Get complete information related to latest Lead Joint Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lead Joint Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lead Joint Tenders.
Tender For certain repairs to water supply distribution lines and other connected items at zone c at mil stn bhuj and gandhidham under ge(a) bhuj - taking up u/s ac/gi/di/upvc water main (incl all fitting) with spigot & socket /ms pipe or any other type of pipe or leadjoint incl burning out joint & recovering lead from pipe of 200 mm bore for laying /rerouting of serviceable pipe after cleaning complete all as specified and directed., all as per item 1 above but 150 mm dia bore complete all as specified and directed., all as per item 1 above but 100 mm dia bore complete all as specified and directed., all as per item 1 above but 80 mm dia bore complete all as specified and directed., all as per item 1 above but 50 mm dia bore complete all as specified and directed., material and labour di pipes of size 200 mm bore with spigot and socket end centrifugally cast class "k- 7" , in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as specified and directed., material and labour di pipes of size 150 mm bore with spigot and socket end centrifugally cast class "k- 7" , in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as specified and directed. note: di fitting /leadjoint / tyton joint will be measured and paid seperately all the dismanted / demolished /taking down material shall be reused or removed from site., all as per item 7 above but 100 mm dia bore complete all as specified and directed., supply and fixing in any length upvc pipe 150 mm dia pipe manufactured as per astm-d-1785 as per is-559, schedule-40 complete with fittings, laid in trenches in required length complete all as specified and directed., all as per item 9 above but 100 mm dia bore complete all as specified and directed., all as per item 9 above but 80 mm dia bore complete all as specified and directed., all as per item 9 above but 50 mm dia bore complete all as specified and directed., m&l di bend any type radius and angle tapers any type straght bend increacing decreacing or double socket etc) tee pipe single branch y juction double branch cross(all socket and spiogat collars caps and plug for the pipe socket & spiogat of pipe size upto 200 mm dia complete all as specified and directed. ( lead /gasket for fitting shall be measured and paid separately), s & f in repair upvc ball valves with operating handle (stop valve) of size 50 mm dia complete suitable for fittings with astm - 1785, schedule 40 upvc pipes complete all as specified and directed., s & f in repair upvc ball valves with operating handle (stop valve) of size 80 mm dia complete suitable for fittings with astm - 1785, schedule 40 upvc pipes complete all as specified and directed., excavation in trenches in soft / loose soil nexc 1.5 mtr wide and not exc 1.5 m in depth etc complete and getting out in soft soil inciuding trimming sides and bottom of trenches complete all as specified and directed., rentring filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as specified and directed., removing excavated surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed., hard standing cutting/road cutting for laying of pipe and making surface good with pcc 1:3:6 complete all as specified and directed., taking down carefully cast iron sluice valve of size 80 mm to 200 mm bore from ci water mains, complete with all acessories complete all as specified and directed., s&f in repair sluice valves flanged end, cast iron body, flanged and drilled and non rising type stainless steel spindle with nut, long body, class p n 1.6, conforing to is 14846 of 2000 for following sizes including all flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water
Tender For corrigendum : supply of jacket divers dress neoprene 3mm thickness medium , jacket divers dress neoprene 3mm thickness large , jacket divers dress neoprene 3mm thickness small , long john diver dress neoprene 3mm thickness medium , long john diver dress neoprene 3mm thickness large , long john diver dress neoprene 3mm thickness small , boots divers dress neoprene 3mm thickness small , boots divers dress neoprene 3mm thickness medium , boots divers dress neoprene 3mm thickness large , hood for divers neoprene 3mm thickness each set having one each in three sixes s,m and l , gloves for divers neoprene 3mm thickness each set having one each in three sixes s,m and l , mask swim silicon , tube snorkel , swim fins rubber set of pair , swim fins improved graphite with back strap set of pair , swimmer knife with sheath light and rustproof , multipurpose divers knife tool with sheath , underwater digital video cameras with casing , divers life belt , weight belt diver