Web Analytics Made Easy - StatCounter

Laser Amplifier Machine Tenders

Get complete information related to latest Laser Amplifier Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Laser Amplifier Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Laser Amplifier Machine Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :45702242 Due date: 07 Jul, 202607 Jul, 2026 17.03 Lacs
Tender For regular operation and maintenance of street lights (with material) at all industrial areas under riico ranpur kota(for 2 years) - regular operation and maintenance of high mast light in ranpur , kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register shall be maintained at riico/association office and complaint lodged must be attended by contractor within 24 hours. the person deputed by contractor shall attend the riico/association office daily and comply the instructions and attend complaints regularly. iii contractor will have to employ trained and qualified electricians for the work. iv corporation shall not be responsible for any kind of accident during execution of work. v contractor will be responsible for safety and security of fixtures and all concerned materials. vi contractor will be responsible for arrangement of all t&p required for the work vii cost of all labour and material like lamp / balllast wire etc. will be born by contractor. all material required for the work shall not be below the category-ii of concerned bsr item. contractor has to repair and maintenance of fixture with material in all cases like short circuit, phase to phase of jvvnl line etc. viii no extra payment will be made for fixing/removal of extra/existing fixture in the industrial area. ix contractor will be responsible for timely collection and deposition of electric bills of areas in each month. in case of delay in payment and jvvnl impose surcharge for delay payment the same will be recovered from the running bill fo the contractor. payment of electricity bill will be made by riico. x contractor will be responsible for rebate of timer provided by jvvnl. hence contractor will maintain the on/off system by timer properly. in case no rebate is provided by jvvnl due to failure of timer then rebate will be deducted from contractor payment. xi contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. in case of any theft is found suitable penalty will be imposed on the contractor. xii contractor will maintain cubical panel board and assessories fitted in it. in case of any fault repair/replace of material will be done by the contractor at his own cost. no extra payment will be made on behalf of material. xiii contractor has to keep ready total fixtures. in case of fault of fixture a penalty of rs.100/- per fixture per day will be imposed on the contractor., regular operation and maintenance of street light fixtures hpsv/ hpmv (70w/150w) in ranpur, kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register sh

Corporations And Associations And Others

CTN :45723486 Due date: 08 Jul, 202608 Jul, 2026 5.01 Lacs
Tender For procurement of material and hiring of labour for day to day maintenance of various electrical installations in municipal parks and buildings in ward 140 inderpuri under kbz - supply of 1.5 sq. mm isi marked, frls pvc insulated,single core copper conductor cable as required., supply of 4.0 sq. mm isi marked, fr pvc insulated, single core copper conductor cable as required., supply of 63 amps., 2 pole isolator as required., supply of 6 a, to 32 a, ratings, dp mcb, "c" curve, 10 ka breaking capacity as required., supply of 6a to 32 a ratings, sp mcb, "c" curve, 10 ka breaking capacity as required., supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd., supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:- 2x 6 sqmm, supply of xlpe insulated pvc sheathed al. conductor armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*10 sqmm, supplying, lowering, testing and commissioning of vertical type, multistage, totally enclosed water filled deep well submersible pumping set complete i/c connection etc. as reqd. (c) three phase 5.0 hp having discharge of 300 lpm approx. at 39 m head., providing following labour for day to day maintenance of ward i/c required t&p etc. in one shift in a day on all working days (required maintenance material will be provided by department) as required as per terms & condition of the department (excluding parts) complete as required. 1. skilled labour", providing following labour for day to day maintenance of ward i/c required t&p etc. in one shift in a day on all working days (required maintenance material will be provided by department) as required as per terms & condition of the department (excluding parts) complete as required. 1. un-skilled labour", supply of led street light fixture, powder coated pressure die cast aluminium body (system lumen efficacy 120 135 lm/watt) of following body materials. - 45 watt

CTN :45703686 Due date: 11 Jul, 202611 Jul, 2026 3.00 Lacs
Tender For supply of lighting material b b - s t bulb 100 watt 220 v , m v lamp 250 watt , m v lamp 125 watt , m v choke 400w bajaj make , 250 w hpsv tubular lamp 200 250v bajaj , 400 w hpsv tubular lamp 200 250v bajaj , 250 w hpmv tlamp 200 250v bajaj , h p s v choke 250 watt , h p s v choke 400 watt , led flood light 50 watt warm white make jaguar philips , led flood light 50 watt white make jaguar philips , mcb box for dp mcb , mcb box for tp mcb , double pole mcb 32 amp , led flood light 200 watt white make jaguar philips , led flood light 200 watt warm white make jaguar philips , led warm white bulb 15 watt , p t s t led warm white bulb 15 watt , s t warm white led bulb 12 watt , p t bulb 100 watt , mcb 63 amp triple pole siemens make , led flood light 150watt warm white make jaguar philips , led flood light 150 watt white make jaguar philips , s t bulb holder 400 watt , led flood light 100 watt warm white make jaguar philips , led flood light 100 watt white make jaguar philips , s t holder 100 w , h p s v choke 125 watt , mv choke 250 watt , led street light 50 watt warm white make jaguar philips , led street light 50 watt white make jaguar philips , ignitor for sodium lamp 70 400 watt in steel body , mcb 16 amp single pole siemens make , mcb 16 amp double pole siemens make , elcb 63 amp double pole siemens make , led hanging light worm white 300w , led hanging light white 300w , led tube light 24 watt havells syska philips

