Get complete information related to latest Iron Pole Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Iron Pole Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Iron Pole Repair Tenders.
Tender For supply of supply of hot dip galvanized octagonal street light pole of 7 mtrs length , supply of outdoor type 100w led type flood light luminaire , supply of outdoor type 90w led streetlight luminaire , design, fabrication, supply, installation, testing and commissioning of cubicle type, outdoor type feeder pillar panel , sitc of lt feeder pillar panel , supply power cable of 3. 5 x 50 sq. mm sqmm. , supply of xlpe insulated and pvc sheathed armoured aluminium conductor ug power cable of 4 x 16 sqmm. , supply of xlpe insulated and pvc sheathed armoured aluminium conductor ug power cable of 3. 5 x 300 sqmm. , supply of 50 mm od hdpe pipe of pe 80 pn 6 isi marked , supply of 63 mm od hdpe pipe of pe 80 pn 6 , supply of 110 mm od hdpe pipe of pe 80 pn 6 , supply of underground warning or caution tape size 6 x 250 mtr , supplying and making end termination 3. 5 x 50 sq. mm , supplying and making end termination 4 x 16 sq. mm , supplying and making end termination 3. 5 x 300 sq. mm , excavation for cable trenches in soft soil , laying of upto 63 mm dia size dwc or hdpe pipe , laying of 110 mm dia size dwc or hdpe pipe , laying of cable up to 35 sq. mm in the existing rccor hume or duct or metal or dwc or hdpe pipe as required. , laying of cable above 35 sq. mm and upto 95 sq. mm in the existing rccor hume or duct or metal or dwc or hdpe pipe as required. , laying of cable above 185 sq. mm and upto 400 sq. mm in the existing rccor hume or duct or metal or dwc or hdpe pipe as required. , laying and fixing of cable above 185 sq. mm and upto 400 sq. mm on wall surface , supplying and making of straight through joint with heat shrinkable kit 3. 5 x 300 sq. mm , dismantling bituminous road by manually or mechanical , supply and fixing of single arm bracket having arm length of 1. 2 mtr , supply and fixing of double arm bracket having arm length of 1. 2 mtr , supply of dp mcb, 6 a, c curve , supplying 3 core 1. 5 sqmm of frls pvc round sheathed copper conductor industrial cable , erection of metallic pole upto 7 mtr length including rcc foundation , installation, testing, and commissioning of 90w led type street light fixture , installation, testing, and commissioning of 100w led type flood light fixture , earthing with g. i. earth pipe 4. 5 meter long, 40 mm dia including accessories , providing and fixing 6 swg dia g. i. wire , providing and fixing 25 mm x 5 mm g. i. strip in 40 mm dia g. i. pipe , providing and laying in position cement concrete , dismantling of existing street light poles up to 9 meters , supply and erection of extra supporting ms structure with l channel , laying of caution tape over the cable trench
Tender For nit 356 supply of electrical line materials under oandm head for f.y. 2025-26 under esa, giridih. - electrical items :, ms nuts & bolts 3" (f.th.) (galvanized), ms nuts & bolts 4" (f.th.) (galvanized), ms nuts & bolts 8" (f.th.) (galvanized), ms nuts & bolts 10" (f.th.) (galvanized), pg clamp for 200 sq. mm conductor, pg clamp for 150 sq. mm conductor, pg clamp for 100 sq. mm conductor, pg clamp for 80 sq. mm conductor, angle/side stay clamp (50*6 mm)for 8 mtr 200kg psc pole [galvanized], earth clamp for earthwire (50*6 mm) [galvanized] [1.8 kg.], packing piece for rail pole [ 3.7 kg. per pair ], 33 kv pole top bracket for 60 kg. rail pole [galvanized] [ 3.58 kg. per no.], back clamp (50*8 mm] for 33 kv "v" cross arm & top bracket for 9 mtr 400 kg. psc pole [galvanized] [3 kg.], 33 kv stay clamp side/angle (50*6 mm) for 60kg. rail pole [galvanized] [ 1.92 kg. ], 33 kv cross bracing [50*50*6 mm] for dp channel [galvanized] [ 64.3 kg. ], 33 kv clamp for cross bracing set of 2 pair for 60 kg. rail pole [galvanized] [1.872 kg. each ], 11 kv clamp for cross bracing set of 2 pair for 9 mtr 400kg. psc pole [ 1.3 kg. ], 11 kv side stay clamp (50*6 mm) for 8 mtr. 200kg. psc pole [ galvanized ] [1.08 kg. ], dp channel support clamp (50*6 mm) for 8 mtr. 200kg. psc pole [galvanized] [1.1 kg. each ], 33 kv dp channel support clamp (50*6) [1 pair= 1 set ] for 9 mtr. 400kg. psc pole [galvanized] [1.5 kg. each ], 11 kv pole top bracket [50*8] [galvanized] [2.2 kg. per no.], 11 kv back clamp [50*6 mm] for top bracket [galvanized] [1.3 kg. per no.], 11 kv back clamp [50*6 mm] for "v" cross arm for 9 mtr. 400kg. psc pole [galvanized] [3 kg. ], 11 kv angle stay clamp [50*6 mm] for 8 mtr 200kg. psc pole [galvanized] [1.08 kg. ], 11 kv back clamp [40*6 mm] for line d.p channel [galvanized] [1.92 kg.], clamp (50*6 mm) for transformer base channel [galvanized] [3.2 kg. ], clamp (50*6 mm) for transformer belting [galvanized] [1.872 kg. ], clamp (50*6 mm) for lt bus & h.g fuse set [galvanized] [1.872 kg. ], clamp (50*6 mm) for ab switch base channel for 60kg. rail pole [galvanized] [2.4 kg. ]
