Web Analytics Made Easy - StatCounter

Jet Mill Tenders

Get complete information related to latest Jet Mill Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Jet Mill Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Jet Mill Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45692458 Due date: 15 Jul, 202615 Jul, 2026 75.91 Lacs
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r

State Government

CTN :44316428 Due date: 27 Apr, 202627 Apr, 2026 5.86 Crore
Tender For corrigendum : supply of 73 reagents d d - alat gpt diagnostics testing reagents , albumin diagnostics testing reagents , alkaline phosphatase chemical , amylase diagnostics testing reagents , asatgot diagnostics testing reagents , bilirubin direct diagnostics testing reagents , bio cal diagnostics testing reagents , bio norm diagnostics testing reagents , bio path diagnostics testing reagents , calcium a diagnostics testing reagents , cholesterol diagnostics testing reagents , creatinine diagnostics testing reagents , crp diagnostics testing reagents , g-glutamyl transferase diagnostics testing reagents , glucose diagnostics testing reagents , hdl cholesterol direct diagnostics testing reagents , lactate dehydrogenase ldh , micro albumin diagnostics testing reagents , total protein diagnostics testing reagents , triglyceride diagnostics testing reagents , urea diagnostics testing reagents , uric acid diagnostics testing reagents , bilirubin total diagnostics testing reagents , cleanser for biochemistry fully auto analyser , ra factor diagnostics testing reagents , serum iron for fully automated biochemistry , tibc for fully automated biochemistry analyzer , 553 lyphochek hba2f bi level kit for hplc , 740 lypochek diabetic control . , dual kits for hplc and hba1c diagnostics testing reagents , h clean diagnostics testing reagents 5-part cell counter , h560 dil diagnostics testing reagents 5-part cell counter , h560 lyse 1 diagnostics testing reagents 5-part cell counter , h560 lyse 2 diagnostics testing reagents 5-part cell counter , trilevel control l, n, h diagnostics testing reagents , activated prothrombin time fsr , prothrombin time fsr diagnostics testing reagents , electrolyte reagents cal a 350 ml, cal b 150 ml, , deprotiniser ise kit for electrolyte analyser , ifs solution kit for electrolyte analyser , alkaline phosphatase diagnostics testing reagents , bilirubin total and direct diagnostics testing reagent , erba wash diagnostics testing reagents , hdl diagnostics testing reagents semi , sgot diagnostics testing reagents , sgpt diagnostics testing reagents , serum iron and tibc for semi automated , 21341 gn test id card anti-bacterial , 21342 gp test id card auto bacterial , 21343 yst test id card auto bacterial , 21346 nh test id card auto bacterial , 410851 -3d fa plus bact alert automated blood culture , 410852 - 3d fn plus bact alert automated blood culture , 410853 - 3d pf plus bact alert automated blood culture , ast n235 ast card auto bacterial identification system , ast n405 ast card auto bacterial identification system , ast n406 ast card auto bacterial identification system , ast n407 ast card auto bacterial identification system , ast p628 ast card auto bacterial identification system , ast st03 ast card auto bacterial identification system , ast ys08 ast card auto bacterial identification system 21341 gn test id card anti-bacterial identification system, 21342 gp test id card auto bacterial identification system, 21343 yst test id card auto bacterial identification system, 21346 nh test id card auto bacterial identification system, 410851 -3d fa plus bact alert automated blood culture system, 410852 - 3d fn plus bact alert automated blood culture system, 410853 - 3d pf plus bact alert automated blood culture system, 553 lyphochek hba2f ( bi level) kit for hplc bio rad d 10, 740 lypochek diabetic control, activated prothrombin time (fsr) diagnostics testing reagents coagulometer, alat (gpt) diagnostics //bid details2 / 60

Central Government/Public Sector

CTN :44347961 Due date: 31 Mar, 202631 Mar, 2026 NA
Tender For corrigendum : supply, installation and commissioning of air jet mill bench top model sajm 50 lab scale with one year onsite warranty for nit warangal
 Loading, Please wait...

Connect us via What's Up