Tender For tender for supply of dual chamber aicd complete with accessories (mri compatible) , trans catheter dual chamber leadless pacing system av , permanent pacemaker vvir complete set with lifetime warranty (mri compatible) , combo device complete with acessories , 3 t full body scan conditional his bundle pacing system for brady arrhythmia , implantable loop recorder(insertable) with minimum battery life of 3 years , with proven accuracy of 99percent , with globally connected remote monitoring facility , single chamber aicd vrt-dx-icd mr conditional with complete atrial diagnostic plus hf monitoring plus av optimisation , ivus catheter compatible with 5f guide , coronary microcatheter , intra coronary guide extension catheter/support catheter (us fda approved) , coronary orbital atherectomy cathetr , temporary bipolar pacing lead (usfda/ce/bis approved) , act test cartridges , oct catheter , guide wires radiofocus st tip 0.035inch x 150 cms , inoue percutaneous transvenous mitral commissurotomy balloon complete with accessories - assorted sizes , c arm covers , ultrasound probe cover , suture mediated vascular closure device 6f for (5f-24f) , readymade gauze pieces 36 tpi , 10 x 10 cm x 12 ply , starch & chlorine free with radiopaque line in autoclavable double packing with indicator pack of 6 , gauze surgical , open wove , unmedicated 60 cm wide x 18 mtr (packet) , pad abdominal swab 40 x 25 cm with tape , 30 cm , coronary guidewire sion tec technology , actone braiding , 1.5cm silicone coating , 40 cm hydrophilic coating , 8.5cm spring coil length , tip diameter 0.014 inch , tip load 0.5 gm , , coronary guidewire tip load 0.8 gm , hydrophilic coating with polymer sleeve 20cm , tip radiopacity 3 cm , disposable standard back table cover drape for cath , thin triple layered self adherent bordered soft silicon dressing with safetac layer thin flexible non woven layer of viscose and poluyester and backing polyureathane film size 5 x 12.5cm , disposable pacemaker drape (us fda certified) , judkins right angiography catherer - assorted sizes , judkins left angiography catherer - assorted sizes , sterile powder free micro optic gloves with composition of epoxy brown a.r.t.gamma sterile aql 0.065 size 6.5 , sterile powder free micro optic gloves with composition of epoxy brown a.r.t gamma sterile aql 0.065 & avo.p size 7.0 , sirolimus based nano carrier drug eluting coronary balloon catherter diameter (1.5 mm-4.00 mm) & length (10mm- 40 mm) , balloon therapeutical in stent restenosis and denovo lesion paclitaxel lux coating technology balloon , radial diagnostic angiographic catheter 5f/6f , deflectable decapolar electrophysiology catheter with connector 6f , 4mm push pull handle , fixed curved quadripolar electrophysiology catheter (6f , 4mm) crd-2 5mm electrode spacing , with compatible connector , bidirectional irrigated ablation catheter with 12 port with connector , cool point tubing set for irrigated rf catheter st jude , duo decapolar electrophysiology catheter 20 poles 7f with compatible connector , brk needle adult , mullin sheath different sizes , deflectable radiofrequency ablation catheter (7f , 4mm) 2-5-2 electrode spacing-all curved with compatible connector
Tender For procurement of medical stores - everolimus eluting drug coated cobalt chromium coronary stent system non erodible polymer, assorted sizes ( length upto 48mm), biodegradable polymer coated cobalt chromium sirolimus drug eluting stent system with laser cut seamless tubing in serpentine pattern with 60 micron strut thickness, guide wires radiofocus angle tip 0.035" x 150 cm, percutaneous catheter introducer sheath set 11cm 6f size (assorted size), ptca guide catherer - speciality curves - assorted shapes and sizes, pmda approved radial artery hemostasis device (tr band) consists of two balloons specially designed for spot compression of the radial puncture site