with four or six pouches , buddy line with inglefield clip , lead weight set of 1 and 2 kg , diving ladder adjustable , diving marker float spherical buoyancy 10kgs , iron sinker with hook 25kg , divers lifeline 8mm sisal or manila or manmade fiber length 220m continuous in each set , underwater flood light 1000 watts complete hand held , uw light high power with cable 50 mtrs and surface supply accessories , lamp search divers complete head mounted with rechargeable battery charger and bulb 50 watts , divers uw communication system with battery compatible with diving set , divers uw wireless communication system , portable hp diesel driven diving air compressor 5 to 6 cfm with 5 years spares working pressure up to 300 bars , lp washing kit with 60 feet soft hose and adjustable pressure nozzles , underwater digital still camera with casing , onboard spares , installation and commissioning spares
Tender For certain repair to water supply distribution lines and other connected items at mil stn bhuj and gandhidham under ge (a) bhuj - taking up u/s ci /di/ac water main (incl all fitting) with spigot & socket /ms pipe or any other type of pipe or leadjoint incl burning out joint & recovering lead from pipe of 400 mm bore for laying /rerouting of serviceable pipe after cleaning complete all as specified and as directed., all as per item 1 above but 250 mm dia bore complete all as specified and as directed., all as per item 1 above but 200 mm dia bore complete all as specified and as directed., all as per item 1 above but 150 mm dia bore complete all as specified and as directed., all as per item 1 above but 100 mm dia bore complete all as specified and as directed., material and labour di pipes of size 400 mm bore with spigot and socket end centrifugally cast class "k- 9" , in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as specified and as directed., all as per item 6 above but 250 mm dia bore complete all as specified and as directed., all as per item 6 above but 200 mm dia bore complete all as specified and as directed., all as per item 6 above but 150 mm dia bore complete all as specified and as directed., all as per item 6 above but 100 mm dia bore complete all as specified and as directed., material and labour di pipes of size 200 mm bore with spigot and socket end centrifugally cast class "k- 7" , in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as specified and as directed., all as per item 11 above but 150 mm dia bore complete all as specified and as directed., all as per item 11 above but 100 mm dia bore complete all as specified and as directed., m&l di bend any type radius and angle tapers any type straght bend increacing decreacing or double socket etc) tee pipe single branch y juction double branch cross(all socket and spiogat collars caps and plug for the pipe socket & spiogat of the following size 250 upto 400 mm dia complete all as specified and as directed., all as per item 13 above but upto 80 to 200 mm bore complete all as specified and as directed., m&l for run laid laid joint for ci pipe of size 100 mm bore complete all as specified and as directed., m&l for run laid laid joint for ci pipe of size 150/200 mm bore complete all as specified and as directed., m&l for ruber gas ket joint/ tyton joint for ci / di pipe of size 250 to 400 mm bore complete all as specified and as directed., m&l for ruber gas ket joint/ tyton joint for ci / di pipe of size 80 to 200 mm bore complete all as specified and as directed., taking down carefully cast iron sluice valve of size 250 mm bore from ci water mains, dismantling parts and reassembling, replacement of brass spindle for sluice valve, class pn 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc complete all as specified and as directed., taking down carefully cast iron sluice valve of size 200 mm bore from ci water mains, dismantling parts and reassembling, replacement of brass spindle for sluice valve, class pn 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc complete all as specified and as directed., taking down carefully cast iron sluice valve of size 150 mm bore from ci water mains, dismantling parts and reassembling, replacement of brass spindle for sluice valve, class pn 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc complete all as specified and as directed., taking down carefully cast iron sluice valve of size 100 mm bore from ci water mains, dismantling parts and reassembling, replacement of brass s
Tender For corrigendum : annual repair and maintenance of public health services at iit delhi - a/r & m/o public health services at iit delhi. sub-head:-repair of c.i/d.i and g.i water supply pipe lines, p/f sluice valves,gate valves , leadjoints ,mechanical joints etc. for smooth running of the water supply system at iit delhi.
