Tender For corrigendum : provision of electrical equipment against ber equipment held on charge of ge i cg goa - taking down existing industrial socket, indoor/outdoor unit of split type acs of any capacity and size with voltage stabiliser etc. contractor will carefully remove the aforesaid equipment from site and deposit to mes store under age e/m goa complete all as specified and directed., taking down old aluminium/copper sub main wiring of any type and capacity incl. all accessories and all as directed. note : (i) old dismantled wiring and accessories will be contractors property and credit will be charged against schedule of credit., supply and fix split air conditioner inverter type unit wall mounted, high wall split units indoor & outdoor complete with provision of cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with bee 5 star rated and capacity 1.5 tr, single phase 240 volts, 50 hz complete all as directed by engr-in-charge. make: voltas, lg, bluestar, hitachi., supply and fix split air conditioner inverter type unit wall mounted, high wall split units indoor & outdoor complete with provision of cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with bee 5 star rated and capacity 2.0 tr, single phase 240 volts, 50 hz complete all as directed by engr-in-charge. make : voltas, lg, bluestar, hitachi., supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of 2.5% and of capacity 4 kva. make: v-guard, luminious, microtek., supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of 2.5% and of capacity 5 kva. make: v-guard, luminious, microtek., m & l for sub main wiring with two runs of single core 4 sqmm frls copper conductor pvc insulated unsheathed cable as per is 694-1990 (third revision) drawn through & incl casing and caping of suitable size with all accessories such as tees, elbows,couplings, junction boxes etc, as required fixed on wall along with one run of 4 sqmm single core frls insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. note : (i) two runs of phase & neutral wire, one run of earth continuity conductor cable and one run of casing & capping will be measured as one unit for payment purpose.(ii) the wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads., s & f single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole c series mcb 20 amps complete all as specified., supply and fix refrigerators not less than 310 litres, electric driven (single phase), bee 5 star rate with the following features i.e frost free, double door, auto defrost to stop ice builtup, adjustable temperature controller, double door with separate compartment for freezer inverter type compressor with energy efficiency of 5 star rating, tuffened glass shelf complete with an overall product warranty of one year & 10 year on compressor complete including all as specified and directed. note - old removed item shall be deposited in mes store., supply and fix electric water heater, storage type fibre body with copper heating element upto 2 kw capacity 25 litre, bee 5 star rated complete with all accessories such as safety valve, thermostate, nrv, pvc connection pipe and plug top 15 amps etc. including taking out unserviceable one complete all as specified and directed. note - old removed geyser shall be deposited in mes store. make orient cat
Tender For bid to ras supply of ceiling speakers , column array speakers , amplifier for ceiling speakers , amplifier for column array speakers , digital signal processor , boundary layer microphones , on off button for boundary layer microphones , switch box for boundary layer microphones , ceiling tile microphone array , main display , side display , annotation panel , cable manager for table , hdmi switcher , hdmi splitter , hdmi extender , usb tx multiformat switcher , usb rx multi format switcher , usb data matrix switch , ptz camera , speaker tracking camera , hdmi to usb capture card , voice tracking device , control system with touch controller , network switch , room scheduler , pdu with humidity and temperature sensor , ceiling mount document scanner , equipment rack , ups 10 kva ups with 60 min backup , ups 3 kva ups with 60 min back up , acoustic door with fitting laminate and door frame , chair , hot and cold ac 2 ton , room air purifier , bio metric door access control , auto fire suppression system for av rack , high quality wireless keyboard and mouse , led surface recessed mounted panel with luminous web , 12 channel signal dimmer controller , 12 channel controller , display keypad panel for workstations , network router for automation system , sitc supply installation testing and commissioning , acoustic wall paneling , acoustic false ceiling , wooden conference table , executive chair , acoustic carpet flooring , power supply for lighting control network , lighting control communicaiton gateway
Tender For corrigendum : district wise detail project report (dpr) for estimating, rate analysis, quantity calculation of model drawing for construction of science laboratories along with innovative laboratoryequipments (ai supported) & introduction of smart class rooms in hs level schools (same premises) and additional girls toilet & boundary wall in secondary level schools (same premises) including binding and cost of labour charges in complete.