Tender For bid to ras corrigendum : supply of laying of volleyball court synthetic surface poles and allied accessories :-- hard standing platform first sand layer quary rock layer , synthetic surface asphalt concrete base bitumen , non playing area area excluding playing area and technical area , led flood lights 100 watts each with 8 meter long ironpoles , volleyball net alongwith antenna of 01 meter length and 10 meter width and two plastic antenna poles , ironpole for volleybal net with 2. 43 meters height , chain link fence 7 feet high al round the court with dimensions , digital score board mentioning teams playing score of respective teams, numbers od sets played with score , scorers table iron material with 02 capacity , referee chair galvanized steel referee chair of 2. 4meters height 0. 8 meters width , staircase seating for audience two steps of concrete with length of 9 meter width of 90 centimeter , storm water drain to avoid stagnation of water of width 60 and depth 60 to be constructed along the court , pathway of 5 meter and 1 meter of concrete with anti skid checkered tiles , stage shade of iron will be constructed between the staircase seating with 4. 5 meters and 3. 4 meters
Tender For tender for supply of solar motion based sensor led wildlife lights -pole 6 m height hot dip galvanized suitable for outdoor wildlife installation , solar module 110 w mono crystalline high efficiency outdoor grade , battery lithium type 12 point 8 v 42 ah maintenance free , led light 30 watt actual load pole mounted high efficiency , motion sensor with dusk to dawn control including clamps nuts bolts and hardware
Tender For corrigendum : 318/supply of electric line materials - electrical items :, 33 kv v cross arm ( 9 mtr, 400kg psc pole) (100x50x6mm) [galvanized], back clamp for v cross arm ( 9 mtr, 400kg psc pole) ( 50x6mm) [galvanized], pole top bracket (400kg psc pole)(100x50x6mm) [galvanized], back clamp pole top bracket (400kg psc pole) ( 50x6mm) [galvanized], 11kv v cross arm ( 8 mtr, 200kg psc pole) (75x40x6mm) [galvanized] [galvanized], back clamp for v cross arm (200 kg psc pole) ( 50x6mm) [galvanized], pole top bracket ( 8 mtr, 200kg psc pole) (75x40x6mm) [galvanized], back clamp for pole top bracket (200 kg psc pole)( 50x6mm) [galvanized], 11 kv hg fuse set channel (75x40x6mm) [galvanized], support clamp for hg fuse set channel[galvanized], transformer base channel( 100x50x6 mm) 2800 mm long )[galvanized], support clamp for transformer base channel(50x6mm) [galvanized], 11 kv top channel ( 100x50x6 mm) (3200 mm long) [galvanized], support clamp for top channel(50x6mm) [galvanized], 11 kv line dp channel (75 x40x6mm) 2800 mm long) [galvanized], support clamp for 11 kv line dp channel[galvanized], 33 kv line dp channel (100mm x 50mm x 6mm) 3150 mm long) [galvanized], support clamp for 33 kv line dp channelfor 400 kg psc pole [galvanized], 11 kv cross bracing for d p structure (50x50x6mm) [galvanized], clamp for11 kv cross bracing[galvanized], 33 kv cross bracing d p structure (50x50x6 mm) [galvanized], clamp for 33 kv cross bracing[galvanized], lt angle bus bar with clamp(50x50x6mm) [galvanized], d.p channel support clamp (50x6 mm) for 8 mtr 200kg psc pole [galvanized]
Tender For corrigendum : 314/supply of electric line materials - electrical items :, gi wire no. 6, gi wire no. 8, gi wire no. 10, 11 kv stay set complete (1800x16 mm) with stay wire 7/10 swg and guy insulator, earthing (chemical) with gi earthing pipe 20 mm 2.5 mtrs. long, earth clamp for earthwire (50 x 6 mm)[galvanized] (1.8 kgs.), gi stay set complete for d/s/s (1900x 16mm) with staywire 7/12 swg and guy insulator, gi service pipe 40 mm diameter 3 mtr length, lt stay set complete (1700x16 mm) with stay wire 7/12 swg, angle/side stay clamp ( 50x6 mm) for 8 mtr 200kg psc pole[galvanized] (1.08 kgs.), galvanized nuts and bolts , 2.5 inch (full thread) 5/8 inch dia, galvanized nuts and bolts, 3 inch (full thread) 5/8 inch dia, galvanized nuts and bolts, 4 inch (full thread) 5/8 inch dia, galvanized nuts and bolts, 7inch (half thread) 5/8 inch dia, galvanized nuts and bolts, 8 inch (half thread) 5/8 inch dia, galvanized nuts and bolts, 10 inch (half thread) 5/8 inch dia, galvanized nuts and bolts, 12 inch (half thread) 5/8 inch dia, gi stay set complete for d/s/s (1900x 20mm) with staywire 7/10 swg and guy insulator, stone base plate for 11 kv, dss, lt, gi base plate for 33kv (500x500x10 mm) avg weight 19.6kg/plate, earthing (chemical) with gi earthing pipe 40 mm 3.1 mtrs. long (bentonite as intermittent layers), earthingg.i.strip (65x6)mm2, danger board 33 kv/ 11 kv/ lt, anticlimbing device(barbed wire) 2x12 swg, aluminium winding wire/tape/strips etc..
