Get complete information related to latest Laser Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Laser Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Laser Meter Tenders.
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
Tender For miscellaneous items for hpb and liver transplant surgery ot - radiopaque gauze :-should be sterile gauze & made up of 100% cotton gauze fabric type ep 17- x ray detachable should be weaved x ray 100% barium sulphate or metal it should be lint free, non irritating, latex free, and tissue size:- 10*10 cm*12 ply lint free non pack size 1*4 pc., vircyl sutupac 1, 1-0, 2-0 ,3-0 ,4-0, cautery pincil size 9 , electro surgical cautery tip cleaner, micro suction tip canula, liver biopsy gun, c. arm camera cover, usg prob cabel and camera cover, trolley covers, mayo trolley covers, pounch- opsite drap pouch drape:- 2 incise film provides continuous broad-spectrum antimicrobial activity to help reduce the risk of surgical site contamination incise drape adheres to the operative site, creating a sterile surface at the beginning of surgery 360-degree pouch provides optimal fluid collection to minimize contact with fluid and helps reduce the risk of contamination to or team pouch allows for easy clean-up and saves time comes with tube and cord organizers. a clear, plastic, 360-degree fluid collection pouch with tube and cord organizers. size 30*30 cm, steridrip (basic surgical pack), inj. methylene blue 1.0% 10ml ampoule, inj. albumin 5% (100ml), inj. calcium chloride (100 mg/ml), inj. diltiazem (5 mg/1ml, inj. phenylephrine (10mg/1ml) in ampoule size, inj. dns 500ml (double layered sterile plastic polybag), inj. dns 500 ml ( in sterile double layered sterile plastic polybag), inj. ns 500 ml (in sterile double layered sterile plastic polybag), inj. ns 500 ml (in sterile double layered sterile plastic polybag), inj. ns 1000 ml (in sterile double layered sterile plastic polybag), inj. ns 1000 ml (in sterile double layered sterile plastic polybag), 0.33 ns (double layered sterile plastic polybag), 0.33 dns (double layered sterile plastic polybag), 3% ns (double layered sterile plastic polybag), inj gelofusion 500ml, single arterial & cvp pressure transducer ( compatible with edwards continuous cardiac output monitor ) one disposable pressure transducer having gold plated connector tip for best signal quality with flush device & vent stopcock, iv set, 2 three way stopcocks it should have special hood to reduce contamination risk. gold-plated connector wires for high-fidelity signal transmission. available with a snap-tab flush device that can be easily gripped and stretched 360 to quickly and easily flush the system and generate a square-wave test pattern. it should have a flow rate of 3 +/- 1 ml/hr under 300 mm hg iv bag pressure. should be usfda approved., arterial catheter 3fr-l-8cm usfda approved, gamjee roll, ky jelly, l-70 for fluid warmer set, d1-100 tubings for rapid fluid transfusion, hd catheter (size : 11.5 | 8.5 | 9 | 9.5 |10 | 10.5 ), et tube with suction port (size : 7 | 7.5 | 8 | 8.5), single pressure transducer with closed blood sampling system adult(vamp kit) one disposable pressure transducer having gold plated connector tip for best signal quality with flush device & vent stopcock, iv set, 1 shutoff valve, 60 patient pressure tubing along with inbuilt inline 12 cc reservoir & 2 self-sealing z-site sampling ports located 13 and 55 from patient for closed blood sampling; pole mountable. it should have special hood to reduce contamination risk. gold-plated connector wires for high-fidelity signal transmission. available with a snap-tab flush device that can be easily gripped and stretched 360 to quickly and easily flush the system and generate a square-wave test pattern, patient dress anti-bacterial ,anti-virus and anti-fungi :- fabric should be effective against bacteria , viruses, fungi, absorbency factor of less than 1 sec as per aatcc-79.has moisture wicking factor of 5 sec as per aatcc 197, fabric made up of 94% polyester ,6% spandex and 180 gsm +/-5% , free from toxin substances , breathable , skin friendly, antiseptic property ,should be iso 13485, cdsco & ce approved. size :- small to xl, pressure
Tender For btps - chp - preventive and breakdown maintenance of coal sampling system, ventilation system at mcc-3 and erh, de system-1,2,3,4 at bunker floor required in mm-iii sub division of mm/chp/btps for the period from 01.04.2026 or actual date of commencement of work to 31.03.2027
Tender For purchase of civil lab equipments - equipments for lab, direct shear machine:standard compliance:the equipment shall conform to bureau of indian standards is 2720 (part 13) and equivalent astm international astm d3080.technical specifications:shear box size:60 mm 60 mm 25 mm specimen size (complete with grid plates, porous stones, and specimen cutter).normal load capacity:minimum 5 kn with loading yoke and calibrated loading hanger set.shear load capacity:minimum 2.5 kn or 5 kn with calibrated proving ring (with calibration certificate).rate of strain (shear displacement):variable speed drive with controlled displacement ranging from 0.01 mm/min to 1.25 mm/min (motorised model preferred for uniform rate control).displacement measurement:horizontal displacement dial gauge: 0.01 mm least countvertical displacement dial gauge: 0.002 mm or 0.01 mm least countloading frame:rigid, heavy-duty loading frame with corrosion-resistant finish.drive system:motorised with single phase 220 230 v, 50 hz power supply.accessories (to be supplied complete):shear box assemblyproving ring with calibration charttwo dial gaugesloading weights and hangerporous stones (2 nos.)specimen cuttertool kit, auger boring (or) any boring -soil sampling apparatus: engine type: 4-stroke, air-cooled, single-cylinder petrol engine displacement: 196 cc power output: minimum 6.5 7 hp ( 3.5 kw) maximum engine speed: ~3600 4000 rpm starting system: recoil (manual) start fuel type: pure petrol fuel tank capacity: minimum 1.5 1.6 l supported auger bit sizes: 4 , 6 , 8 , 10 , 12 , 14 (100 350 mm) bit material: heavy-duty mild steel with powder coating typical drilling depth: minimum 3.5 4 ft per bit (800 mm 1.2 m) bit coupling: quick-coupling system for easy bit replacements frame: robust tubular steel frame with ergonomic handles and vibration absorbers weight: minimum 20 22 kg (without auger bit), flow table test apparatus: dimensions and specifications as per is 9103, table top made from flat metal plate ,minimum thickness 1.5 mm, table top size:700 mm*700 mm ,with flatness tolerance of 1.5 mm.table top marked with: scribed cross at centre,lines parallel to table edges and central circle of 200 mm diameter underside of table top reinforced to prevent distortion. total mass of table top:16+_ 1kg table top base frame front and upper stops provided as per is 9103. lower front edge fitted with two rigid stops to transfer load directly to base frame. base frame designed to transfer impact load directly to supporting surface. minimizing bounce stop watch-digital -2 nos scale 1 mtr-2 nos mounting wooden platform 300 mm height amc for 3 years inclusive., drying oven:temperature range: ambient (room) up to 250 temperature control: digital pid controller / thermostat for accurate heating. prestogroupaccuracy: typically 1 2 c. chamber material: stainless steel inner chamber for durability and easy cleaning. air circulation: forced convection fan for uniform temperature. shelves: usually 2 3 adjustable shelves. power supply: single phase 220 230 v ac, 50 hz.
Tender For supply of fittings for closed sampling system - fittings for closed sampling system 1 , fittings for closed sampling system 2 , fittings for closed sampling system 3 , fittings for closed sampling system 4 , fittings for closed sampling system 5 , fittings for closed sampling system 6 , fittings for closed sampling system 7 , fittings for closed sampling system 8 , fittings for closed sampling system 9 , fittings for closed sampling system 10 , fittings for closed sampling system 11 , fittings for closed sampling system 12 , fittings for closed sampling system 13 , fittings for closed sampling system 14 , fittings for closed sampling system 15 , fittings for closed sampling system 16 , fittings for closed sampling system 17 , fittings for closed sampling system 18 , fittings for closed sampling system 19 , fittings for closed sampling system 20 , fittings for closed sampling system 21 , fittings for closed sampling system 22
Tender For supply of capillary sampling connector required for fsds system as per rdso/2008/cg-04 confirming to make tayal & co. [ warranty period: 30 months after the date of delivery ] ]
Tender For procurement and installation of seed testing lab equipment at dr. ysr seed research and training centre, gannavaram, krishna dt. - digital moisture meter (gac gi 2100 or equivalent), cabinet type germinator, single chamber germinator, sample steel trolleys, vacuum seed counter, digital thermo hygrometer, armed illuminated magnifier, petri dishes, sample trays, moisture meter (dickey john small) m20p, ro unit (purified water), weighing balance, purity work boards, computer system, seed divider (boerner type), table top balance, forceps 6inches, spatula 6 (nickel plated), brush, seed sampling probes (triers set), hand screen, stereo scopic binocular microscope, seed blower, watch glass, desiccator, moisture bottle, hot air oven, portable humidifier, spray pump, refrigerator, seed scarifier, rakes and scrapers for seed germination in sand, walk-in germination chamber (15ft*11ft*9ft), x-ray machine / unit, incubator (plant growth chamber), dark chamber setup, weighing balance (analytical), documentation cabinet, autoclave, hot plate, hd trend microscope tagerino, smart phone based grain vernier, planting and counting boards (small/ medium/ large), laminar air flow cabinet, steel racks, storage cabinets, germination racks, lead seals