Get complete information related to latest Latex Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Latex Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Latex Tenders.
Tender For motor and pump maintenance along with material supply for bhor municipal council - rewinding of different capacity motors, 90 h.p, 60 h.p, 50 h.p, 25 h.p, 12.5 h.p, 10 h.p, 7.5 h.p, 5 h.p, 2 h.p, supply of bearing no. 6318, supply of bearing no.7322, supply of bearing no. 6316, supply of bearing no.7320.13, motor dismantling and repairingand erection, 90 h.p, 60 h.p, 50 h.p, 25 h.p, 12.5 h.p, 10 h.p, 7.5 h.p, 5 h.p, 2 h.p, repairing of 90 hp v.t. pumps -dismantling and repairing and erection of following capacity v.t. pumps with bowl assembly , column pipe ,shaft, bearing ,bushing as par sapplied including all cost of skilled labour, transportation, loading unloading and all applicable taxes (old scrap material should tekan by contractor and cost of scrap should deduct and final offer should quote), repairing of 60 hp v.t. pumps -dismantling and repairing and erection of following capacity v.t. pumps with bowl assembly , column pipe ,shaft, bearing ,bushing as par sapplied including all cost of skilled labour, transportation, loading unloading and all applicable taxes (old scrap material should tekan by contractor and cost of scrap should deduct and final offer should quote), supply of various parts for 90 h.p pump stuffing box bronze bushing., supply of various parts for 90 h.p pump gland sleeve s/s material., supply of various parts for 90 h.p pump top bowl repair with providing and welding of m.s. flange heavy duty with required sundry etc., supply of various parts for 90 h.p pump column pipe repair with welding if ribs m.s. flange with machining etc., supply of various parts for 90 h.p pump rubber bush, supply of various parts for 90 h.p pump shaft sleeve s/s material, supply of various parts for 90 h.p pump providing and fixing special strengthening heavy duty nut bolts., supply of various parts for 90 h.p pump rubber packing (chanmpion), supply of various parts for 90 h.p pump neck ring brass., supply of various parts for 90 h.p pump bowl bush rubber., supply of various parts for 90 h.p pump bowl bush brass., supply of various parts for 90 h.p pump impeller., supply of various parts for 90 h.p pump impeller turning, supply of various parts for 90 h.p pump spider bushing, supply of various parts for 90 h.p pump bowl assembly fitting, tafflon gland, supply of various parts for 60 h.p pump stuffing box bronze bushing., supply of various parts for 60 h.p pump gland sleeve s/s material., supply of various parts for 60 h.p pump top bowl repair with providing and welding of m.s. flange heavy duty with required sundry etc., supply of various parts for 60 h.p pump rubber bush, supply of various parts for 60 h.p pump shaft sleeve s/s material, supply of various parts for 60 h.p pump providing and fixing special strengthening heavy duty nut bolts., supply of various parts for 60 h.p pump rubber packing (chanmpion), supply of various parts for 60 h.p pump neck ring brass., supply of various parts for 60 h.p pump bowl bush rubber., supply of various parts for 60 h.p pump bowl bush brass., supply of various parts for 60 h.p pump impeller., supply of various parts for 60 h.p pump impeller qualate., supply of various parts for 60 h.p pump spider bushing, supply of various parts for 60 h.p pump bowl assembly fitting, repairing of starter, rewinding of 90 h.p. starter trasformer capacity with f class copper wire insulation including air drying ,varnishing with dr. bake warmish, backtoling, including all cost of skilled labour, dismantling trasformer transportation , loading, unloading, erection, and giving trial and testing and applicable of all taxes. (old scrap material should tekan by contractor and cost of scrap should deduct and final offer should quote.), rewinding of 60 h.p. starter trasformer capacity with f class copper wire insulation including air drying ,varnishing with dr. bake warmish, backtoling, including all cost of skilled labour, dismantling trasformer transportation , loading, unloading, erection, and giving trial and
Tender For corrigendum : supply of handpump spare parts at pune zp - supply of handpump spare parts, die set 12mm with handle & bits, hydraulic vice 32 mm., heavy duty clamp 32 mm, heavy duty clamp 65 mm, connecting rod vice, pipe lifter spanner for 32mm n.b.pipe., pipe wrench 300 mm, pipe wrench 450 mm, pipe wrench 600 mm, pipe wrench 900 mm, double ended open jaw spanner 17 * 18 in c.v. steel, hacksaw frame, pump bucket (nitrile) for deepwell hand pump(is: 15500 part 7), sealing ring for deepwell handpumps (is: 15500 part 7), hex nut with bolt m 12 * 40, handle axle along with nut & washer for deepwell hand pump (is: 15500 part 4), single side shielded bearing confiming to is: 15500 part 4 suitable for above handpumps, chain nut with bolt m-12x40 (is: 15500 part 4), chain with coupling for deep well hand pump, head for deepwell hand pump (is: 15500 part 4), third plate suitable for deepwell hand pump (is: 15500 part 4) (im-ll), water tank for deepwell hand pump (is: 15500 part 4) (im-ll), connecting nrod of 12 mm dia. x 3 mtr. length, i.s.i.marked galvanized steel tubes as per i:s 1239 ( part-1) /2004 amdt.1 to 4 scrwed at both ends as per i:s 554/1999 ( reaffirmed 2004) . one end socketed with isi marked socket as per is:1239 ( part -ii)/1992 ( reaffirmed 2003) and other end protected with plastic thread protector medium class , bore size (nominal)diameter 32 mm , length 3 meter, cylinder assembly i.m.ii, cylinder body with brass liner for deepwell hand pump (is: 15500 part 5), reducer cap for deepwell hand pump (is: 15500 part 5) (im-ll), upper valve along with rubber seat for deepwell hand pump (is: 15500 part 6) (im-ll), upper valve assly suitable for deep well hand pump (im-ll) (is: 15500 part 6) (im-ll), lower valve assembly i.m.ii, hacksaw blade (high speed steel), spacer g.m. i.m.ii, rubber seat lower valve (im-ll), rubber seat upper valve (im-ll)
Tender For supply of dressing retention elastic tape color white dimensions 10 cm x 10 mtr, material polyester sterility,made of soft, non-woven fabric coated with a non-sensitizing latex-free acrylic adhesive.strong adhesiveproperties.wave-slit paper backing.conforms well to body contours and will not restrict movement.remains secureeven in post-application damp conditions such as sweat and light rain.allows for quick and efficient application. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : tender for supply of different types of consumables - sticky mats 2feetx3feet 30mat pad , cotton sterilies 400 grms bun , lens kimwipes 41 by 2 inch 81 by 2 inch box , soft tissue paper roll 8 x 250 m , oil tissue paper size 30x20 , lens cleaning cloth , lint free cloth aprons colour blue , clean room caps disposable , finger cots medium 546087111880s , powder free latex gloves
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep