Get complete information related to latest Kerosene Oil Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Kerosene Oil Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Kerosene Oil Tenders.
Tender For tender for supply of lab chemical - diphenyl carbazide ar gr details specification shall be as per attached nit , dimethyl amino benzal dehyde pdab details specification shall be as per attached nit , boric acid crystals details specification shall be as per attached nit , laboratory chemicals a acid oxalic ar gr details specification shall be as per attached nit , silver nitrate details specification shall be as per attached nit , lab n n napthyl ethylene diammine di hyd details specification shall be as per attached nit , brucine ar details specification shall be as per attached nit , lab m mercury ii thiocyanate details specification shall be as per attached nit , chromotropic acid details specification shall be as per attached nit , lab patton reeders reagent details specification shall be as per attached nit , diacetyl monoxime ar details specification shall be as per attached nit , lab i indigo carmine details specification shall be as per attached nit , eriochrome black t indicator details specification shall be as per attached nit , bismuth nitrate details specification shall be as per attached nit , lab m methyl orange details specification shall be as per attached nit , urease active meal details specification shall be as per attached nit , di phenyl amine details specification shall be as per attached nit , lab f ferric citrate details specification shall be as per attached nit , lab tryptone bacteriological details specification shall be as per attached nit , cupric sulphate details specification shall be as per attached nit , lab s starch details specification shall be as per attached nit , lab s sodium oxalate details specification shall be as per attached nit , hexamine ar hexamethylene tetra amine details specification shall be as per attached nit , sulfamic acid details specification shall be as per attached nit , bromocresol green indicator details specification shall be as per attached nit
Tender For supply and installation of laboratory equipment experimental setup for fyimp ug practical classes at the department of physics, gauhati university - laboratory equipments/experiment set ups, experiment name: to verify the law of malus for plane polarised lighttechnical specifcations:i. light source: - led: 532 nm or 635 nm ( 2 nm stability), 1 5 mw adjustable output. - unpolarized (extinction ratio >500:1). - collimated beam (divergence 0.5 mrad); qty-1ii. polarizers- glan-thompson or polymer film. - extinction ratio 10 :1 @ operating wavelength.- mounted in 50 mm rotation holders.; qty-2iii. rotation stage- motorized analyzer rotation (0.05 resolution). - accuracy: 0.1 . - range: 0 360 (continuous).; qty-1iv. photodetector- silicon photodiode (400 1100 nm). - linearity: r 0.999 (0.1 w 5 mw).- digital readout: 0.1 w resolution.; qty-1v. optical bench-- anodized rail ( 60 cm) with kinematic mounts. - vibration-damping feet.; qty-1, experiment name: to determine thespecific rotation of sugar solution using polarimetertechnical requirementsa.core instrumenti. light source- - sodium d-line (589.3 nm) or tunable led ( 2 nm stability). - output stability: 0.2% drift/hour.ii. polarizer/analyzer- glan-thompson prisms or high-grade polymer film. - extinction ratio 10,000:1 at 589 nm.iii. rotation stage- motorized with 0.001 resolution.- accuracy: 0.005 .- range: -90 to +90 .iv. sample cell-- borosilicate glass tubes with precision ground ends. - path lengths: 0.5 dm, 1.0 dm, 2.0 dm ( 0.01 dm tolerance). - temperature-controlled jacket (5 50 c 0.1 c).v. detector- photomultiplier tube (pmt) or low-noise photodiode. - linearity: r 0.999 over 0.1 w 5 mw rangevi. enclosure- light-tight with vibration damping. - internal black anodized surfaces.b.measurement specificationsi. specific rotation: range: -180 to +180 resolution: 0.001 accuracy: 0.01 ii. concentration-range: 0.01 0.5 g/ml (sucrose in water) detection limit: 0.001 g/mliii. temperature control-stability: 0.1 c at 20 c (standard condition), experiment name: to determine the wavelength and velocity of ultrasonic waves in a liquid (keroseneoil, xylene, etc.) by studying the diffraction through ultrasonic gratinga.core componentsi. ultrasonic generator- - frequency range: 1 10 mhz ( 0.1% stability). - adjustable output: 0 50 w. - digital display (resolution: 0.01 mhz).ii. transducer- piezoelectric (pzt) crystal, resonant at 2 5 mhz. - liquid-coupled design for efficient energy transferiii. liquid cell- optical glass (low thermal expansion). - dimensions: 100 50 50 mm (l w h). - sealed with quartz windows.iv. light source- he-ne laser (632.8 nm, 2 mw) or sodium lamp (589.3 nm). - beam collimation: 0.5 mrad divergence.v. optical system- adjustable slit (10 500 m). - collimating lens (f = 150 mm, 50 mm). - precision rotation stage for detector (0.01 resolution).vi. detection system- photodiode/pmt detector with linear response (400 800 nm). - traveling microscope (0.01 mm resolution) or ccd camera ( 5 mp).b.measurement specificationsi.wavelength ( )range: 0.1 2 mm, resolution: 0.001 mm, accuracy: 1%ii. velocity (v)range: 800 2000 m/s (liquids) resolution: 1 m/s accuracy: 2%iii. diffraction angles- measurement range: 30 resolution: 0.01 , experiment name: to verify the stefans law of radiation and to determine stefan s constanta.core componentsi.black body radiator- cavity-type design (emissivity 0.99). - material: nickel-plated copper.- operating range: 50 c 600 c. - aperture diameter: 10 mm 0.1 mm.ii. heating system- pid-controlled furnace (0 600 c). - stability: 0.5 c at 300 c. - power: 500 w (ac 230v).iii. temperature sensor- type k thermocouple or pt100 rtd. - accuracy: 0.5 c at 500 c (nist-traceable).iv. radiation detector- thermopile sensor (spectral range: 0.3 20 m). - responsivity: 10 v/w.- active area: 10 10 mm .v optical path. - water-cooled collimating tube with baffles.- adjustable aperture to define solid angleb.measurement specificationsi. temperature range100 c 500 c (reso
Tender For supply of hexamathylene tetramine (hexamine) to is 4306/1987. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitt ed: max 8 lacs ]