Web Analytics Made Easy - StatCounter

Lcd Display Repair Tenders

Get complete information related to latest Lcd Display Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lcd Display Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lcd Display Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40071789 Due date: 19 May, 202519 May, 2025 NA
Tender For providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above supplied stab

CTN :39873036 Due date: 12 May, 202512 May, 2025 NA
Tender For corrigendum : tender for supply of spares of steering gear system acos afas hts ipms and switchboard 22blec001 - mn0 22e contr. relay 24 v dc , tp mcb , 115v ac , 400hz , 20a , 110v dc , 22e mn0 contactor , 7.5 inch hmi display , green push button , cylinder pin-2 , packing for rail , packing for inner rail- curve , packing for platform , 12 v dc green indication lamp 22.5 , phase reversal relay , control transformer 380/240v , 500va , analog input module , coil mnx 185/225 110v ac 50hz , roller assembly , on delay timer , roller lever limit switch , roller lever limit switch , cover for lug , 851ph photo-heat detector marine , toggle switch , 0-400a , ammeter , ctr 400/1a ae , 0-400a , control transformer 380/240v , 2500va , c power acb 2500h , mpr300 , 1-2.75a , 240vac , 3ph , 50hz , dn2-250n 125a 3p mccb , cover for lug , 811f mx flame detector , adressable combine heat and optical detector , ac lamp , digital output module , interposing relay , dn2-250n 80a (6-10in) 3p mccb navy , push button , contact elnt , no , hf fuse link 6a , packing for platform , packing for rail , packing for rail , luffing cylinder seal , push button , diode , hrc fuse link (4a) , eapl 2c10 delayed , 0.3 sec-30 min , a1d1 , mo 0 (4no) contactor , 240 vac , 50/60 hz , led lamp , green 22.5mm , 240vac , variable thermostat 230v 20a , interposing relay , 2 c/o , no contact element , dn3-630n , 630a , 3p , mccb , bush , straight rail - outer , hrc fuse , fuse link (6a) , auxiliary relay re300 (dc) , tp mcb , 115v ac , 400hz , 10a , hydrobar sensors 85 degreec c side mounting 0.4bar 4m cable , insulation monitor
 Loading, Please wait...

Connect us via What's Up