Get complete information related to latest Iv Tester Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Iv Tester Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Iv Tester Tenders.
Tender For supply of repair of launch x-431 pro scan tool , repair of hyd jack 10 ton , repair of 40 kva alternator , repair of air compressor for pneumatic tools , repair of elak multipurpose auto elect test bench
Tender For corrigendum : supply of equipment for logistics department - paper tearing test measuring range 0 to 1000 mn capacity resolution 0.1 mn indication error 1 % tearing arm 104 1 mm tearing angle 27.5 0.5 tearing distance 43 0.5 mm, paper puncture testing machine energy range of weights - 6, 12, 24 joule per meter accuracy - 2% within full range release angle of pendulum - 90 display - led (digital) 7 segment power - 220v, 50hz,single phase highlights: sample holder - 1 pendulum release mechanism -manual material -mild steel finish - powder coated havel gray & gray combination finish and bright chrome/zinc plating for corrosion resistant finish, weighing machine max capacity (max) maximum load the scale can measure. (3 kg ), min capacity (min) minimum load required for accurate measurement. (0.25 kg), 0.1 g 1 g resolution, sling psychrometer, bursting strength tester capacity: commonly 0 40 kg/cm . accuracy: +or -1 % of the full range (often within 10% to 90% of capacity). resolution: 0.1 kg/cm . operation: microprocessor-based, digital display (lcd/led) with peak hold test fluid: glycerin (approx. 98% purified). power requirement: 220v, single phase, 50 hz. memory. clamping: pneumatic or manual, often with 1/4 hp motor. fluid displacement rate: 95 + or 5 cc/minute., digital micrometer (0-25mm with least count 0.0010) (0 25 mm, 0.001 mm), digital vernier caliper (0-150mm)
Tender For supply of existing pipeline disconnectio , disman of pcc chiseling pneumatic hammer , disman of concretercc,cuttingof reinf , exca of earthsoft rock,cutting,clearing , removal of 200 kl tank , torsteel reinforcement , supply and fabofdishend shellplate , supplyofstructuralsteel and fabric , supply and installationofnozzles , supply and installation of sump , supply and ins. oftank manholes , sand blasting of tank , painting of tank internal , painting of tank external with piping , tank hydro testing after fabrication , instln of tank underground,180kl , tankcalibration and hydrotesting , pipinginchmeter laying ss304 , welding of pipeline , removal of sand murram soil , sand filling , sply and layg of concrete pcc,ratio , sup and lay of rccmixing test , sup and lay rr masonry,subandsuper str , construction of new earth pit
Tender For bid to ras supply of curve , space heater with thermostat , led 11w with door switch phillips , power switch with socket 5 15a 240 vac , earth bus bar 25x6 mm al , fan 4 , louvers 6 ip 55 suitabe , single front fixed type non compartmentalised ip 65 with canopyr size 1890 h x 1600 w x 450 d mm with 15mm antivibration pad and 75 mm base frame , mccb 1no 1nc auxiliary contact , ammeter 96sqmm accuracy cl 1 0 scle 90d with zero adjustable facility , shunt 125 a 75mv , power contactor coil voltage 220v dc with 2no 2nc auxiliary contact for 42 with ac3 duty , thermal overload relay tr2d40353 23 32 a , starting resistance punched stainless steel grid type 2 858 ohm 0 630 ohm 220 v dc , field trimmer resitance variable type non spring type 150 ohm 1 0 a , indicating light cluster led type red green white 22 5 mm 220 v dc , auxiliary contactor 220v dc tca3 dn22md 2 no 2 nc , flush mounted stay put type test push button with 1no 1nc element green colour rcb2 220 v dc , flush mounted spring return type test pb black shrouded 1no 1nc rcb2 ba3 220 v dc , pneumatic type on delay timer 1no 1nc operating voltage 220v dc base mounting ta2 dt2 0 1 30 sec , control terminal suitable for 2 5 sqmm wire 