Tender For procurement and installation of ece lab equipments - procurement and installation of ece lab equipments, single output variable dc rpsu single output regulated power supply- input voltage: 230v/50hzac- output voltage: (0 30v)dc- output current: (0 2a)dc- protection circuit: over voltage and over current protection, short-circuit protection- high efficiency: greater than 85%- low ripple and noise: less than 50 mv, dual output variable dc rpsudual output regulated power supply- input voltage: 230v/50hzac- output voltage: (0 30v)dc- output current: (0 2a)dc- protection circuit: over voltage and over current protection, short-circuit protection- high efficiency: greater than 85%- low ripple and noise: less than 50 mv, function generatorfrequency range: 0.1 hz to 2 mhz.display: 4 to 6 digit led displayoutput waveforms: sine, triangle, square, pulse, ramp.amplitude: 0 20 vp-p.rise time: 100 ns.distortion: 1% (within acceptable range of frequencies).power supply: ac 220 v 10%, 50-60 hzoutput amplifier protection: protected against short circuit and 15v overload, digital storage oscilloscopebandwidth: 50 - 100 mhz.sampling rate: 1gs/s.channels: 2 (minimum)power supply: 100v 240v ac, 50-60 hzautomatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc.,horizontal scale: 5 ns/div 100 ns/div or equivalentvertical resolution: 8 bits (2 channels simultaneously)vertical sensitivity: 1 mv/div 10 v/div (at input)waveform math: +, -, x , , invert, fft etc.,waveform storage: 16 waveforms or equivalentcommunication interface: usb host, usb interface.7-inch color display or equivalentbasic trigger functions, digital vo;tmeterdc voltmeter digital 3 digit display (0-100 v), 0.5 % accuracy (class 0.5 equivalent) (2000), digital ammeterdc ammeter digital 3 digit display (0-2 a), 0.5 % accuracy (class 0.5 equivalent) (1500), eliminator transformer (stepdown)input - 220v - 240v ac, 50 hz, output-2v to 12v dc, 0-2 a ripple: 5mv, embedded lpc 2148 kit cpu - lpc2148, core - 16/32 bit arm7dmi-s speed - max 60 mhz, flash - 512kb, ram (on-chip) - 40kb, 46 general purpose i/opins, usb2.0 one 10bit a/d converter with 14 analog inputs, one 10bit d/a converter, six pwm &watchdog two uarts (16c550), two i2c (400kb/s), two spi s eight bit digital output, eight bit digital input, 16 x 2 characters lcd and 4x4 matrixkeypad one potentiometer for giving analog input, relay & buzzer interface i2c devices: rtc, eeprom and seven segment display, on board stepper motordriver lm35 temperature sensor, one rs 232 lines are terminated at 9 pin d type connectorand usb interface board has inbuilt power supply and mounted in sturdy cabinet accessories usb cable with utility software to download programs from pc to target board example programs in embedded c and assembly with documentation (soft copy) power chord, user manual with cd/dvd, free demonstration after delivery, single phase induction motorsingle phase induction motor, 230v ac, 50hz supply.power rating 1 hp (0.75 kw).speed 1440 rpm.capacitor start/run type suitable for lab useloading setup portable ammeter and digital tactometer contact type, single phase autotransformerinput - single-phase, 230v/240v, 50 hz, 4a, ac output - 0 to 270vac, class "h" or class f insulation., lvdt trainer kitac mains power supply : 230v 10%, 50hzfixed regulated dc power supply : +5v, 12v /500matransducer : lvdtlvdt displacement : 20mm (40mm total)displacement scale : linear 20mmdisplacement display (mm) : red color 3 digit led displayexcitation frequency : 4khzexcitation voltage : ac variable 5v, strain guage trainer kitmetal foil strain gauge mounted on beam/cantileverstrain measurement under applied loadwheatstone bridge arrangementsignal conditioning and amplification circuitinstrumentation amplifiers, 3 digit display of strain / output voltagezero and gain adjustment controlsprovision for applying calibrated loadsregulated power supply, 230 v ac, 50 hztable-top tr
Tender For auction sale of scrap item of tube bunch of lp heater/gland coolers/exchanger,scrap power transformer 1600 kva, 6.6/0.433 kv,scrap 400 kv capacitor voltage transformer
Tender For estimate for supply, erection & commissioning of various electromechanical equipment like 5 no. 5 cs. vt pump, electric motors, starter panel and other allied material for flood protection works from the field area of village dang khurd & outfall at rd 65000-r of nigana feeder in lift w/s (m) division, bhiwani for the year 2026-27. - supply, erection & commissioning of 5 c/s axial/mix flow water lubricated vertical flood pumps of 5 cs. discharge at 1440 rpm at static head of approx 6.0 mtr. having adjustable height, including ms bend including flange welding, ss/ht nut & bolts etc complete in all respect as per site requirement with epoxy coating & as per approved specifications of the department, supply, erection & commissioning of solid shaft motor of capacity 30 hp, 1440 rpm, 3 phase, 380 volt+- 10%, with eficiency class ie2 (with 35 mtr compatible 3 phase submersible cu cable from motor to panel/starter) suitable for fitment with 5 cs. v.t axial/mix flow pump type vertical flange mounted as per approved specifications of the department., supply, erection & commissioning of fully automatic star delta starter of cap. 150 amp including all accessories as one incomer of mccb (150amp) with 1 no mcb for lighting load, contactor rating 120 amp, 90 amp, 70 amp with control transformer for control supply, outgoing indicator, having mpr & all types of protections i.e.uv/ov/ over current, phase imbalance/phase reversal protection, locked rotor, dry run etc, digital meters, push buttons, bus bars, capacitor bank, seperate relay for single phase protection etc. complete in all respect suitable for open fields operation of 1 no. motor of capacity of 30 hp with a stand of ms channel with canopy having suitable operating height above the kachha open fields as per approved specifications of the department. (suitable for voltage range 380 +- 10%,) panel should be outdoor type., supply, erection & commissioning of m.s delivery pipe 10" dia. made of ms plate both end flanged (equal to or less than 6 mtr length of pipe) as per approved specification & make. (including ss/ht nut & bolt, rubber packing & other fitment accessory required), supply, erection and commissioning of ms girder parallel flange section ismb 150 with primer and bituminous based paint inside & outside of length 4mtr (approx wt 60 kg per pc) as per approved make & conforming to is808:2021.
