Web Analytics Made Easy - StatCounter

Jointing Item Tenders

Get complete information related to latest Jointing Item Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Jointing Item Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Jointing Item Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Co-operative

CTN :40232581 Due date: 20 May, 202520 May, 2025 NA
Tender For supply of packing and jointing items for season 2025-26

CTN :40222106 Due date: 02 Jun, 202502 Jun, 2025 42.37 Lacs
Tender For supply of electrical materials for the repair and maintenance of street lights as per the boq - t-5 power/energy saver 2x24w choke, t-5 power/energy saver 24w ftl tuberod, 2x24 t5-holder, t5 power saver 2x24 fixture acrylic transparent cover, t5 power saver 4x24 fixture acrylic transparent cover, 150w hpsv choke, 150w hpsv lamp, capacitor 33mfd 250vac 50 hz, electronic ignitor suitable for 150w hpsv lamps, 150w holder, led driver 50w bis certified, led mcpcb plate 50w, led mcpcb plate 100w, led mcpcb plate 150w, supplyingof isi marked and approved make of moulded case circuit breaker(mccb) suitable for 3phase,3pole,50hz,415 volts, ac supply with respective interrupting capacity(ka) at 415 volts cited against their range standard conforming to is - 8828: 8.1mccb with breaking capacity 25 ka at 415 v: current rating -125 amps & 70% -100% adjustable, supply, installation, testing and commissioning of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light sub feeder panels - type 2 pluggable spd 3+1, rating l-n/n-pe uc 255/320 v in 30/60ka ka, lmax 30ka/60 ka, up 1.5kv, supplying of isi marked and accepted standard of miniature circuit breaker(mcb)ofcseries suitable for 240/415volts,50cycle,10 ka value ac supply confirming to is:8828:1996,iec:60898 :2002 but without enclosures: single pole 63 amp., astronomical timer with dst feature, contactor 3 pole 90 amp 50hz 415volts with no-nc contacts, tpn connector 150a, supply of approved make powder coated sheet steel encloser spn mcb db inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator): 8 way double door, supply, installation, testing and commissioning of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light - type 2 pluggable spd 1+1, rating l-n/n- pe uc 230/400 v in 5 ka, imax 10 ka, up 1.2kv, led batten tubelight 20w, supplying of approved make tpn mcbdb metal double door with provision for fpmcb/isolator/rccb/rcbo as incomer and sp mcbs as outgoing inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator ): 8 way (8+24), 8 sq.mm multistrand pvc insulated copper wire bundle 90mtr, 1.sq.mm aluminium single core wire bundle of 100mtr. isi marked, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 2-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 4-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 1-core isi marked with alu. stranded/solid conductor: 25sq.mm unarmoured, wooden ladder 21ft, toolkit set consisting of different sizes l-keys, screw drivers, testers and plier set., taperoll box consisting of 30pcs (conforms to is: 7809 (part 3, sec 1),self extinguishing,protects from electrolyt

CTN :39978574 Due date: 02 May, 202502 May, 2025 20.78 Lacs
Tender For corrigendum : supply of spares/miscellanious items for gis pahalgam for providing reliable power supply during sanjay 2025. - split inverter ac 1.5 ton 5 star hot and cold with avr and other accessories of standard make (for gis pahalgam), servo voltage stabilizer three phase oil cooled p-p 190-450 v : p-n:110-260 v ( with t-oil) , 15 kva (100 ltr. oil capacity), 36v 100ah float cum boast battery charger with full wave rectification for 220v single phase, 50hz ac input supply for (gis pahalgam), 33 kv single core indoor cable kit ( plug in tremination type and screened seperable connectors ) for 400 mmsq cable for gis compatible substaion (brand:- euromold, nexans, raychem etc), 33 kv single core outdoor type cable kit for 400 mmsq, 11 kv single core indoor cable kit ( plug in tremination type and screened seperable connectors ) for 630 mmsq cable for gis compatible substaion (brand:- euromold, nexans, raychem etc)for gis substaion panel mounted, 11 kv three core indoor cable kit ( plug in tremination type and screened seperable connectors ) for 400 mmsq cable for gis compatible substaion (brand:- euromold, nexans, raychem etc)for gis substaion panel mounted, 33 kv current transformer outgoing (33 kv, 1 , multi ratio multi core 600-300/1a, indoor type) (1 no. per ) for gis compatible 33/11kv station panel mounted, 33 kv current transformer incommer (33 kv, 1 , multi ratio multi core 900-600/1a, indoor) (1 no. per ) for gis compatible 33/11kv station panel mounted, 11 kv current transformer outgoing (11 kv, 1 , multi ratio multi core 200-400/1a, indoor) (1 no. per ) for gis compatible 33/11kv station panel mounted, 11 kv current transformer incommer (11 kv, 1 , multi ratio multi core 900-600/1a, indoor) (1 no. per ) for gis compatible 33/11kv station, 11 kv current transformer (11 kv, 1 , multi ratio multi core 600-300/5a, indoor) (1 no. per ) compatible to hartek panels at ais pahalgam, 33 kv current transformer for auxillary (33 kv, 1 , 30/1a, indoor) (1 no. per ) for gis compatible 33/11kv station panel mounted, potential transfromer 33kv/110v (1 , multi core indoor) (1 no. per ) for gis compatible station panel mounted, potential transfromer 11kv/110v (1 , multi core indoor) (1 no. per ) for gis compatible station panel mounted, over current/earth fault (3 o/c and 2 e/f relay abb type for gis compatible 33/11kv substation, providing and fixing 3 layer pp-r (poly propylene random copolymer) pipes conforming to is: 15801, uv stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all pp-r plain and brass threaded polypropylene random fittings. this includes testing of joints complete as per direction of engineer-in?charge. internal work-exposed on wall with clamps at 1.00 meter spacing pn-16 pipe , 25mm od(sdr-7.4) for replacement of damaged pipiline. (for ais and gis )

