Get complete information related to latest J Bracket Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic J Bracket Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding J Bracket Tenders.
Tender For supply of electroplated pin for equalising stay (bolster bracket end) drawing no.:- icf drg.no- 32905029, alt (nil) item-1 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of elb gate boom section-1 from g.i. sheet octagonal shape with holding bracket, spot welded sleeve & ss nut & bolt as per specification no. rdso/spn/208/2012 version 2.0 or latest as per drawing no-rdso/s11600 ver 2.0 of g.i. boom. note: inspection by third party. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For providing and erecting led street light/flood light, pole box, bracket, cables, indoor lights, fan, dbs, point wiring and dismantling of existing old materials and other electrical works at gandhinagar pool. (dist.: gandhinagar).
Tender For supply of hydraulic pusher 60ton for cbc draft gear removal arrangement, having operating pressure 250kg/sq.cm, cylinder bore dia:125mm, ram stroke: 90mm and closing height-190mm, pump 3 cc/stroke and maximum pressure 500kg/sq.cm. one set consist of 04 items-(1)hydraulic pusher cylinder 60ton- 1no./set, (2)high pressure hydraulic hand pump 01 no/set, (3)pusher assembly bracket-01no/set, (4)high pressure hydraulic hose-3mts/set, (5)one set handle extra (6)all rubber items for three phase ac loco. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of four lane flap or swing barriers including one wider lane , client pc with server , face terminal , access bracket , sixteen port poe switch , tcp ip based smart access controller 4 door , central management software , installation and commissioning charges , deinstallation and buy back , concealed cabling work of total system , power supply , enclosures for controllers , 4 u wall mount rack , cost of civil works involved in the project , comprehensive amc charges for second year , comprehensive amc charges for third year , comprehensive amc charges for fourth year , comprehensive amc charges for fifth year , comprehensive amc charges for sixth year
Tender For supply of belt tension bracket assembly as per drg. no. t-0-3-659/col.-3, alt. d or latest, item 10,11,12,13 in assembled condition. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of preset air filter and regulator lubricator (frl) unit 1/4 inch,at 3 bar pressure with bracket and fasteners designed for pressurised flushing system, as per rdso spec. is/rdso-cg/0005/2025.make: ckd/parker/festo/smc/norgren/janatics/spac [ warranty period: 42 months after the date ofdelivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and getting out in an