Tender For corrigendum : supply, installation, testing, commissioning and trail run of machinery and equipment on turnkey basis for godavari coconut association - schedule a, effluent treatment plant, rainwater harvesting setup, water processing setup including ro water tank plant 8000 lph along with sump 50000 kl, schedule b, rooftop solar setup 650 kva, schedule c, electrical installation & equipment s including 700 kva transformer, schedule d, coconut primary processing:storage containers attached with electric chain hoist system and coconut dehusking & deshelling setup, schedule e, pairing system setup with conveyor, coconut oil extraction setup with provision for testa & virgin oil, schedule f, coconut meat processing and milk extraction setup, schedule g, quality control (qc & qa lab) setup, industrial air conditioning, dg set 320 kva, schedule h, training skill development setup, schedule i, material handling equipment s
Tender For repairs & service of laboratoryequipments in various items at central lab- bod incubator, hot air oven , orbital shaking , incubator (cooling), , micro controller based digital ph meter, , -86 ultra , low temperature freezer , , refrigerated centrifuge , , refrigerated centrifuge , , seed germinator , hplc
Tender For corrigendum : tender for supply installation and commissioning of quantum laboratoryequipments for tamil nadu technology itnt hub - tender for supply, installation and commissioning of quantum laboratory equipment’s for tamil nadu technology (itnt) hub
Tender For water quality monitoring and surveillance programme in tehsil sadar district bilaspur (sh providing of laboratoryequipments and chemicals in jal shakti divisional lab at bilaspur).
Tender For corrigendum : supply installation testing and commissioning of pump unit and other electro-mechanical equipments at laripora pahalgam - supply, installation, testing and commissioning of submersible type pump sets with motors and allied mechanical and electrical components/ items as per manufacturer s recommendations and guide lines, and as per the scope of the work at site. the equipment supplied conform to latest is- standards and codes with fail safe circuits/ devices for(i) over loading (ii) under loading (iii) clogging (iv) shut off (v) low liquid level (vi) single phase prevention devices (vii) over heating etc. the pumping units shall have following technical specifications: pumps:type of pump :non clog centrifugal volute type sewage submersiblepumpscapacity= 28.4lpshead = 17.5 metres or abovesolid handling capacity: 20mm (minimum) quality of water: sewage water to be handled meterial of construction:pump casing : cast ironimpeller : stainless steelpump shaft : stainless steelmotor body : cast ironsealing : dual mech. seal...contd.. as per annexure-a, providing/supplying and fitting of 100 mm m.s flanged delivery main to be connected with existing rising main at site. the job includes providing and welding of m.s flanges 12 mm thickness. the flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. the cost on account of supply/ fabrication of bends and providing/ fitting of flanges is included in the job. (complete job)., providing and fitting of 100 mm dia ductile iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves as per is14846 for regulating the water supply outside the pumping units p.n rating 1.0.the job includes providing and fitting of 02 nos. m.s flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement (complete job)., providing and fitting of 100 mm dia ductile iron double flanged, slanted seat swing check valve( nrv) as per is 5312 p.n rating 1.0.the job includes providing and fitting of 02 nos. m.s flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement (complete job)., gantry over sump :- fabrication, providing, fitting of ms gantry over sump with 02 nos. vertical columns. the gantry fabricated out of ismb-100, 3.25 mts long placed face to face. 300x300mm ms plates 12mm thick fitted on top and bottom side of column .bottom plate welded to the reinforcement of the sump and grouted in 1mx1mx1m pcc 1:1.5:3 mix. ismb-100,3mts long is to be placed and welded to the top plate of the columns .the job also includes providing and fitting of 2-tonne capacity chain pulley block with monorail along with hoisting chain (complete job)., providing and fitting of 50 mm23.5 core ,al pvc insulated cable, armouredfor internal connectionscrimping, taping etc. note:- the cable terminal ends for connection to switchgear at various requisite points shall be al. thimbles and of appropriate size and connected by hydraulic crimp tool only (complete job)., providing and fitting of 4-core 16 mm2 flat /circular submersible copper cable conforming to is: 694 (part 1st) 1964 & is: 694 (part 2nd) - 1964 for submersible pumping unit and other electrical equipment s. the cable connections terminal shall be fitted with copper thimbles of required size (complete job)., fabrication, providing and fitting of main electric control panel of appropriate size fabricated out of 14 swg sheet having required openings/vents and protection class : ip-55 & fitted with accessories as under: a) bus bar chamber: 160 amperes(tpn) b) main circuit breaker (incomer mccb) qty:- = 01 nocurrent rating = 160 amp. c) change over switch:qty. = 01 no.rating = 160 ampere....contd... as per annexure-a., electrification. providing/fitting of lighting and fan