2 5 sqmm , power terminals stud type suitable for 355q mm cable for incoming 2550 mm cable for armature 2 550 mm cable for field dpbb 50 150a kbt 100 100 a katm3c 24 a , 16a 220v dc 4pole 2way selector switch flush mounted , thermostate 30 to 110 , push button projecting type 240v ac , space heater 60 w 240v ac , diode 220v dc , indicator aux supply 85 253vdc input 0 75mv out put 4 20ma with 1no contact , limit switch of the door with 1no 1nc contact 240v ac 6amps , red pilot light 220vdc 22 5mm , green pilot light 220vdc 22 5mm , white pilot light 220vdc 22 5mm , auxiliary relay 220v dc 3no 2nc , time relay 0 1 to 30sec 1n0 1nc on delay , auxiliary relay 220v dc 2no 2nc , latched control relay 220v dc 2n0 2nc , mechanical block anchoring 220 230v ac dc , auxiliary relay 230v ac 2no 2nc , plug in relays 24v dc 4c o contacts , relay base , power contactor 160a dc3 duty 3pole 220v dc coil , auxilary contact block 1no 1nc , power contactor 150a 2pole normally closed 220v dc coil auxilary contact block 2no 2nc , fluorescent light cabnet 220v dc ac 50hz 11w , socket 2p t 16a maxi , blue push button with 1no contact , residual current circuit breaker 25a 30ma 2p rccb , fuse support 20a maxi , fuse link 2a , switch fuse unit 3pole 200a with fuse link 160a lockable type , auxiliary 2c o contact , cooling fan 230v ac 6 , plug in relay 220v dc 2c o contacts , moulded case circuit breaker 160a 3 pole , miniature circuit breaker 2x1 6a dc rating , auxiliary contact 2c o contact , miniature circuit breaker 2x2a dc rating , miniature circuit breaker 2x1a ac rating , miniature circuit breaker 2x2a ac rating , shunt 0 200a 0 75mv , thermostat 30 85 c 1nc , thermostat 30 85 c 1no , earth bus bar 25x6mm , indicator aux supply 85 253v dc ac input 0 75mv out put 4 20ma with 2no contact , auxiliary 1no contact , auxiliary contact 1c o contact , auxiliary contact 1no 1nc contact , earth bus bar 25x6mm for chiller , on delay timer , ipr relay , mcb 2 pole , ct with ammeter , r phase ammeter , y phase ammeter , b phase ammeter , emergency push button epb , energy storage knob mccb ,400a ,4p,tmd based release with rotary handle, aux. contact, dc contactor 300a ,1p normally open type,with 2no+2nc , dc contactor //bid details 2 / 123
Tender For 20 mm bore rubber pneumatic tool hose confirming to is:446/1987; specifications: 1)types of rubber air hose - type 3, 2) working pressure of 1.4 mpa, 3) length of hose should be of 30 mts each, 4) isi marking to be marked on the hose pipe. make: indo, gates, dunlop, ganga, mitras and padmini. note: 1) test report to be furnished during the supply of the hose pipe, 2) one sample shall be supplied and approved by the consignee before bulk supply.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For bid to ras providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 1 installation of dummy flange of size 1200mm to 1400 mm in rcb isolation damper lines for testing of dampers which involves unbolting, removal of r..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 2 carrying out pneumatic leak test of rcb isolation dampers of size 1200mm to1400mm which involves removal of duct section/ manhole for accessing of..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 3 carrying out in-situ service of rcb isolation dampers of size 1200mm to1400mm which involves replacement of gaskets/seals/adjusting disc travel; a..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 4 removal of dummy flange of size 1200mm to 1400mm in rcb isolation damper lines after testing of dampers which involves unbolting, removal of dummy..,repair, main
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needle valves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam
