Get complete information related to latest Keypad Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Keypad Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Keypad Tenders.
Tender For supply of prepaid energy meter single phase-keypad based with ciu(consumer interface unit), numberof wires-2, output voltage-240v,50 hz,current-60amp,automatic data storage duration 25 days,wall mounted,class-1, lcd displays, low credit & over loading alarm-yes,ip 51 protection. make-hpl electric and power ltd. new delhi. warranty-12 months. [ warranty period: 12 months after the date of delivery ] ]
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For supply of 5 watt vhf digital walkie talkie set without keypad and without display to spec. no. rdso/spn/tc/107/2018 ver. 2.1, sl. no. 2.3(b). each set will consist of: (1) one [1] no. vhf set with compatible battery + battery charger + antenna +suitable belt clip in complete box packing. (2) one [1]no. spare battery compatible to the vhf set as per spec. no. rdso/spn/tc/107/2018. ver. 2.1. note 1:type of battery should be li-ion.] make & model: motorola xir p6600i battery ip67 or similar [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of sillicon rubber gasket overlay keypad , sillicon rubber gasket overlay display , rubber gromm? t , m3 plain washer , m2.5 plain washer , m3 x 6 mm ch hd , m2.5 x 16mm ch hd , m3x10 mm ch hd , m2.5 x 6 ch hd , lable (eald) , label (eh? ? ) , lable front panel , label for ald for ip
Tender For bid to ras supply of ceiling speakers , column array speakers , amplifier for ceiling speakers , amplifier for column array speakers , digital signal processor , boundary layer microphones , on off button for boundary layer microphones , switch box for boundary layer microphones , ceiling tile microphone array , main display , side display , annotation panel , cable manager for table , hdmi switcher , hdmi splitter , hdmi extender , usb tx multiformat switcher , usb rx multi format switcher , usb data matrix switch , ptz camera , speaker tracking camera , hdmi to usb capture card , voice tracking device , control system with touch controller , network switch , room scheduler , pdu with humidity and temperature sensor , ceiling mount document scanner , equipment rack , ups 10 kva ups with 60 min backup , ups 3 kva ups with 60 min back up , acoustic door with fitting laminate and door frame , chair , hot and cold ac 2 ton , room air purifier , bio metric door access control , auto fire suppression system for av rack , high quality wireless keyboard and mouse , led surface recessed mounted panel with luminous web , 12 channel signal dimmer controller , 12 channel controller , display keypad panel for workstations , network router for automation system , sitc supply installation testing and commissioning , acoustic wall paneling , acoustic false ceiling , wooden conference table , executive chair , acoustic carpet flooring , power supply for lighting control network , lighting control communicaiton gateway
Tender For supply of 1digital loadcell 30 ton , 2digital loadcell 10 ton , 3main card digital weight machine , 4 12 volt battery and battery charger 12 volt 2 ampere , 5display weight machine , 5charging main connector and keypad weight machine , 6digital weight indicator with weight transfer , 7fabrication of 10 ton fully electronic weighbridge