Web Analytics Made Easy - StatCounter

Laser Tracker System Tenders

Get complete information related to latest Laser Tracker System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Laser Tracker System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Laser Tracker System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42097522 Due date: 08 Oct, 202508 Oct, 2025 NA
Tender For providers for equipment's- load measurement setup, speed measurement setup, temperature measurement setup, flow measurement setup, pressure measurement setup, torque measurement setup,strain measurement setup

Central Government/Public Sector

CTN :41766269 Due date: 07 Oct, 202507 Oct, 2025 NA
Tender For corrigendum : supply installation and commissioning of electrochemical workstation setup for the measurement of integrated energy cells

Central Government/Public Sector

CTN :42027108 Due date: 06 Oct, 202506 Oct, 2025 NA
Tender For supply of impact testing machine , crushing value testing machine , los angeles abrasion testing machine , flakiness index test gauges , elongation index test gauges , aggregate water absorption test set up , pycnometer as per requirement , is sieves for coarse aggregate gi sieves dia 300 mm , is sieves for fine aggregate brass sieves dia 200 mm , automatic sieve shaker 18 inch , bitumen extractor machine , vicat apparatus with deskpot , le-chatlier flasks , le-chatlier moulds , burette as per requirement , measuring cylinders , trowel small , trowel big , trays , sampling scoop , steel buckets as per requirement , cement cube moulds , automatic manual mortar mixer as per requirement , vibrating machine as per requirement , curing tank with controlled temperature , atterberg limits set-up liquid limit , atterberg limits set-up plastic limit , shrinkage limit apparatus with mercury , hydrometer analysis set-up range , free swell index apparatus , proctor testing equipment , core cutter test set up for in-situ density min. 6 mould with 01 hammer , sand replacement test set up for in-situ density , moisture container for omc by conventional method , hot air oven digital , physical balance electronic , rapid moisture meter , thermometer for measurement of room temperature , thermometer for measurement of temperature of bitumen, concrete , digital compression testing machine 2000 kn capacity semi automatic , digital compression testing machine 500 kn capacity , measuring tape 3m , measuring tape 10m , measuring tape 30m , measuring tape 50m , concrete cube moulds , concrete mixer 0.5 cum capacity electrically operated , concrete workability test by compaction factor test , ph meter , paint thickness meter elcometer ultrasonic digital , dial callipers , vernier callipers , digital micrometre , outside micrometres , depth gauge , density pot , density basket , slump test apparatus , electric platform balance 150 kg , electric pan balance 10 kg 1gm , precision balance 600 gm 0.1 gm , measuring flask , upv ultrasonic pulse velocity tester , rebound hammer , core falltering machine , flexural test appratus for beam , core cutting setup for conceret , rebar detector to locate reinforcement before core cutting

CTN :42024644 Due date: 17 Oct, 202517 Oct, 2025 NA
Tender For purchase of broadband dielectric spectroscopy measurement setup

State Government

CTN :41676459 Due date: 07 Oct, 202507 Oct, 2025 NA
Tender For corrigendum : empanelment of agencies for supply of different laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20

CTN :41943214 Due date: 16 Oct, 202516 Oct, 2025 NA
Tender For antenna alignment using laser tracker system

CTN :41811649 Due date: 03 Oct, 202503 Oct, 2025 NA
Tender For supply of physics lab equipment : : - electrostatics lab trainer , magnetism lab trainer kit , optics bench trainer kit , divergence of laser trainer kit , moment of inertia setup with lamp and scale , youngmodulus setup , boyle demonstrator trainer kit , acceleration measurement setup , joule constant measurement setup
 Loading, Please wait...

Connect us via What's Up