Get complete information related to latest Labyrinth Packing Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Labyrinth Packing Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Labyrinth Packing Tenders.
Tender For supply, delivery and installation of advanced testing mechanism, lab equipment for conducting daily quality of drinking water in tanuku municipality supply, delivery & installation of compact photometer pf-12plus make: mn, germany (or) any equivalent isi make model no: 919250 technical specifications: type: filter photometer with microprocessor control, self-test and auto-calibration light source: xenon lamp optical system: automatic filter wheel with 7 interference filters wave length: 345 nm / 436 nm / 470 nm / 540 nm / 585 nm / 620 nm / 690 nm plus 1 compartment for an additional filter, 860 nm led for ntu measurement wave length accuracy: ± 2 nm, bandwidth at half transmission: 10 nm?12 nm photometric range: ± 3 e photometric accuracy: ± 1 % long term stability: < 0.002 a/h measuring modes: more than 100 preprogrammed tests and special methods, absorbance, transmission, factor, standard, nephelometric turbidity measurement; 50 freely programmable methods pre programmed tests: nanocolor tube tests, visocolor eco tests and powder pillows turbidity measurement: nephelometric turbidity measurement at 860 nm (based on iso 7027), 1?1000 ntu cuvette slot: round tubes 16 mm od data memory: 1000 results, glp conform display : backlit graphic display, 128 x 64 pixel auto off: inactive or automatic shutdown after 5 min, 10 min, 15 min, 20 min, 60 min internal quality control: with nanocontrol nanocheck 2.0 operation: self-explanatory menu guidance, plastic foil keypad, test selection via parameter lists language: de / en / fr / es / it / nl / hu / pl / pt / cz / id / sl / tr / my operating range: 10?40 °c (50?104 °f), max. 80 % relative humidity (non-condensing) power supply: via usb power supply, standard or rechargeable batteries or accu-pack weight: 0.7 kg dimensions (l x w x h): 215 x 100 x 65 mm scope of delivery photometer, software dvd, manual, visocolor eco test instructions, 4 batteries, 4 empty test tubes, funnel, beaker, syringe, usb cable, calibration cuvette, cleaning cloth and certificate in rugged case hazardous material: no , supply, delivery & installation of mm42dp-ph,ec,tds portable multi-parameter water quality meter with ph, conductivity electrodes. includes: mm-42dp(main unit)+mm4-ph(1m) ph electrode+mm4-ec(1m) ec electrode make: dkk-toa corporation, japan. technical specifications : measuring method : ph : glass electrode method orp : platinum electrode method conductivity : ac bipolar method dissolved oxygen : optical type temperature : thermistor resistor display unit :custom lcd(with backlight) measurement items/ranges : ph : ph0.000 to ph14.000 mv (orp) : -2000 to 2000mv conductivity:0.1ms/m to 10s/m d0: 0.00-20.00mg/l or 0.0 to 200.0% electrical resistivity:0.1o.m to 10ko.m (converted from electric conductivity) salinity (nacl):conversion from electrical conductivity salinity (pss: practical salt):conversion from electrical conductivity total dissolved solids (tds):conversion from electrical conductivity temperature:0.0to100.0°c display range : ph : ph-2.000to ph16.000 mv (orp) : 0to99.99mg/l 0to999.9mg/l 0to9.999g/l 0to99.99g/l 0to999.9g/l (automatic/manual range switching) temperature :-5.0to110.0°c do:0.00-22.00mg/l or 0.0 to 220.0% display resolution : ph :0.01ph/0.001ph mv (orp) :1mv conductivity :0.05%fs electrical resistivity :0.05%fs, salt :0.01%(nacl)0.01psu(pss) total dissolved solids (tds) :0.01%fs temperature :0.1°c, repeatability (instrument body): ph :within ±0.006ph mv (orp) :±2mv, conductivity :±0.5%fs, do:when combined with 8mg/l ±0.1mg/l or 100%±1% electrical resistivity :±0.5%fs salt :±0.5%fs, total dissolved solids (tds) :±0.5%fs temperature :within ±0.2°c ph temperature compensation range: atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0? electrical conductivity temperature compensation range : atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0°c atc off (no temperature c
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to
Tender For supply of accessories for electrochemical alkaline cell e e - item 1 platinum plate electrode holder as per specification , item 2 carbon paper as per specification , item 3 carbon paper as per specification , item 4 carbon paper as per specification , item 5 carbon cloth as per specification , item 6 nickel foam as per specification , item 7 zinc foil as per specification , item 8 zinc foil as per specification , item 9 separator as per specification , item 10 zn air cell setup as per specification