Central Government And Public Sector

CTN :40119127 Due date: 26 Apr, 202526 Apr, 2025 NA
Tender For electric cabling service - 3 phase heavy duty electric wiring xlpe insulated working voltage form 415 v to 11 kv as per is 1554 along with associated items and civil work as per schedule of work attached; copper and aluminium coth conductor material as per schedule of work-1 supply, laying and testing cable xlpe insulated ,screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sq mm 3 1/2 core. rm 280 2 excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, or for shafts, wells, cesspits, manholes, pier holes, etc. and not exceeding 10 sqm on plan and getting out in soft /loose soil complete all as specified and as directed cum 60.75 3 returning filling including spreading leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and as directed. cum 60.22 4 removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. cum 0.53 5 supply and laying ldpe pipes 50 mm dia with all fitting ,laid in ground for crossing the cables across the road by cutting existing road , under floor ,wall by cutting existing floor and making good the road /floor and wall surface after laying of pipe . rm 270 6 cement concrete 1:3:6 type c-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete for making foundation for mounting flood light /bollard light fitting/finishing of roads/floors etc . cum 4.05 7 m &l for cutting of road /floor surface 30cm girth, up 45 cm width for croosing the pipe line /laying of cable acroos the road all as specified and directed. rm 30 8 s & f distribution boards epoxy powder coated tp & n (vtpn mccb db) 8 way ,415 volts ,fabricated from minimum 1.6 mm thick crca sheet and fixed/ flush to wall and suitable for universal mounting with 250 amps fully insulated copper bus bar for each phase and 02 neutral shrouded bar ,2 earth bar and cable tie for cable management with reversible door for ip-43 db,s protection, suitable for fixing fp mccb 100/125 amps as incomer complete all as specified and directed. note: suitable mccb and outgoing mcbs will be measured separately under relevant items of this schedule each 1 9 s & f mccb ,4 pole 100 a , 415 volts with rupturing capacity 16 ka with thermal-magnetic release and adjustable overload setting of following capacity complete all as directed. each 1 10 s & f bus bar chamber with 4 nos copper busbar 150 amps including mccb 100a 16ka 415 volts each 1 11 s & f sub main wiring with 4x16 sqmm +1 x 10 sqmm run pvc insulated unsheathed frlsh cable 1100 volt grade, with multi stranded copper conductor drawing in concealed pvc conduit not less than 25mm dia complete all as specified and directed. rm 50 12 s & f sub main wiring with 2x4 sqmm +1 x 4 sqmm run pvc insulated unsheathed frlsh cable 1100 volt grade, with multi stranded copper conductor drawing in concealed pvc conduit not less than 25mm dia complete all as specified and directed. rm 200 13 s & f modular rectangular block for mounting,modular switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175mm x 175 mm and 50 mm deep each 25 14 supply and fix modular switch 1 way 16a, 1 module with indicator lamp each 25 15 supply and fix modular socket 6a/16a, 2/3 pin combined 2 module each 25 16 material and labour for earthing with galvanised steel earth plate electrode 60cmx60cmx 6mm thick burried directly in ground (earth pit not less than2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 32 x 6 gi strip by means of nuts,bolts,check nuts & washers of galvanized iron or steel,protected by 15mm bore light grade galvanised iron pipe and connected to

State Government

CTN :40071789 Due date: 19 May, 202519 May, 2025 NA
Tender For providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above supplied stab

Central Government/Public Sector

CTN :40065714 Due date: 02 May, 202502 May, 2025 9.55 Lacs
Tender For supply of spares for sait mine line make starter - cu bus bar, pvc slvd 25x8 wand cable clamp cb480kwbbr400 , busbar support bs480kwbs50 , isolator bush nylon ib480kwbsh3 , limit switch for isolator lsfi480kwei , ht pt fuse htptf480kwavt , ht pt fuse support htptfs480kwbs45fs , vacuum contactor 3 point 3 kv, coi l 220v ac vc480kwsavac4 , closing coil of vacuum contractor ccvc480kwvcccc , vcc aux point contact vac480kwvccacb , 1 ph pt 3 point 3 110v i 110v ac 1phpt480kwb2spf2v , current transformer ct480kwstd , main fuse mf480kwstd , control fuse cf480kwns , earth leakage relay, 220vac wand cbt 80mm2 elr480kwelm8 , ammeter am480kwpa1100 , push buttons actuator green and red pba480kwpb , led indicator lamp green lilg480kw110vac , led indicator lamp red lilr480kw110vac , led indicator lamp amber lila480kw110vac , aux contactor 2no plus 2nc 220v ac ac2nonc480kwka , electronic timer et480kwbo2aodt5 , cluster indicating lamp cil480kwlab9 , control circuit breaker ccb480kwbocsmbs2c6 , thermal o and l with spp tol480kw3ua50001f , ht bushing for outgoing htbo480kwhttb10