Tender For repairing and overhauling of one no twin lobe air blower assembly and renovation of 2 nos outgoing motor (blower ) feeder of lt pdb with supply, fitting and fixing spares at sludge pump house under swtp, kmda. - supply,installation,testing and commisioning of following items for hoisting system/ blower and gear box as mentioned below as per direction including cost of materials, machinaries , manpower, cutting,machining,aligning,anchoring,welding,finishing,consumables, carriage and all overheads with all leads and lifts complete as per specification (without painting), i) base frame (ms), ii) shaft/pin with key ways made of ss-304, iii) gear& pinion (forged steel), supply and fixing the 3way c.i v grooved pulley with complete mechanism key way suitable to en-24, 60 mm dia/ as per sample of shaft end., a) motor driving, b) blower driving, supply of gear oil as per direction of engineer in charge., supply of grease, supply and delivery of the following bearing (make: skf):, i) 22312e/c3/ as per sample. (for blower), supply and fixing of tough v belts (make: fenner/power boom / v guard/benq/ecodrive) of the following size c 98/ as per sample., supply fitting fixing of ss (aisi304) bolts,nut & washer i) dia 10 mm to 20 mm a) length upto 75 mm, refixing of impeller of blower after dynamic balancing in workshop as per is rule after dismantling the same., dismantling the 25/30 h.p (18.5 kw)//30 h.p squirrel cage motor from its foundation by opening mounting bolts and disconnection of cables from terminal box and open the v belts for repairing purpose (in condition), preliminary checking of the whole motor (lt sq. cage im) and testing of i.r. value, load currents, leakage factor of stator & rotor, terminal leadjoints of stator connection ends, insulation of glass fibre terminal bar, double cage rotor end rings and all of motor bars and bar joints, housing of d.e. & nde shield bearing housing etc. before work to detect fault., complete servicing and heat varnishing of 415volt, 3 phase l.t. sq. cage induction motor after cleaning the stator and heating it up periodically and varnishing by dr. beck s graded insulating varnish to obtain stable ir value, cleaning up the rotor, including heating for demoisturisation, lacker coating on the surface of rotor stampings, cleaning and ro priming on the end shield covers, bearing housing and complete the necessary repairing works as per direction of e.i.c.upto 75kw lt sq. cage im ], re fixing the 25/30h.p star/delta squirrel cage motor over its foundation by mean of mounting bolts & nuts, washer complete connection of existing led of cable at the terminal box and wear the v belts with proper alignment in respect to i.d. fan (12000 cu m/hr capacity)/ blower by adjusting the side rail for smooth running., finishing the end of terminal leads by s & f dowells copper sockets properly supplying tapes, petrollium jelly etc. 6 nos.upto 75kw lt sq. cage im., cost of mechanical work viz. shaft truness, checking key way looping of holes grinding and polishing etc. upto 75kw lt sq. cage im., inspection checking/testing and servicing of the existing starter panel, all terminal connection, contactors, relays etc as per desired technical specification including man and minor materials for proper functioning as per direction of eic., supply and fixing of 240/230 volt, 50 hz, t.p., power contactor (make: l & /abb/schneider/ simence/ ge) having contact block of the following range.32-55amp, supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) blue/ white color., supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) other than blue/ white color., supply and delivery of thermal overload relays (make: l & t/abb/schneider/simence/ ge/minilec) of the following range:a) 0.2-0.33/ 0.3-0,5/ 0.45-0.75, mn2, supply of ammeter selector switch current in each phase with off, 4 pos. 90 angle ofthrow (off-r-y-b) , supply and fixing of analog ammeter ranging
Tender For annual mtc of water supply,sewerage and swd in sec- 29, ggm for the year 2025-2026.rectification of leakages of water line of various sizes by providing and fixing of cid joints,leadjoints and providing and fixing of ci/di specials in sec 29 ggm