Tender For supply 220kv cvts and cts with standard accessories and fittings matching with existing cvt/ct foundations and height at stps, suratgarh - supply items:-, 220 kv capacitor voltage transformer as per technical specifications enclosed, 220 kv current transformer as per technical specifications enclosed
Tender For supply of equipment items - , "acidity test kit-ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications ", "3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided ", "linear variable differentialtransformer measurement trainerspecifications: input supply : 230 v ac, 50 hz type : linear variable differential transformer (lvdt) trainer kit lvdt stroke length : 25 mm led display provided digital voltmeter provided for output measurement potentiometer provided for calibration and adjustment signal conditioning circuit inbuilt zero adjustment and calibration facility provided test points provided for waveform/signal observation clearly labeled circuit diagram on front panel proper insulated terminals and safety sockets provided "
Tender For corrigendum : supply of miscellaneous electric items for coal handling plant, stps, suratgarh - photo electric switch, flush head 22.5 mm push button, red, flush head 22.5 mm push button, green, 22.5 mm emergency stop push button, lockable with key, din rail mountable on delay timer, 3-300 sec, 2 c/o, contact, control supply-240 vac,, din rail mountable off delay timer, 3-300 sec, 2 c/o, contact, control supply-240 vac, din rail mountable on delay timer, 5-100 sec, 2 c/o, contact, control supply-240 vac,, din rail mountable off delay timer, 5-100 sec, 2 c/o, contact, control supply-240 vac, 1 kva constant voltage transformer (cvt) with i/p, voltage-180-260v, o/p voltage-230v, frequency-50hz,, harmonic distortion-below 3% under full load conditions,, insulation-class a, dol starter for motor rating 5.5kw, 3ph, ac-3, voltage-, 415v, 50hz, dol starter for motor rating 11kw, 3ph, ac-3, voltage-, 415v, 50hz, dol starter for motor rating 22.5kw, 3ph, ac-3, voltage-, 415v, 50hz, stud type rectifier diode, hs15hrs100 or equivalent, stud type rectifier diode, hs15hr55 or equivalent, stud type rectifier diode, hs15hn55 or equivalent, stud type rectifier diode, s8br71 or equivalent, stud type thyristor, h55tb8 or equivalent, electrolytic capacitor, 1000 mfd, 400v dc, electrolytic capacitor, 2500 mfd, 400v dc, control transformer, 400va, copper winding, primary, voltage:0/360/380/415v, secondary, voltage1:0/24/28/30/32v(240va), secondary, voltage2:0/220/230v(160va), control transformer, 250va, copper winding, primary, voltage:0/210/220/230/400/440/460, secondary, voltage:0/24/110v, control transformer, 500va, copper winding, primary, voltage:0/360/380/415v/440v, secondary, voltage:0/110/230v, carbon brush of size(lxwxd):40x32x16 mm3, carbon brush of size(lxwxd):40x32x12.5 mm3, carbon brush of size(lxwxd):40x32x22 mm3, carbon brush of size(lxwxd):40x40x20 mm3, carbon brush of size(lxwxd):40x22x10 mm3
Tender For supply of equipment items - acidity test kit-ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications , 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , linear variable differentialtransformer measurement trainerspecifications: input supply : 230 v ac, 50 hz type : linear variable differential transformer (lvdt) trainer kit lvdt stroke length : 25 mm led display provided digital voltmeter provided for output measurement potentiometer provided for calibration and adjustment signal conditioning circuit inbuilt zero adjustment and calibration facility provided test points provided for waveform/signal observation clearly labeled circuit diagram on front panel proper insulated terminals and safety sockets provided