Tender For tender for supply of everolimus coated drug eluting platinum chromium coronary stents assorted sizes , everolimus eluting cobalt chromium stents with thin strut thickness 0.0032 and fluorinated copolymer with multi link 8 multilayer pebax balloon mounted and mid marker for stent placement with a rbp of 18atm assorted sizes till maximum of 38mm length , everolimus drug eluting cobalt cromium stent with thinstrut thickness 0.0032 which is 4th generation coated with biocompatible fluorinated copolymer multi link 8 peak to valley 3 3 3 tailler and nonlinear link assorted sizes including 48mm lengths , zotarolimus drug eluting coronory stent system with core wire technology platinium iridium core and continous cobalt chromium sinusoid technology assorted sizes , sirolimus eluting bioresorbable vascular scaffold bvs of plla backbone bioresobable polymer pdlla strut thickness of 100 micron hybrid cell design with triaxial ro markers. assorted sizes , sirolimus eluting coronary side branch stent system with 65um 0.065mm or 0.0026 strut thickness l605 cobalt chromium alloy and biodegradable plla plus plga polymer. assorted sizes , sirolimus eluting coronary tapered stent system with hybrid cell design 65um 0.065mm or 0.002 strut thickness l605 cobalt chromium alloy and biodegradable plla plus plga polymer. assorted sizes , sirolimus eluting cobalt chromium coronary stent system with ultra thin struts 60microns across all diameters and length with a biodegradable polymer. open cell design with long dual z connectors. assorted sizes , everolimus eluting cobalt chromium coronary stent system with ultra thin struts 60microns across all diameters and length with a biodegradable polymer. open cell design with long dual z connectors. assorted sizes , sirolimus drug coated balloon with nanolute techonology low entery profile tip of 0.016 . assorted sizes , drug eluting coronory balloon with urea paclitaxal coating assorted sizes , dual drug polymer free everolimus and probucol eluting coronary stents system with abluminal coating microporous surface and shellac resin top coat having 0.89mm crossing profile and optimal strut thickness assorted sizes , covered coronary stent for use in life threatening coronary perforations or ruptures as bail out strategy assorted sizes , carotid stent system with closed cell design assorted sizes , sirolimus drug eluting cobalt chromium stent with ultrathin strut thickness 60 um des coated with amorphous silicon carbide biodegradable polymer and gradient albuminal coating hybrid open cell and double helix assorted sizes. , sirolimus eluting cobalt chromium coronary stent with advance core wire shaft technology and bioresorble albuminal gradient coating assorted sizes , sirolimus eluting cobalt chromium coronary stent with shorter strut and bands flexible multi joints in phase 2 link open cell design and bioabsorble albuminal coating gradient. assorted sizes , sirolimus eluting cobalt chromium coronary stent with bioresorble albuminal gradient coating assorted sizes , 3t whole body safe mri dual chamber pacemaker with deflectable his bundle pacing catheter his bundle pacemaker with mapping capabilities , antimirobial iodine impregnated incison site sterile plastic sheet
Tender For tender for supply of drugs and pharmaceuticals - human insulin analogue long acting basal inj 100 iu ml recombinant dna origin 300 iu disposable pen with 5 needles per pen , gliclazide mr 30 mg tab , glipizide 5mg tab , sitagliptin 50 mg metformin 1000 mg tab , insulin lispro biphasic injection i dot p 25 insulin lispro and 75 insulin lispro protamine suspension , sirolimus 1mg tab , pioglitazone hydrochloride 15mg tab , alendronate sodium 70mg tab , neostigmine 0 dot 5mg 1ml inj , cisatracurium 2 mg ml inj 10ml vial , tacrolimus 1mg prolonged release cap , mycophenolate mofetil 750mg tab , intravenous immunoglobulin ivig 10gm bott of 50ml , calcium phosphate 0 dot 24 mg 5 ml syp , calcium acetate 500 mg tab , carnitine 200 mg tab , acyclovir ophth ointment 3 w w in 5 gm tube , ciprofloxacin hcl 0 dot 3 tube of 5 gm , ciprofloxacin hcl 0 dot 3 dexamethasone 0 dot 1 bott of 5ml , cyclosporine eye drop 0 dot 05 bott of 3 ml , fluorescein sodium 20 3 ml inj , flurbiprofen sodium ophthalmic soln 0 dot 03 vial of 5 ml , homatropine hydrochloride soln 2 , ketorolac tromethamine 0 dot 4 eye drops , natamycin 3 eye drops in 3 ml bott , carboxy methyl cellulose cmc 1 gel , ofloxacin 0 dot 