Get complete information related to latest Lab Shaker Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lab Shaker Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lab Shaker Tenders.
Tender For tender for supply of handtools - feeler gauge length - 100 mm 0.05 -1.00 mm 13 leaves , model 184 - 305s of mitutoyo or equivalent p/n 157697108 , click torque wrench 20-100nm , 1/2 inch square drive , scale graduations-1nm accuracy +/-3% model a 2833 of tohnichi or equivalent size 157692151 , torque wrench 20-120 nm with hiper reversible ratchet torque range 20-120 nm +/- 2% drive 12.5 mm (1/2 inch) square drive length 435 mm. graduation 1 nm feedback click sound make/model abc-hazet 6121-1ct or equivalent dim. 2/12 kgm size 157697123 , direct reading torque wrenches torque range 5-25 nm drive (3/8 inch) square drive tightening both right & left hand accuracy +/- 4% length 253 mm. model beta 592/3 or equivalent dim. 0.5-2.5 kgm size 157697137 , dynamometer (digital weigher) 0-200 kg accuracy of +/- 0.5% of rated capacity. units of measuremenmt kg/dan/lb display(min) 0.5 kg resolution 0.5 kg anchor points dia 16mm protection ip 40 model handifor or equivalent dim. 0-200 kg , adjustable torque wrench interchangeable head , 100-850 nm model kanon n850 lck or equivalent size item 3 of pn 437601015
Tender For supply of spirometer with mip and mep testing facility,digital bmi machine,sitting height table,anthropometery kit item list attached in specifications,arm span measurement apparatus,multi frequency body composition analyzer,ecg machine,handgrip dynamometer,back dynamometer,sit and reach box,blood pressure monitor digital,portable lactate analzer with 200 strips,pulse oximeter,field test accessories kit as per specifications,automated external defibrillator,smart electronic stethoscope
Tender For corrigendum : tender for supply of engine raw emission measurement system , installation and commissioning of rem , third year camc of rem , fourth year camc of rem , fifth year camc of rem , ammonia mutlicomponent measurement system , installation and commissioning of ammonia system , third year camc of ammonia system , fourth year camc of ammonia system , fifth year camc of ammonia system , pn counter , installation and commissioning of pn counter , third year camc of pn counter , fourth year camc of pn counter , fifth year camc of pn counter , high speed engine dynamometer , installation and commissioning of dyno , third year camc of dyno , fourth year camc of dyno , fifth year camc of dyno
Tender For corrigendum : supply of dynamometer load range 0 4 kg , calibration of dynamometer load range 0 5 kg , calibration of dynamometer load range 5 15 kg , calibration of dynamometer load range 15 55 kg , calibration of dynamometer load range 0 500 kg , calibration of dynamometer load range 0 200 kg , calibration of dynamometer load range 0 50 kg , calibration of dynamometer load range 0 150 kg , calibration of dynamometer load range 0 5000 gram , calibration of dynamometer load range 0 80 kg , calibration of dynamometer load range 0 2 ton , calibration of dynamometer load range 0 5 ton , calibration of dynamometer load range 0 300 lbs , calibration of dynamometer load range 0 10 ton , calibration of aircraft weighing kit load range 5 ton , calibration of aircraft weighing kit load range 10 ton , calibration of universal testing machine load range 0 500 kg , calibration of universal testing machine load range 0 1000 kg , calibration of universal testing machine load range 0 3 ton , calibration of universal testing machine load range 0 5 ton , calibration of universal testing machine load range 0 10 ton , calibration of universal testing machine load range 0 20 ton , calibration of universal testing machine load range 0 50 ton , calibration of master dynamometer load range 0 1 kn , calibration of master dynamometer load range 0 5 kn , calibration of master dynamometer load range 0 10 kn , calibration of master dynamometer load range 0 50 kn , calibration of master dynamometer load range 0 100 kn , calibration of standardizing box load range 0 200 kn , calibration of traction power tester load range 0 500 kn , calibration of load cell load range 0 25 kn , calibration of new dynamometer load range 0 5 ton , calibration of new dynamometer load range 0 25 ton , calibration of dynamometer load range 0 5000 gm , calibration of traction power testerload range 0 500 kn