Get complete information related to latest Interlocking Brick Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Interlocking Brick Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Interlocking Brick Tenders.
Tender For bhoj dharti,bhoj darara,bhoj mataur, group of 3 no. of habitations annual mtc.works for water supply - providing and laying of base course of floors, providing and laying of conglomerate floor, providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering, brick work with common burnt clay non-modular bricks of class. cement plaster on rough side of single or half brick wall.
Tender For bhoj dharti,bhoj darara,bhoj mataur, group of 3 no. of habitations annual mtc.works for water supply - demolishing dry brick pitching in floors, drains etc, providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering, steel reinforcement for r.c.c. work, brick work with common burnt clay modular bricks of class. cement plaster.
Tender For cement plaster (in fine sand) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) ,steel door/ window frames and shutters providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 1. using m.s. angels 40x40x6 mm for diagonal braces, sigle/built-up steel/tubular sections steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 1. in stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete,cement concrete (cast in situ) providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work below plinth level a,brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. cement mortar 1:4 (1 cement : 4 coarse sand)
Tender For providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work below plinth level and up to floor iv level: 3. 1:2:4 (1 cement : 2 coarse sand (zone-iii) : 4 graded stone aggregate 40 mm nominal size) ,brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor iv level in all shapes and sizes in : 1. cement mortar 1:4 (1 cement : 4 coarse sand),ement plaster
Tender For fixing bell mouths bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the engineer-in-charge. size of the main with which connection is to be made. 1. up to 200 mm internal diametre ,manhole chambers providing and fixing sfrc manhole covers and frames marked with is: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the engineer-in-charge. 1. type:- extra heavy duty set (ehd-35) 560mm clear opening, earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by engineer-in-charge. 1. all kinds of soil ,demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2. nominal concrete 1:2:4 or leaner mix (i/c equivalent design mix) cement concrete (cast in situ) providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work below plinth level and up to floor iv level: 6. 1:4:8 (1 cement : 4 coarse sand (zone-iii) : 8 graded stone aggregate 40 mm nominal size) .,steel reinforcement steel reinforcement for r.c.c. work, where not included in the complete rate of rcc, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level note: reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. thermo-mechanically treated bars of grade fe-500d or more,brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor iv level in all shapes and sizes in : 1. cement mortar 1:4 (1 cement : 4 coarse sand)
Tender For providing, lowering, laying, cutting (cut surface to be uniformly finished), jointing with rubber rings marked with is : 5382 and testing of spigot and socketted rcc, np2 marked with is : 458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete is all respects to the satisfaction to the engineer - in -charge. 4. 350 mm i/d ,`jointing plain and reinforced concrete pipes and specials of all classes in trenches using collar joints jointed with 1:1 cement sand mortar nearly dry heavily caulked into joints and with end dowels filled with 1:1 cement sand mortar including facing trowelling and finishing the joints at an angle of 45 degrees with faces of collars keeping joints wet till curved testing the drain lines for leakage and making good all leakage and defects as laid down in the contract specifications complete with two spigot ends jointed to collar and internal diameter of sewer pipe or special , earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by engineer-in-charge. 1. all kinds of soil ,cement concrete (cast in situ) providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work below plinth level and up to floor iv level: 3. 1:2:4 (1 cement : 2 coarse sand (zone-iii) : 4 graded stone aggregate 40 mm nominal size),brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 2. cement mortar 1:6 (1 cement : 6 coarse sand), cement plaster (in fine sand) 12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand)
Tender For brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. cement mortar 1:4 (1 cement : 4 coarse sand) ,lan and reinforced concrete pipes `jointing plain and reinforced concrete pipes and specials of all classes in trenches using collar joints jointed with 1:1 cement sand mortar nearly dry heavily caulked into joints and with end dowels filled with 1:1 cement sand mortar including facing trowelling and finishing the joints at an angle of 45 degrees with faces of collars keeping joints wet till curved testing the drain lines for leakage and making good all leakage and defects as laid down in the contract specifications complete with two spigot ends jointed to collar and internal diameter of sewer pipe or special being. ` 7. 350 mm internal diametre sewer pipe
Tender For brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. cement mortar 1:4 (1 cement : 4 coarse sand) ,lan and reinforced concrete pipes `jointing plain and reinforced concrete pipes and specials of all classes in trenches using collar joints jointed with 1:1 cement sand mortar nearly dry heavily caulked into joints and with end dowels filled with 1:1 cement sand mortar including facing trowelling and finishing the joints at an angle of 45 degrees with faces of collars keeping joints wet till curved testing the drain lines for leakage and making good all leakage and defects as laid down in the contract specifications complete with two spigot ends jointed to collar and internal diameter of sewer pipe or special being. ` 7. 350 mm internal diametre sewer pipe
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking
Tender For supply of modernization of distribution infra 2x400 kva substation companybagh b b -dismantling and refurbishing of electrical distribution system , itc of existing load bank with static meter , itc of existing load bank , trimming and pruning of four trees , transportation of one dismantled lt panel darbhanga to mzp , removing of old faulty outlived mv panel , provision of structural iron channels mounting framework for the lt panel , re-furbishment of existing mv panel , brickwork for minor structural alterations near the lt panel support base , straight through joint 185 , straight through joint 50 , removing and relaying of existing cement interlockingbricks , laying of 1.1 kv grade of 35 sqmm to 185 sqmm direct in ground , dressing of cables , finishing of the lt bus bar box , 20w surface-mounted led tube light , a. horizontal type tpn db 8 way with double door , b. horizontal type tpn db 8 way single door , a. vertical type, 415 v, tpn db 8 way double door , dressing of dbs , a. single pole mcb 6 to 32 a , b. four pole isolator 63 a , c. four pole isolator 40 a , d. double pole isolator 40 a , e. tp mcb 63 a , f. 125 a tp mccb 16 ka , 3 pole mccb of 250a, 25 ka , itc of existing lt bus bar box , sitc wall mounted heavy-duty air circulators fans of 600mm metal blades , supplying and fixing of 5mm thick m.s.chequered plates , fixing of ms stand of pac outdoor unit , providing double coat spray painting , sign writting numbering on all panel proper marking of its connectivity , a. wiring for light point group-a , a. copper conductor, single core cable 2 x 1.5 sq. mm , a. medium class pvc conduit 20 mm , shifting re- installation of submersible pump staters , making opening of wall to suit the size of 380 mm sweep exhaust fan , supplying fixing of exhaust fan of 380 mm sweep heavy duty , a. blanking plate , b. 5 pin 15 a socket , c. 15 16 a piano type switch , d. 5 6 a piano type switch , e. 3 pin 5 6 a socket outlet , f. 3 pin 15 a top , g. wall fan , h. down rod for ceiling fan installation 3 ft length hook , a. 100 watt flood light , b. 24 w led rimless surface panel light , sitc of 100 a 3 phase neutral copper bus bar in sheet steel enclosure , dressing of existing distribution system of type ii staff qtr , itc of 100 a 3 phase neutral bus bar with 100 a mccb in sheet steel enclosure , supplying fixing of double pole spn mcb 32 a in the sheet steel enclosure , s l 2 1.5 sqmm copper conductor , removing the faulty lt cable of size 3.5 core 240 sq.mm , ms clamp on four pole structure for fixing the ht cable , extracting of spare main ht cable 11 kv 95 sq mm size from the soil , extracting of faulty spare ht cable 95 sq mm from the duct manual labour , fastners nut bolt, al lugs, socket, cu lugs socket, washers, screw, pvc clips , acrylic sheet of 2 mm thickness , hrc fuse of 200 a //bid details 2 / 49