Tender For supply of mcb - miniature circuit - breakers for a. c. operation as per is / iec 60898 (part 1) (q2) , led luminaire for road and street lights (v2) conforming to is 10322 (part 5 / section 3) (q3) , piano type non modular electrical switch socket combination as per is 3854 and is 1293 (q3) , piano type modular domestic fan regulator as per is 11037 (q3) , aluminium ferrules 95sqmm , aluminium ferrules 70sqmm , aluminium ferrules 50sqmm , aluminium ferrules 35sqmm , aluminium ferrules 25sqmm , aluminium ferrules 16sqmm , aluminium ferrules 10sqmm , aluminium ferrules 6sqmm , brass screw 1 2 inch , brass screw 1 inch , brass screw 3 4 inch , fan capacitor 1piont 5 mfd , mcb tpn 100amps , led solar street light fitting 60watt incl galvanized steel pole complete
Tender For 25 kv earthing/discharge rod assembly for high rise ohe with working voltage 25 kv ac traction with top clamp (suitable for 36 to 50 mm bus bar and also suitable for 10 to 20 mm dia. conductor) . pole made of cast resin or resin-bonded glass fibre, coated with three coats of poly- urethane, the discharge /earthing pole assembly shall have an overall length of not less than 7.5 meters in five equal sections. single core flexible multi strand annealed copper cable should have double insulation, a cross section of 40 sq mm of size 248/0.45 mm and 14 meter long cable (specification is: 1554 (pt. i)- 1988 and is 2071 (pt. 1 and iii). with earthing double clamp drg. no. eti/ohe/sk/482 or latest (each discharge rod is to be supplied with 02 nos. earting clamps), insulated tee junction- insulated tee junction drg no. eti/ohe/sk/481 and re/33/p/530 or latest (the cable should have an insulated tee junction and the tee clamp should be of brass covered in clamp casing of ebonite material). and whole assembly to be supplied in rugged canvas bag and all shall be as per rdso specification no. eti/ohe/51 (9/87) with latest a and c slip no. 1 (10/92) or latest , and additional part required with each discharge rod to be supply. (1) 01 nos. insulated tee junction. (2) 01 nos. top clamp made of copper suitable for 36 to 50 mm bus bar and also suitable 10 -20 mm dia conductor, (3) 01 nos. spare earthing clamp and. (4) special instruction- 1. discharge rod cable lugs should be made of copper. 2. the cable should have double insulation, a cross- section of 40 sq mm, and 248/0.45 mm strands. 3. the discharge rod should be strong enough to prevent swaying or breaking during maximum extension. every nut and bolt used in the discharge rod must include a washer and spring washer to ensure secure fastening. 5. after the award of the p.o., the firm must ensure approval of one sample of the discharge rod from the consignee before rites inspection. 6. the length of cable from the earthing clamp to top clamp shall not be less than 12.5 mtr. in the cable an insulated tee junction shall be provided at a distance of about 3.5 mtr from the earthing clamp. from this insulated tee junction another piece of cable not less than 1.50 m long shall be provided at the end of which other earthing clamp shall be provided. 7. the galvanized steel tube (threaded) used for coupling of pieces of discharge rod should be at least 20 cm or more as required to prevent swaying of pole assembly during erection at site. also at every 5 cm apart two nos steel rivet is required to be provide on galvanized steel tube ( for preventing the galvanized steel tube from coming out from each discharge rod pole end). i.e. about 08 nos. or more steel rivet as required per galvanized steel tube is to be provided for proper fastening of galvanized steel tube inside the each pole of discharge rod. (warranty period- 30 months after the date of delivery). [ warranty period: 30 months after the date of delivery ]