Get complete information related to latest Khadanja Work Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Khadanja Work Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Khadanja Work Tenders.
Tender For annual repair and maintenance of civil works during 2026-27 at coimbatore international airport. sh- annual maintenance contract for civil maintenance works in terminal technical block operational area and other buildings in the airside
Tender For supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35
Tender For providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : providing of repair and overhauling service - mobile communication terminal (hub); mobile communication terminal (hub); yes; buyer premises
Tender For repair replacement of internal unserviceable point wiring fitting fixture and connected accessories work in tarapore enclave, khetrapal enclave and abdul hamid under age em iv of ge(s) bathinda at bathinda mil stn - taking down carefully existing copper/aluminum point wiring (light,fan, socket or power) complete including fixture and fittings such as switches, bellpushes, ceiling roses, pendents, regulators, sockets, light fitting, call bells etc removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. to match existing complete all as specified and directed., m & l for point wiring with multi-stranded copper conductor, single core, pvc insulated and unsheathed cable, including pvc insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, gi terminal boxes, modular frame & cover plate (suitable for modular switch/sockets) comprising the following: -, one light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified., one socket outlet three pin, 6 amp, on the same board, with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, all as specified, one socket outlet three pin, 6 amp, independent, with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified., one bell/buzzer point controlled by one push button with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified, one light point controlled by two way switch. with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified., one socket outlet three pin, 5/15 amp, independent, with 2.5 sq. mm (nominal area) cable & 2.5 sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified., one light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic pvc medium duty concealed conduit all as specified., one socket outlet three pin, 6 amp, on the same board, with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, all as specified., one socket outlet three pin, 6 amp, independent, with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic pvc medium duty concealed conduit all as specified., one socket outlet three pin, 5/15 amp, independent, with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic pvc medium duty concealed conduit all as specified., one bell/buzzer point controlled by one push button with 1.5 sq. mm (nominal area) cable & 1.5 sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic pvc heavy duty concealed conduit all as specified., m & l for inverter wiring with multi-stranded copper conductor, single core, pvc insulated and unsheathed cable,one light point /one 5 amp socket point only.including drawn though pvc conduct all as specified and as directed., s&f switch modular type single pole, one way, 6 amp, one module, complete all as specified., s&f switch modular type single pole one way, 16 amp, one module, complete all as spe
Tender For tender for at zone no. 1a:maintenance and repair of staff quarters, service building, roads, drains and railway track : o.t. para including railway hospital, children park, rpf 'c' company, yard office, manihari terminal, yard fob, mangal bazar rob, sse(w)/w office, amm store, electrical sub station, kosi pump station etc. at katihar and all assets between katihar-teznarayanpur section, (km 0.00 to km 34.73) under sse/w/w/kir from 01.07.2026 and upto p.e 30.06.2028.
Tender For construction of khadanjawork at budha minor from km. 0.000 to 2.560 falling under the jurisdiction of irrigation construction division-5, jhansi at district jhansi.