 27 May, 202627 May, 2026 3.23 Lacs
Tender For spares for “statcon” make modules for integrated power supply (ips) system of s and t system of chp of the katpp, rvunl, jhalawar

Central Government And Public Sector

CTN :45034478 Due date: 04 Jun, 202604 Jun, 2026 NA
Tender For tender for supply of radiation resistant cctv camera : : - type-ii (color ccd/cmos , 100m rad) radiation resistant camera head along with radiation resistant pan & tilt unit and mounting brackets. as per attached annexure-1 , corrigendum annexure-2 and annexure-3. , cabling system to transmit signals form vault cameras to ccu system which includes camera to ccu radiation resistant composite cable of 300 meters with 6 sets of cable connectors and applicable power cables as per annexure-1 , corrigendum annexure-2 and annexure-3. , field camera control unit and its racking system which includes 2 no. of camera control unit sub rack & 6 sets of camera control unit (ccu) cards (3 to be installed in field and 3 to be kept as spare for future ) as per annexure-1 , corrigendum annexure-2 and annexure-3 or equivalent sub rack system as per annexure-1 , corrigendum annexure-2 and annexure-3. , setup to convert ccu signals to optical signals which should include 3 no. of fiber optic transmitter and receiver set (capable of 4 camera system) and 6 no. of fiber patch cords , single mode , simpex and 3 no. of light interface unit 12 port , as per annexure-1 , corrigendum annexure-2 and annexure-3. , type-vi (color ccd/cmos sensor , non rr auto dome camera) with mounting brackets as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism to transmit signal from non radiation resistant camera including , poe power supply for non-rr ptz camera (6 no.) field jb /rack in ss material for non-rr ptz camera (2 no.) liu 6 port , din rail mountable for non radiation resistant ptz camera (3 no.) din rail 8 port un-managed network switches (3 no.). 4 no. of fiber patch cords , single mode , duplex for non-radiation resistant ptz camera or equivalent as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism for receiving signal at control room including light interface unit 24 port , rack mount (2 no.) and network video encoder (minimum 16-channel) along with accessories for intra-panel connections (2 no.) and 24 port un-managed network switches or equivalent (2 no.) , 4 no. of fiber patch cords , single mode , duplex as per annexure-1 , corrigendum annexure-2 and annexure-3. , recording and monitoring pc as per annexure-1 , corrigendum annexure-2 and annexure-3. , joystick suitable for mounting on control room panel cutout as per panel drawing as per annexure-1 , corrigendum annexure-2 and annexure-3. , 21 inch led backlit led color monitor as per annexure-1 , corrigendum annexure-2 and annexure-3. , video monitoring software setup as per annexure-1 , corrigendum annexure-2 and annexure-3 for minimum 9 camera. , mobile dolly consisting of camera control unit (ccu) , encoder , switch , joystick , engineering laptop with 15-inch to 17-inch screen , video management software for one camera , connection cables etc and their cabling as per annexure-1 , corrigendum annexure-2 and annexure-3. , control panel/rack 42u/ 27u setup for racking all instruments of cctv at control room as per annexure-1 , corrigendum annexure-2 and annexure-3. , cabling network optical fiber cable (6 core armored cable)-2000 meters twisted pair cable , rs485 , signal cable -200 meters unarmored coaxial cable rg59 -200 meters ethernet cable , cat-6 utp cable -610 meters video connector set -10 meters ethernet connectors rj-45 100 pieces conduit for cables 800 meters and other separate cables/ power cables/accessories required during installation one set of tool tackles for assembly/ disassembly/ of radiation resistant camera head viz. allen keys , lubricants , cable ties , loctite , heat sink , blank caps etc. 2 no. of control panel/rack size 27u setup for racking all instruments of cctv at field as per annexure-1 , corrigendum annexure-2 and annexure-3. as per annexure-1 , corrigendum annexure-2 and annexure-3 . , site installation & commissioning as per annexure-1 , corrigendum annexure-2 and annexure-3. , spare radiation resistance camera head s

Central Government / Public Sector

CTN :45255485 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For supply, installation and commissioning of pre-wired modular workstation consisting of a single control office customized to equip two sads and two daws systems arranged and installed on a t-shaped modular workstation with integrated cable management systems as per specifications. specifications of modular workstation: 1) the workstation shall each be of 5 feet (l) x5 feet (w) the combined size: 10 feet (l) x 5 feet (w) - 1set, made of 25 mm nfc wood and 1 mm acrylic laminate. 2) the sads displays shall be installed such that the bottom edge of the display is at a height of 5' (approximate) from the floor. these shall be installed preferably along the longer edge of the t and facing the operators, 3) the daws system shall be installed such that it is possible to be used sitting at the workstation. 4) all interconnecting wiring for lan, power supply and telephones shall be done inside the cable management system (powder coated aluminium interlocking extrusions) and adequate ports shall be provided on the work surface. communication accessories: i) lan rj45: 4 nos ii)telephone, rj11 : 4 nos iii) power supply, 5 amp sockets: 6 nos 5) all wires shall be brought out to interface boxes one for power supply and another for the communications cables. these boxes shall be designed to accept connections from the control room circuits. note: design, supply, fitment, installation, testing and commissioning shall have to done by the firm confirming to the pre-wired modular t- shaped workstation standards. material shall confirm to hpl/nfc engineered wood (25mm thickness) as per epd-ies-0012055:002 (s-p- 12055) certification. make: godrej interio/tumbi/greeken/moudulartek or its equivalent. [ warranty period: 30 months after the date of delivery ] ]

CTN :45168083 Due date: 25 May, 202625 May, 2026 NA
Tender For supply of smps based integrated power supply system (ips) as per block diagram enclosed as annexure as per rdso specification no. rdso/spn/165/2023 ver 3.0 with latest amendment details are enclosed]. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45240469 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For comprehensive annual maintenance contract for integrated power supply systems of m/s. statcon electronics make over mysuru division for 3 years (15 systems = non hmrdc section -14 systems & hmrdc section - 01 system).

CTN :45184535 Due date: 20 May, 202620 May, 2026 4.70 Lacs
Tender For dismantling & relaying the existing power/data/ telephonic cables in the new cable management system at epfo ro ambattur, chennai-37.

Central Government/Public Sector

CTN :45189259 Due date: 04 Jun, 202604 Jun, 2026 39.18 Lacs
Tender For design, supply, installation, testing and commissioning of power management system pms scada based on premise for all substations 6 nos at nit warangal campus

CTN :45195620 Due date: 25 May, 202625 May, 2026 NA
Tender For supply of procurement of dornier engine power management system training aid cum demonstrator
 Loading, Please wait...

Connect us via What's Up