Get complete information related to latest Kenter Shackle Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Kenter Shackle Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Kenter Shackle Tenders.
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking
Tender For corrigendum : supply of 26mm dia lifting/pickup chain+2 shackles+1 master link of 40mm dia , galvanised , length-2mtr , mbl-55t , item no-15 , for spm , 26mm dia snubbing chain c/w 2 shackles and master link assembly , galvanised , length-11mtr , mbl-55t , item no-13 , for spm , 200 tone mooring haswer shackle of 18 inch jaw , modified ocimf chafe chain a , generally inaccordance with ocimf 2007 , manufactured from76mm nom. dia. grade r4 material in accordance withiacs w22 and consisting of 1 x special end link1 x enlarged link30 x common links1 x 67mm kentershackle (grade u3) , safe workingload 250 tonnesproof load 482 tonnes , minimum break load 612 tonnes. , ocimf chafe chain c , in accordance with ocimf 1993 , manufactured from 54mm nom. dia. grade u3 material and consisting of 1 x special end link , 1 x enlarged link , 12 x common links , 1 x 60mm common link , 1 x oblong plate1 x 42t pick-up shackle-safe working load 100 tonnes , proof load 162 tonnes , minimum break load 231 tonnes. , hawser timble 18 inch /21 inch stainless steel reusable bellmouth thimble complete with ss roll the roll bored suitable for 18 inch x 200 t swl wide jaw shackle for spm
Tender For supply of angle iron 50 x 50 x 6mm , angle iron strip 6 inch for fastening of bolts , angle iron strip bolts for connecting strip to picquet , 3.20mm dia chain link fencing and size of mesh 3 inch , barbed wire 2.2mm dia length 1000m x 3 total 3000m , construction material and labour , transport charges
Tender For bid to ras corrigendum : supply of anchor chain with accessories cable clench anchor spares for mpv project yard nos 3050 to 3057 d d -no - 3052 , documentation as per sotr for yard no - 3052 , anchor-2475 kg,stockless hhp anchor ty-b for yard no - 3053 , anchor chain cable_247.5 m dia for yard no - 3053 , cable clench for yard no - 3053 , swivel piece for yard no - 3053 , kenter type joining shackle for yard no - 3053 , kentershackle disengaging device for yard no - 3053 , pin punch for yard no - 3053 , shackle punch for yard no - 3053 , chain hooks for yard no - 3053 , anchor hammers for yard no - 3053 , spare anchor shackle for yard no - 3053 , spare anchor pin for anchor shackle for yard no - 3053 , spare pins for kentershackle for yard no - 3053 , inspection certificates for yard no - 3053 , documentation as per sotr for yard no - 3053 , anchor-2475 kg,stockless hhp anchor ty-b for yard no - 3054 , anchor chain cable_247.5 m dia for yard no - 3054 , cable clench for yard no - 3054 , swivel piece for yard no - 3054 , kenter type joining shackle for yard no - 3054 , kentershackle disengaging device for yard no - 3054 , pin punch for yard no - 3054 , shackle punch for yard no - 3054 , chain hooks for yard no - 3054 , anchor hammers for yard no - 3054 , spare anchor shackle for yard no - 3054 , spare anchor pin for anchor shackle for yard no - 3054 , spare pins for kentershackle for yard no - 3054 , inspection certificates for yard no - 3054 , documentation as per sotr for yard no - 3054 , anchor-2475 kg,stockless hhp anchor ty-b for yard no - 3055 , anchor chain cable_247.5 m dia for yard no - 3055 , cable clench for yard no - 3055 , swivel piece for yard no - 3055 , kenter type joining shackle for yard no - 3055 , kentershackle disengaging device for yard no - 3055 , pin punch for yard no - 3055 , shackle punch for yard no - 3055 , chain hooks for yard no - 3055 , anchor hammers for yard no - 3055 , spare anchor shackle for yard no - 3055 , spare anchor pin for anchor shackle for yard no - 3055 , spare pins for kentershackle for yard no - 3055 , inspection certificates for yard no - 3055 , documentation as per sotr for yard no - 3055 , anchor-2475 kg,stockless hhp anchor ty-b for yard no - 3056 , anchor chain cable_247.5 m dia for yard no - 3056 , cable clench for yard no - 3056 , swivel piece for yard no - 3056 , kenter type joining shackle for yard no - 3056 , kentershackle disengaging device for yard no - 3056 , pin punch for yard no - 3056 , shackle punch for yard no - 3056 , chain hooks for yard no - 3056 , anchor hammers for yard no - 3056 , spare anchor shackle for yard no - 3056 , spare anchor pin for anchor shackle for yard no - 3056 , spare pins for kentershackle for yard no - 3056 , inspection certificates for yard no - 3056 , documentation as per sotr for yard no - 3056 , anchor-2475 kg,stockless hhp anchor ty-b for yard no - 3057 , anchor chain cable_247.5 m dia for yard no - 3057 , cable clench for yard no - 3057 , swivel piece for yard no - 3057 , kenter type joining shackle for yard no - 3057 , kentershackle disengaging device for yard no - 3057 , pin punch for yard no - 3057 , shackle punch for yard no - 3057 , chain hooks for yard no - 3057 , anchor hammers for yard no - 3057 , spare anchor shackle for yard no - 3057 , spare anchor pin for anchor shackle for yard no - 3057 , spare pins for kentershackle for yard no - 3057 , inspection certificates for yard no - 3057 , documentation as per sotr for yard no - 3057
Tender For corrigendum : 15/edc(blp)/2026-27 - loading, unloading and safe cartage of the following materials from electricity store centre, balrampur to the work site/dump site (distance up to 50 km), st poles (11 mtr long), pcc poles (8.5 mtr long), acsr weasel conductor, lt abc 3x120+1x95+1x16sq.mm., 100 kva t/f, other line materials, erection of single st poles (11 mtr long) for 11 kv/l.t. line alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site, erection of single pcc poles (8.5 mtr long) for 11 kv/l.t. line alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site, erection of sectional double pole sectional pcc pole (8.5 mtr long pcc pole) alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site., earthing of pole as per uppcl/resspo norms.., erection and grouting of stay sets alongwith complete fittings. cement, sand & brick ballast provided by the contractor at his own cost., grouting of poles with 1:4:8 cc ratio of cement, sand & brick ballast, backfilling of pits with mud completely.all required materials provided by the contractor at his own cost., laying, stringing, sagging & binding of conductors of 11 kv in 3 phase, 3 wire line with jumpering (where as required), laying, stringing & sagging of 3x120+1x95+1x16sq.mm. abc cable up to proper sag for the following size cable, construction of 11/0.4 kv s/s for 100 kva t/f with mounting and fitting of t/f on plinth/double pole with proper fitting of all acessories and connecting with all circuit including earthing of t/f fitting with all accessories., earthing of distribution t/fs for body & neutral upto water level with gi pipe of 1.5" dia. including gi strip size 35x6 mm. (all material will be supplied by contractor)., decentralized materials:-providing and fixing of following materials as per sanctioned estimate/package as per resspo u.p.p.c.l. drawing/ norms.(where is required)., suspension clamp with i hook, i hook, suspension clamp with i hook, i hook, lt fuse set., lt pvc cable al 1x120sq.mm., lt pvc cable al 1x400sq.mm., lug sutable for 250 kva, suspension clamp with i hook, i hook, lt fuse set., lt pvc cable al 1x120sq.mm., lt pvc cable al 1x400sq.mm., lug sutable for 250 kva