Get complete information related to latest Key Lock Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Key Lock Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Key Lock Relay Tenders.
Tender For supply of 3 phase scr controller for constant voltage current card , high voltage and phase fail phase sequence reverse card rating 20va , charger dc under voltage circuit of solid state sensing type. rating. aux. supply 12v dc,actuating voltage 242v, resetting voltage 245v , load over voltage circuit of solid state sensing type. rating. aux. supply 12v dc rating actuating voltage 248v, resetting voltage 245v , battery dc under voltage circuit of solid state sensing type. rating. aux supply 12v dc rating actuating voltage 198v resetting voltage 220v , battery dc over voltage circuit of solid state sensing type rating aux. supply 12v dc actuating voltage 300v resetting voltage 296v , load dc under voltage circuit of solid state sensing type rating aux supply 12v dc actuating voltage 198v resetting voltage 220v , load over voltage circuit of solid state sensing type with aux. supply 12v dc actuating voltage 248v resetting voltage 245v , load earth leakage circuit imd of solid state sensing type , static annunciation circuit with accept, reset and test facilities,rating 12v dc , 3 phase full wave controller , filter condenser , circuit for dc contactor , 2 pole 2 way no off cam type auto manual mode selector switch , 3 pole 2 way no off cam type boost equalising mode selector switch , 2 c o plug in type auxiliary relay with base for above lamp,240v ac , 2 c o plug in type auxiliary relay with base for remote alarm contact, rating 12v dc , auxiliary contactors for float boost mode selection with add on block , 4 pole 2 way ac rotary changeover selector switch for ac incoming for 220v 80a charger rating 150a , 4 pole 2 way ac rotary changeover selector switch for ac incoming for 220v 60a charger rating 100a ) /bid number: gem/2025/b/7026551 * /dated: 20-12-2025 & & / bid document1 / 21
Tender For bid to ras bid to ras bid to ras supply of purchase electrical engg lab equipment and machinery items--digital energy meter , portable digital wattmeter single phase , ohms law verification kit , kirchhoff s law verification kit , portable digital ammeter ac , portable digital ammeter dc , portable digital voltmeter ac , portable digital voltmeter dc , resistance in series and parallel training kit , portable digital power factor meter , hydrometer , rlc circuit trainer kit , dc regulated power supply , portable digital wattmeter three phase , digital lcr meter , inverter , battery for inverter , battery charger , portable analog ammeter ac , portable analog ammeter dc , portable analog voltmeter ac , portable analog voltmeter dc , analog multimeter , phase sequence indicator phase indicator , digital tachometer contact cum non contact , current transformer , potential transformer , cathode ray oscilloscope cro , digital earth tester , portable digital power factor meter three phase , portable digital power factor meter single phase , portable digital frequency meter , digital flux meter , thermistor kit , lvdt trainer kit , 3 phase power measurement trainer , analog megger insulation tester , single phase transformer , universal motor , dc servo motor , dc motor starter , ac commutator motor , variac single phase , dc shunt motor shunt generator set , dc shunt motor series generator set , dc motor alternator set , squirrel cage induction motor , slip ring induction motor , single phase capacitor start motor , scot connection transformer , three phase transformer , variac three phase , ac motor starter , stroboscope , synchroscope , synchronous motor 3 phase , single phase resistive load , three phase resistive load , sliding rheostat wire wound10 ohms 1 amp , sliding rheostat wire wound 50 ohms 1 amp , sliding rheostat wire wound 50 ohms 2 amp , sliding rheostat wire wound 100 ohms 1 amp , sliding rheostat wire wound 100 ohms 2 amp , three phase ac to dc rectifier set , digital breakdown voltage tester , inverse time over current relay induction type , earth leakage relay , 3 phase power measurement trainer kit , fuse and mcb tesing kit , inverse time over current static relay , relay testing kit , plc trainer kit
Tender For auction sale of rheostat, 2.5/5a,cfb test set,dimmer state,zfb relay test kit,insulation tester, hand held,multimeter, digital,indicator, phase sequence,ct primary injection test kit,brief case,common meter reading instrument,lock, with key,cable, common meter reading instrument
Tender For provisioning of electrical and mechanical eqpt against ber under ge 862 ews - supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 300 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type(m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 450 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fitting & accessories e.g marking plate, lifting lugs, ci rollers, earthing terminals, cable box including suitable platform as reqd on site complete all as as specified & directed., supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 100 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type (m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 150 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fi