Tender For corrigendum : supply of distributing bar (make: fresenius) , blood pump control (make: fresenius) , light barrier for heparin pump (make: fresenius)
Tender For procurement of medical consumables items for use by the department of cardiovascular and thoracic surgery, goa medical college - adult membrane oxygenator with hard shell reservoir 1. should have heparin free, hydrophilic polymer surface balance coating. 2. should have open circuit configuration 3. should have hard shell venous reservoir of capacity more than 4000ml. with built of cardiotomy reservoir with 30m filter capacity.4. should have blood flow range 0.5 ltr to 7 ltr/min.5. should have priming volume less than 200ml6. should have high efficiency heat exchanger positioned in post pump configuration.7. venous return port 1/2" with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8" venous inlet 1/2" membrane surface area 1.8 to 2.5m210. should have sampling port.11. us fda and ce approval is required., adult membrane oxygenator with hard shell reservoir with integrated arterial filter 1. should have heparin free, hydrophilic polymer surface balance coating. 2. should have open circuit configuration 3. should have hard shell venous reservoir of capacity more than 4000ml. with built of cardiotomy reservoir with 30m filter capacity.4. should have blood flow range 0.5 ltr to 7 ltr/min.5. should have priming volume less than 200ml6. should have high efficiency heat exchanger positioned in post pump configuration.7. venous return port 1/2" with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8" venous inlet 1/2" membrane surface area 1.8 to 2.5m210. should have sampling port.11. us fda and ce approval is required., small adult membrane oxygenator with hard shell reservoir 1. should have a micro porous hollow fiber membrane oxygenator 2. should have open circuit configuration 3. should have hard shell venous reservoir of capacity more than 3500ml. with built of cardiotomy reservoir with 30m filter capacity.4. should have blood flow range 0.5 ltr to 4 ltr/min.5. should have priming volume less than 200ml6. should have high efficiency heat exchanger positioned in post pump configuration.7. venous return port 1/2" with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8" venous inlet 3/8" 10. should have sampling port.11. us fda and ce approval is required., small adult membrane oxygenator with hard shell reservoir with integrated arterial filter 1. should have a micro porous hollow fiber membrane oxygenator with integrated arterial filter2. should have open circuit configuration 3. should have hard shell venous reservoir of capacity more than 3500ml. with built of cardiotomy reservoir with 30m filter capacity.4. should have blood flow range 0.5 ltr to 4 ltr/min.5. should have priming volume less than 200ml6. should have high efficiency heat exchanger positioned in post pump configuration.7. venous return port 1/2" with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8" venous inlet 3/8" 10. should have sampling port.11. us fda and ce approval is required., paediatric membrane oxygenator with hard shell reservoir 1. should have a micro porous hollow fiber membrane oxygenator 2. should have open circuit configuration 3. should have hard shell venous reservoir of capacity more than 3500ml. with built of cardiotomy reservoir with 30m filter capacity.4. should have blood flow range 0.5 ltr to 3.5ltr/min.5. should have priming volume less than 140ml6. should have high efficiency heat exchanger position in post pump configuration.7. venous return port 3/8" with rotating facility and reducers8. should have an auto vent facility.9. pot size : arterial outlet, venous outlet 3/8" venous inlet 3/8" with reducers10. us fda and ce approval is required., paediatric membrane oxygenator with hard shell reservoir with integrated arterial filter 1. should have a micro porous hollow fiber membrane oxygenator with integrated arterial filt