Get complete information related to latest Learning Material Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Learning Material Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Learning Material Tenders.
Tender For corrigendum : procurement of high pressure globe valves and nrvs for boiler and turbine for unit no. 1 and 2, at sgtps, mppgcl, birsinghpur.
Tender For corrigendum : tender for supply of bulb 24v 40w b15 , bulb 40w , glass globe joint , o ring joint , bulb 115 60w b22 , bulb 24 v 40 w b15 , bulb 24 v 40 w b15 , bulb quartz iode 120v 250w , optical class , optical glass joint , pressure switch sensing element for fplm34dtxnsn , pressure switch sensing element for fplm34dkxsn , pressure switch sensing element for fpm34dqxnsn , temperature switch sensing elements for fcm34dgnsn , temperature sensor type pt 100b with ss316ti heath , configurable electronic module with pcb for emi protections , programmable temperature detector with 110mm probe length , temperature sensor assembly without electotronic module lm 176 , temperature sensor assembly without electotronic module lm 196 , flowrate signal processing unit amesys internation , typr 14p limit switch with a 20 m cable , 24 v aquacel type l37 reserve battery , pressure transmitter 0 15 bar absolute g 1 4 female , proximity detector neb 12 18mg50 e2 , remote thermometer 100mm type form 0 to 100 deg g full , thermometer 0100mm type a 0 to 100 degree c fcapillary k 2 m , manual call point , smoke detector , input module , limit switch contact , 1 0 m maximum height fresh water tank 1 level gauge , absolute pressure switch , conduct electrode h20 detect device al threaded coupling , differential pressure switch sensing element , electronic for fmb52 , electronic insert fel54 relays dpdt , level transmitter fmb52 , level transmitter fmb52 , position detector end valve fresh air pipe cm e 14 g21 3 , posn detector end vv air pipe cm e 14 g21 3 , pressure switch sensing element , pressure switch sensing element , pressure switch sensing element , pressure switch sensing element , pressure swith sensing element , pressure 60l alimentary quality balloon horiz or vert , dc dc converter , relay 2rt10a 28vcc , relay 4rt10a 28vcc , relay tpr2 28vcc , relay 6rt10a 28vcc , relay 6rt10a 28vcc , fuse series psc type 6 6 urd 30 tt f 0200 , cartridge fuse ha22 type 6 3 32 6 3 a , cartridge fuse ha22 type 6 3 32 1 6 a , monostable relay 10a 28vdc type 4 i 10 b1 p 28 , berard acturator oa8 115b 60 hz 3ph marline ral7038 , 115v 24 vdc converter , relay2rt 10a 28vdc suppressed device saphir code rel005appar , relay4 rt 2a 28vdc dc p
Tender For corrigendum : supply of cast carbon steel tpattern globe valve of size 3inches with full bore , cast carbon steel non-return flap valve of size 3inches with full bore , cast carbon steel tpattern reg.globe valve of size 2.5inches with full bore , cast carbon steel tpattern globe valve of size 2.5inches with full bore , cast alloy steel non-return flap valve of size 2.5inches with full bore , cast carbon steel tpattern globe valve of size 4inches with full bore , cast carbon steel non- return flap valve of size 4inches with full bore , cast alloy steel non-return flap valve of size 4inches with full bore , forged alloy steel tpattern reg.globe valve of size 2inches with full bore
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needle valves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam