Get complete information related to latest Ionizer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ionizer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ionizer Tenders.
Tender For corrigendum : supply of brake valve part number tb66043 , propeller shaft rear part number td66135 , valve , pilot part number ya00054329 , filter part number 2655742461 , plug, drain part number 263g750061 , injector, doser part number te68615 , lube oil filter part number te66283 , crankcase breather filter element part number te66716 , fuel filter spin on type ff91217 part number te18980 , fuel water separator cartridge part number te16975 , strainer part number td66503 , air filter, primary part number td66470 , element,filter part number ya00033065 , element part number 4251527 , filter part number ya00001490 , air filter,safety part number td66471 , filter trans part number 0501333764 , breather air part number 2631543371 , bolt part number 5643051061 , washer part number 5660051471 , breather air part number 1632302242 , breather air part number 263g782251 , breather part number td08056 , alternator part number tb70500346 , motor, starting part number tb70500357 , tensioner, belt part number tb70500173 , pulley, idler part number tb70500176 , after-treatment system part number tb66071 ) /bid number : gem/2026/b/7477379 * /dated: 20-05-2026 & & / bid document 1 / 32
Tender For corrigendum : procurement of bias damper spares for ntpc lara - seal&o-ring kit,01.00/ 4s069933-000,pspl, element,03.04.01/4s033718-0+,pspl, fitting set,02.00/ 4s069933-000,pspl, air breather,01.05/4s033718-000,pspl, suction strainer,02.04/4s033718-000,pspl, sol coil,03.03.01/4s033718-0+,pspl, pump coupling,09/3s030062-000/4s+,pspl, motor coupling,03/3s030062-000/4s+,pspl, seal&o-ring kit,01.00/ 4s069932-000,pspl, element,03.04.01/4s033717-0+,pspl, fitting set,02.00/ 4s069932-000,pspl, air breather,01.05/4s033717-000,pspl, suction strainer,02.04/4s033717-000,pspl, sol coil,03.03.01/4s033717-0+,pspl, pump coupling,09/3s030062-000/4s+,pspl, motor coupling,03/3s030062-000/4s+,pspl, direct actng prv,03.01/4s033718-000,pspl, pressure switch,03.054s033718000,pspl, cntrl manifold assy,03.104s033718+,pspl, hyd cylinder,3s034390-000,polyhydron,, seal kit,sk80kn10056400,pspl, seal kit,sk40kn8045300,pspl, gear pump(fd),02.03/4s033718-000,pspl, gear pump(fd),02.03/4s033717-000,pspl
Tender For invitation quotation for data rates of electrical items. - releasing and refixing of 30 mtr polygon highmast pole includes mechanical accessories and lighting arrestor,labour charges, hiring of crane and transportation charges. (excluding foundation work), releasing and refixing of 12/16/20 mtr polygon highmast pole includes mechanical accessories and lighting arrestor,labour charges, hiring of crane and transportation charges. (excluding foundation work), releasing and refixing of tubular/ octagonal/conical poles of height 5 mtr to 10 mtr height. including labour, crane and transportation charges. (excluding foundation work), amc chagres for 180 to 200 kva dg set including a. draining of lubricating oil sump, clean sump, strainer, and filter gauge. b. renewal of lubricating oil filter element. c. refilling the sump with new oil and prime the lubricating oil system.d. check and adjust fan belt tension. e. checking and adjustment of tappet clearance. f. checking and tightening engine breather cap screws. and all materials included, amc chagres for 125 to 160 kva dg set including a. draining of lubricating oil sump, clean sump, strainer, and filter gauge. b. renewal of lubricating oil filter element. c. refilling the sump with new oil and prime the lubricating oil system.d. check and adjust fan belt tension. e. checking and adjustment of tappet clearance. f. checking and tightening engine breather cap screws. and all materials inclueded, amc chagres for 63 to 100 kva dg set including a. draining of lubricating oil sump, clean sump, strainer, and filter gauge. b. renewal of lubricating oil filter element. c. refilling the sump with new oil and prime the lubricating oil system.d. check and adjust fan belt tension. e. checking and adjustment of tappet clearance. and other all material included, hire charges for servicing & maintaining of 3 ton cassette type air conditioner includes fillling of gas, checking of electrical wiring connection for tightness. straighten up to normal position coil fins using comp. inspect compressor motors for proper operation. lubricate shafts bearing and motors.inspect fan for bent blade and correct as necessary, hire charges for servicing maintaining of 2 ton split type air conditioner includes fillling of gas, checking of electrical wiring connection for tightness. straighten up to normal position coil fins using comp. inspect compressor motors for proper operation. lubricate shafts bearing and motors. inspect fan for bent blade and correct as necessary, servicing & maintaining of 10 kva ups system with battery for the period of 1 year includes (i) inspection, diagnosis, component replacement, testing and validation of functional ups units., servicing & maintaining of 5 kva ups system with battery for the period of 1 year includes (i) inspection, diagnosis, component replacement, testing and validation of functional ups units., servicing & maintaining of 3 kva ups system with battery for the period of 1 year includes (i) inspection, diagnosis, component replacement, testing and validation of functional ups units, remote control and monitoring of individual streetlight using lora communication technology a lora-based street lighting system utilizes lora (long range) communication technology to create a low-power, wide-area network (lpwan) for the remote control and monitoring of streetlights. each streetlight node is equipped with a microcontroller, a lora transceiver, and sensors such as ldrs or pir for ambient light detection and motion sensing., supply and installation of electronic timer for streetlights consisting of microcontroller based electronic timer with rtc, 2x16 lcd wit back light, 5 tactile keys, supplying and installation of intelligent three phase centralised control and monitoring system for street lights, the ccms unit should be capable of switching on & off the lights of a particular switching or networked switching points from central control system automatically