Tender For instrument spare and annual maintenance contract - circular charts:-i) cc-200 (fc-261)range 0-100, ii) 9/d/179/fc-241, range 0-600, iii) 9/d/147/s-8963, range 0-150, iv) 9/d/112/s-3452, range 0-30, disposable pen (red), temperature gauge dial size 6" (h guru) heavy duty with test certificate (mercury filed) :-i) range 0-150 c streight steam 6", ii) range- 0-150 c capillary type (3 meter) bulb length 10" copper/pvc, iii)range 0-300 c streight steam 6", iv) range 0-500 c streight steam 6", vacuum gauge dial size 6" range- 0-30 inch of hg/760 mm bottom feed connection 3/8" bsp, h guru heavy duty with test certificate., pressure gauge dial size 6" bottom feed connection size 3/8" or 1/2" bsp, h guru heavy duty with test certificate :-i) range 0-15 psi 01 kg/cm , ii) range 0-30 psi 02 kg/cm , iii) range 0-60 psi 04 kg/cm , iv) range 0-150 psi 10 kg/cm , v) range 0-300 psi 21 kg/cm , vi) range 0-1030 psi 42 kg/cm /70 kg/cm , pressure gauge, dial size 10" bottom feed connection size 1/2" bsp heavy duty with test certificate:-i) range 0-60 kg/cm h. guru with test certificate, ii) range 0-2 kg/cm2 h. guru with test certificate, pressure gauge for turbines heavy duty with test certificate:-i) 4" dial size side back connection %" bsp range 0-2 kg/cm , ii) 4" dial size side back connection %" bsp range 0-4 kg/cm , iii) 4" dial size side back connection %" bsp range 0-7 kg/cm , iv) 4" dial size side back connection %" bsp range 0-10 kg/cm , teflon coated compensating cable 2 core j type, compensating cable fg/ss 2-core k type, 4 digit digital temperature indicator j & k typ , thermocouple sensor heavy duty:-i. 12" x 8 mm j/k type, ii. 8" x 8 mm j/ k type, iii. 6" x 6 mm j/k type, oil pocket ss 12", 6 digit digital event counter, proximity switch (magnetic sensor) pnp-nc sensing 8 mm,voltage 5-35 vdc, max load 300 ma, on/off pneumatic control valve flange type size- 1" to operate at air pressure 60-80 psi suitable for 20 kg/cm line pressure, on/off solenoid valve for pneumatic valve:-a) air filter " line size female thread, b) air filter with air regulator size 4", digital temperature controller (pid) j & k type, digital tachometer range 0-10000 rpm, 96 x 96 with magnetic sensor., steam flow indicator cum totalizer, drum level controller 4-20 ma input/output model no. 5296at (massibus make), dp transmitter 4-20 ma for boiler drum level, honybell make, positioner for drum level control valve, stroke counter for molasses tank, jumbo digital display with sensor, for juice and water tank, current and previous display size 4" x 4"., ma & mv source meter for temp. indicator calibration, pressure transmiter model tsc 01, range 0 to 40 bar, output 04-20 ma, accuracy 0.25% fs, pressure transmiter model ks-e-e-e b02u-m-v, range 0 to 2 bar, output 04-20 ma, supply 9-32 vdc, port g1/4e, syphon pipe s.s. 304 :-(i) u type, (ii) q type, pressure gauge, model en837-1, ss-316, dail size 6", bottom feed connection size 1/2" bsp, heavy duty with test certificate (tempsens make) :-i) range 0-6 kg/cm , ii) range 0-10 kg/cm , iii) range 0-21 kg/cm , iv) range 0-42 kg/cm , pid controller, size 96 96, model no. dc 1040, make honey bell, pressure recorder range, h-guru make, with test certificate (heany duty) with pipe stand mounted ", socket- ", size 10" :-(i) 0-1 kg./cm2, (ii) 0-2 kg./cm2, (iii) 0-10 kg./cm2, orifice with assembly (nipple), inlet pressure 21 kg/cm , outlet pressure 21 kg/cm , inlet temp. 350 c, outlet temp. 350 c, line size 4", drum level transmitter, range 400 to 400 in h2o, (make- honey bell), steam pressure transmitter, range 14.7 to 3000 psi, (make- honey bell), hade mounted thermocouple, length 450 mm, k-type duplex type, with test certificate (heany duty), signal isolator singal input 4-20ma, double output 4-20ma, repair & calibration work with amcsuper-heated wash water temp. controlling system- 01 no., d-super heated exhaust steam temp. controlling system- 01 no., temperature control system of transit heater for c/f machin