Get complete information related to latest Knife Gate Valve Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Knife Gate Valve Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Knife Gate Valve Tenders.
Tender For supply of knifegatevalve ext dn250 or 10inch asme 150 metric pn20 unidirectional,body of ext 250nb with oipl standard powder coating and ansi 150 metric drilling and m24 flange fasteners,gate of ext 250nb ss304 and hcp 350bhn,nihard deflection cone 500bhn of ext 250nb,aluminium gland follower of ext 250nb,yoke of ext 250nb carbon steel powder coated,repair kit of 250nb,protection guard of ext 250nb carbon steel powder coated,knifegatevalve ext dn200 or 8inch asme 150 metric pn20 unidirectional,body of ext 200nb with oipl standard powder coating and ansi 150 metric drilling,gate of ext 200nb ss304 and hcp 350bhn,nihard deflection cone 500bhn of ext 200nb,aluminium gland follower of ext 200nb,yoke of ext 200nb carbon steel powder coated,repair kit of 200nb,protection guard of ext 200nb carbon steel powder coated
Tender For supply of safety valve spare : : - soot blower safety v/v 1 1/2 2 1/2, disc-soot blwr.safety v/v 1 1/2 x2 1/2, spindle for soot blower safety valve, adj. ring (upper) du no-004, adj.ring lower for sootblower safety v/v, spring assy. (0.27/cr), spring adj.nut/lock nut, disc.(cap 164.3t/hr), disc.(cap 138 t/hr), disc-7003 (1786wb/wd), disc for erv pilot valve 1538vx 10w, spring for erv pilot valve, spring for erv(main valve), seat bushing - erv pilot v/v 1538vx 10w, spindle or sb sv 1811 hc 6x20(7800), disc for shsv 1739wd
Tender For procurement of spares for il-78 aircraft - 63 unit control heating, electronic altimeter, arm 62t self contained servo unit rudder installation, relay box 66, relay box 024, left pilot additional speaker, fire extinguisher, kursmp.70 control panel, csd turbine, actuator, fixture, control unit, tape transport mech block, tank unit, pump booster(v), bulb - temperature (v), semi automatic parachute release unit, v trailing edge inner wing (l h), te vane inner wing flap rh sec 2, outer wing flap rh, pipe exhaust, shutter, fuel oil heat exchanger, auto start control, receiverbsi-3k-7, sweep unit, power unit, input information, receiver(av2.026.004.2.03 sp), unit, valve eletro hydraulic, low frequency unit, monitor auto pilot (v), oxygen mask, gear distributive, device(yam2.087.067-01), pannel, switch - power failure, memory block, magnetic recorder, rectifier unit, pcb,y-5, pcb,y-6, differential switch (pressure), sensor
Tender For work for supply of electrical spare parts for various maintenance under jurisdiction of phed city division ii - udaipur - mcb of breaking capacity not less than 10 ka isi marked is 8828 (1996) conforming to iec 60898 hpl/ indo asian , single pole mcb 6 to 32 amp. , double pole mcb 6 to 32 amp. , triple pole mcb 6 to 32 amp. , triple pole mcb 40 amp , triple pole mcb 63 amp , triple pole and neutral mcb 6 to 32 amp. , triple pole and neutral mcb 40 amp. , triple pole and neutral mcb 63 amp , four pole mcb 25 amp , four pole mcb 32 amp , four pole mcb 40 amp , four pole mcb 63 amp , mccb 16 ka 100 amp 4 pole hpl/ indo asian , mccb 25 ka 200 amp. 4 pole hpl/ indo asian , enclosure for mcb , 4 pole enclosure for mcb , 63 amp tpn din type sdf w/o fuse enclosure , 100 amp tpn din type sdf w/o fuse enclosure , 200 amp tpn din type sdf w/o fuse enclosure , enclosure for mccb , 4 pole mccb hpl / indo asian for tabi , current transformer 10/5 ratio, sv1a class 1 accuracy , current transformer 75/5 ratio sva1 , class 1 accuracy , current transformer 105/5 ratio, sva1 class 1 accuracy , selector switch for volt meter ( 4 position ) as required , ci linked selector switch of 10 a for ampere meter ( 4 position ) , 240/220v , led ( 22.5 mm dia) pilot lamp , red / yellow / green colour , blue colour , heavy duty 230/440 volt power contactor confirming to is 13947-4-1/iec : 947-4-1 having provision of mechanical inter locking din rail mounting type as required , 3 pole ac 3 rating contactor , 4 pole ac 1rating contactor , push button actuator and integral contact block of 22.5 mm dia , abb over loaded relay , abb contactor complete , magnet coil abb , time ctrl. electronic relay on delay timer 0 to 30 sec. abb , "tp&n 415 ac 23 a front handle operated switch disconnector fuse unit, cubical type as required without hbc fuse as required" , 240/415 porcelain kit kat fuse ( hbc type ) as required , hbc links fuse of 80 ka breaking capacity confirming to is : 13703 as required , capacitor , hrc fuse isi marked din type , hrc fuse base isi marked , copper lugs heavy duty (crimping type ) , ampere meter round 4 size , voltmeter round 4 size 0- 500 volt , armored aluminium cable isi marked , ct operated square ampere meter isi marked 96 mm 0 to 100 amp , ct operated square volt meter isi marked 96 mm 0 to 600 amp. , pvc insulated tape inch size , single phase preventor mini gelco , ambari rope 1 size , tyton rubber gasket , pvc copper wire , ci foot valve 5 , ci foot valve 6 , led bulb