3 bott of 5 ml , pilocarpine nitrate eye solution 2 bott of 5 ml , pilocarpine intracameral inj 0 dot 5 pilocarpine nitrate intra ocular inj without preservatives amp of 01ml each , prednisolone acetate 1 w v bott of 5 ml , sodium chloride 6 w w ointment tube of 3 gm , azelaic acid 20 cream tube of 15 gm , cream luliconazole tube of 15 gm , tobramycin 0 dot 3 bott of 5 ml , tropicamide 1 with 5 phenylephrine eye drops bott of 5 ml , tropicamide eye solution 1 bott of 5 ml , trypan blue 0 dot 6 inj in vial of 1ml , amphotericin b 0 dot 5 eye drops bott of 5 ml , atropine sulphate 1 w v eye drop bott of 3 ml , atropine sulphate oint 1 tube of 3gm , olopatadine hydrochloride 0 dot 1 ophthalmic soln bott of 5ml , olopatadine 0 dot 2 ophthalmic soln bott of 5 ml , proparacaine eye drops 0 dot 5 bott of 5 ml , moxifloxacin hcl 0 dot 5 & dexamethasone 0 dot 1 ophthalmic soln bott of 5ml , diphenhydramine 10 15 mg per 5 ml and ammonium chloride 100 150 mg sodium citrate 50 85 mg per 5ml syp bott of 100ml , beclomethasone dipropionate nasal spray 50 mcg per dose metered dose 150 units , betahistine dihydrochloride 16mg tab , clotrimazole 1 w v ip lignocaine 2 w v ip ear drop bott of 10ml , chloramphenicol 5 w v clotrimazole 1 w v betamethasone 0 dot 25 w v lignocaine hcl 2 w v in bott of 5 ml , xylometazoline hcl 0 dot 05 w v nasal solution for paed use bott of 10ml
Tender For supply of srphc153055-coronary drug eluting stents with (1) stent on stainless steel or cobalt chromium alloy or platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus everolimus paclitaxel or zotarolimus shown to be effective in preventing neo- intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm and length of the stent from 12mm to 38 mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system shou ld be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell or hybrid cell type (8) stent should be a pproved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) the long term efficacy for ten years and safety of the stent in terms of target vessel revascularisation (tvr) a nd in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals.( 10) the documents pertaining to the efficacy and safety of the stent should be enclosed for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of sup ply of the stent to a major government institute. unit:no [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 la cs ]
Tender For srphc153042-coronary drug eluting stents with (1) stent on cobalt chromium alloy o r platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus e verolimus or zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent di ameter should be from 2.5mm to 4mm and length of the stent should be 12mm to 48mm. (4) the str ut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single ope rator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) s tent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi appro val should be enclosed in the tender bid. (9) the long term efficacy and safety of the stent in ter ms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / p ublished in peer reviewed scientific journals. (10) the documents related to the efficacy and safe ty of the stent should be only for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institut e. unit:no ]
Tender For srphc153041-coronary drug eluting stents with (1) stent on cobalt chromium alloy o r platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus e verolimus or zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent di ameter should be from 2.5mm to 4mm and length of the stent from 12mm to 38 mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single opera tor exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) ste nt design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approva l should be enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / publi shed in peer reviewed scientific journals.(10) the documents pertaining to the efficacy and safety of the stent should be enclosed for the brand that is offered in the tender bid (11) the manufact urer/supplier should submit proof of supply of the stent to a major government institute. unit:no ]