Central Government And Public Sector

CTN :39965193 Due date: 30 Apr, 202530 Apr, 2025 NA
Tender For supply of 32 ampere lbs incoming cable size- 1r x 3c x 10sqmm , 32 ampere lbs-incoming cable size-1r x 3c x 16sqmm , 32 ampere lbs-incoming cable size-1r x 3c x 2.5sqmm , 32 ampere lbs-incoming cable size-1r x 3c x 25sqmm , 32 ampere lbs-incoming cable size- 1r x 3c x 35sqmm , 32 ampere lbs-incoming cable size- 1r x 3c x 4sqmm , 32 ampere lbs-incoming cable size- 1r x 3c x 50sqmm , 32 ampere lbs-incoming cable size- 1r x 3c x 10sqmm , 63 ampere lbs-incoming cable size- 1r x 3c x 25sqmm , 63 ampere lbs-incoming cable size-1r x 3c x 35sqmm , 63 ampere lbs-incoming cable size- 1r x 3c x 50sqmm , 63 ampere lbs-incoming cable size- 1r x 3c x 70sqmm , 63 ampere lbs-incoming cable size- 1r x 3c x 95sqmm , 100 ampere lbs-incoming cable size- 1r x 3c x 120sqmm , 100 ampere lbs-incoming cable size- 1r x 3c x 70sqmm , 100 ampere lbs-incoming cable size- 1r x 3c x 95sqmm , 125 ampere lbs-incoming cable size- 1r x 3c x 120sqmm , 125 ampere lbs-incoming cable size- 1r x 3c x 150sqmm , 125 ampere lbs-incoming cable size- 1r x 3c x 185sqmm , 125 ampere lbs-incoming cable size- 1r x 3c x 240sqmm , 125 ampere lbs-incoming cable size- 1r x 3c x 50sqmm , 125 ampere lbs-incoming cable size- 1r x 3c x 70sqmm , 125 ampere lbs-incoming cable size- 1r x 3c x 95sqmm , 125 ampere lbs-incoming cable size- 2r x 3c x 120sqmm , 125 ampere lbs-incoming cable size- 2r x 3c x 150sqmm , 125 ampere lbs-incoming cable size- 2r x 3c x 300sqmm , 125 ampere lbs-incoming cable size- 2r x 3c x 95sqmm , 160 ampere lbs-incoming cable size- 1r x 3c x 150sqmm , 160 ampere lbs-incoming cable size- 2r x 3c x 95sqmm , 250 ampere lbs-incoming cable size- 2r x 3c x 120sqmm , 250 ampere lbs-incoming cable size- 2r x 3c x 150sqmm , 250 ampere lbs-incoming cable size- 2r x 3c x 185sqmm , 250 ampere lbs-incoming cable size- 2r x 3c x 240sqmm , 250 ampere lbs-incoming cable size- 2r x 3c x 300sqmm , 250 ampere lbs-incoming cable size- 3r x 3c x 150sqmm , 250 ampere lbs-incoming cable size- 3r x 3c x 185sqmm , 400 ampere lbs-incoming cable size- 1r x 3c x 300sqmm , 400 ampere lbs-incoming cable size- 3r x 3c x 150sqmm , 400 ampere lbs-incoming cable size- 3r x 3c x 185sqmm , 400 ampere lbs-incoming cable size- 3r x 3c x 240sqmm , 400 ampere lbs-incoming cable size- 3r x 3c x 240sqmm outgoing cable size- 2r x 3c x 70sqmm copper , 400 ampere lbs-incoming cable size- 3r x 3c x 300sqmm , 400 ampere lbs-incoming cable size- 4r x 3c x 185sqmm , 400 ampere lbs-incoming cable size- 4r x 3c x 240sqmm , 400 ampere lbs-incoming cable size- 4r x 3c x 300sqmm , 400 ampere lbs-incoming cable size- 6r x 3c x 240sqmm , 630 ampere lbs-incoming cable size- 3r x 3c x 240sqmm , 630 ampere lbs-incoming cable size- 6r x 3c x 240sqmm

Co-operative

CTN :39958115 Due date: 21 Apr, 202521 Apr, 2025 NA
Tender For 3272/supply of packing and jointing items

Central Government/Public Sector

CTN :39880815 Due date: 29 Apr, 202529 Apr, 2025 NA
Tender For supply of double hole lug terminal for tm outgoing cable to wm/dsl/aii drawing no. de mu/et-1/a for 700/1400 hp demu/dpc [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up