CTN :45689064 Due date: 10 Jul, 202610 Jul, 2026 2.16 Lacs
Tender For supply of pvc copper wire , led flood light , led flood light , pvc all wire , aluminium wire , pvc copper wire , pvc all armoured cable , copper wire imm , pvc wire al. conductor , led street light , pvc cable , pvc armoured cable , polycab make armourd cable , aluminium wire , hpsv ignitor , 9 volt battery cell hi watt make

CTN :45632952 Due date: 06 Jul, 202606 Jul, 2026 1.00 Lacs
Tender For supply of hpsv lamp 250w bajaj crompton havells , hpsv lamp 400 w bajaj crompton havells , hspv chok 250 w bajaj crompton havells , hpsv chok 400 w bajaj crompton havells , sc screw type bulb 500w bajaj crompton havells , sc bulb 300 w bajaj crompton havells , pt bulb 24 v 100w bajaj crompton havells , pt bulb 60 w bajaj crompton havells , pt bulb 100 w bajaj crompton havells , sc bulb 60 w bajaj crompton havells , sc bulb 100 w bajaj crompton havells , industrial street light fitting 1x40w complete bajaj crompton havells , industrial street light fitting 2x40w complete bajaj crompton havells , tubelight fitting complete. bajaj crompton havells , sv lamp 250w complete fitting bajaj crompton havells , mv lamp 250 w complete lamp bajaj crompton havells , halogen lamp 500 w with fitting bajaj crompton havells , condensor for 400 w sv mv lamp bajaj crompton havells , condensor for 250 w sv mv lamp bajaj crompton havells , led 09 watt bajaj crompton havells , led 012 watt bajaj crompton havells , pt pin type holder bajaj crompton havells

Central Government/Public Sector

CTN :44222617 Due date: 24 Jun, 202624 Jun, 2026 NA
Tender For bid to ras supply of 1 . 82334000670 150 watt warm white led flood light , 2 . 82334000410 led street ltg fitting 120w , 3 . 82334000700 150w led street light with programmable driver. , 4 . 82334100010 warm white led equ. to 70w hpsv wellglass , 5 . 82334000660 luminaires 150 watt led flood light luminaires , 6 . 82334000530 led well glass ftg 40w , 7 . 82334145230 led street light fitting 90w , 8 . 82334000680 250 watt warm white led flood light luminaires , 9 . 82334000640 250 watt led flood light luminaires , 10 . 82334000500 led tube light 20w 4ft , 11 . 82334002010 led tube light fitting 18w by 20w , 12 . 82350015020 led luminaire equv. to 2x4ft t8 tubelight , 13 . 82334145230 350 watt warm white led flood light luminary with programmable dimmable driver

CTN :45593146 Due date: 02 Jul, 202602 Jul, 2026 80.0 Thousand
Tender For supply of pt bulb , st bulb , f tube chowk , led tube light , led flood light , led street light , hpmv lamp , hpsv lamp , hpsv chowk 250w , hpsv bulb 250w , hpsv bulb 150w , hpsv chowk 150w , electronic ignitor

Corporations And Associations And Others

CTN :45523190 Due date: 19 Jun, 202619 Jun, 2026 4.76 Lacs
Tender For provision of new led street lights with allied accessories on existing poles at various dark spots in saidulajab ward no 160 under south zone - led street light fixture, powder coated pressure die cast aluminium body (system lumen efficacy >135 lm/watt). supplying, installation, testing & commissioning of street light led fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage: 140-270 volt ac, frequency 50/60 hz, operating temp range -5 0c to 50 0c, internal surge protection of 5 kv l,n,e as per iec 61000-4-5, driver efficiency >85%,thd 10% as per iec 61000-3-2, p. f. 0.95, ip-66,ik-10, cri >70, under voltage and over voltage protection, emi-emc as per cispr-15, lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led,driver & electrical circuitary) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report, cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin), sdcm(standard deviation color matching)5, maximum power consumption should not more than the specified rating and fixture shallbe of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductorsingle core cable and earthing etc. as required withminimum 5 year oem warranty. system lumen efficacy >135 lm/watt output . lm79 & lm80 testreport and all testing required for led fixturesas per bis shall be submitted.. shape size and cct shall be as approved by engineer-in-charge asper requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90 c). 45 watt , supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3 x 1.5 sq. mm, supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*4 sqmm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. upto 35 sq. mm

Corporations And Associations And Others

CTN :45523194 Due date: 19 Jun, 202619 Jun, 2026 4.67 Lacs
Tender For provision of led light fittings with accessories at various locations in ward no. 167 khanpur, under south zone. - supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3 x 1.5 sq. mm, supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd., supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*4 sqmm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. upto 35 sq. mm, led street light fixture, powder coated pressure die cast aluminum body (system lumen efficacy 135 lm/watt) supplying, installation, testing & commissioning of street light led fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage: 140-270 volt ac, freq 50/60 hz, operating temp range -5 deg centigrade to 50 deg centigrade, internal surge protection of 5 kv l,n,e as per iec 61000-45, driver efficiency >85%,thd 10% as per iec 61000-3-2 , p. f. 0.95, ip66,ik-10, cri 70 , under voltage and over voltage protection,emi-emc as per cispr-15, lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led,driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report , cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin) , sdcm(standard deviation color matching) 5, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 135 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminum housing such that led junction temperature shall not rise above 90 c). 45 watt

Central Government/Public Sector

CTN :45382816 Due date: 22 Jun, 202622 Jun, 2026 43.00 Lacs
Tender For corrigendum : special repair for replacement of old hpsv hpmv cfl street light with new led street light fittings and allied work in certain unit at mil stn jaisalmer
 Loading, Please wait...

Connect us via What's Up