Get complete information related to latest Leather Belt Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Leather Belt Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Leather Belt Tenders.
Tender For e-tender for supply of uniform cloths, shoes, socks and sewing of uniform etc - shirting fine(skyblue/white) (remond/m.lal), shirt white (gwalior), coat pant cloth white (siyaram), cloth maroon (normal), trouser black (gwalior), cloth white trouser & achkan (siyaram), woolen blazer maroon kamarband (ocm), woolen blazer n.blue for achkan (ocm), terry wool suiting trouser, off white (ocm), safari gray and brown (gwalior), suiting cloth white chef coat (gwalior), saree nevy blue & gray (normal), serge cloth black & n.blue & brown (modella), trouser fine light grey (anchal, l. grey), pettycoat nevy blue & grey (normal), shirting kurta white & grey & brown (normal), shirting salwar black & grey & brown (normal), shirting woolen kurta/salwar grey & brown (normal), dupatta black & grey & brown (normal), ties black (normal), miscellaneous apron black white check (normal), miscellaneous pagri cloth (normal), leatherbelt black with ashoka emblem (complet set), p-cap with ashoka emblem (complet set), coat stiching, shirt stiching, trouser stiching, achkan stiching, kamarband stiching, coat pant stiching, safari suit stiching, salwar /kurta stiching, blowes stiching, chef coat stiching, black shoes for gents, black shoes for ladies, shoks black (normal)
Tender For supply of green coat and pant with zari decoration, nehru cap & name plate , coat button with ring , pagri regimental , title shoulder itbp , formation sign itbp , itbp motto zari , band master pea cap , band master zari belt , band master shash , shoulder appellate golden zari , dress cord golden zari , leatherbelt with buckle , itbp motto , northern frontier formation sign , itbp shoulder title
Tender For supply of embryo transfer sheath - 9991267, 1000.000, imv make embryo transfer sanitary sheathref. 006458sanitary sheaths are used to protect the sheath during insemination and prevent contact between the ei sheath and the cow.
Tender For supply of consumables of cardiac catheterization lab for gbph, sri vijaya puram - puncture needles (adults), puncture needle for vascular access in adults 18 g 6- 7.5 cm long should be compatible with 0.038 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, puncture needle dedicated for radial artery access in adults 20- 22 g 3- 5 cm long should be compatible with 0.021 - 0.025 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, micropuncture needle for vascular access in adults 20- 22 g 6- 7.5 cm long should be compatible with 0.018 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, micropuncture needle for radial artery access in adults 20-22 g 3-5 cm long should be compatible with 0.021-0.025 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, introducer sheaths (adults), introducer sheath for adults and pediatrics (sizes 4 -9fr.) - standard length sizes 4- 9 fr 10- 11 cm long 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, introducer sheath with puncture needle for adults (size 5- 9 fr) - standard length sizes 5- 9 fr 10-11 cm long pack must include 18 g, 6- 7.5 cm long puncture needle 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, long introducer sheath (size 6- 7fr) 20-50 cm long sizes 6- 8fr sheath should be between 20-50 cm long 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, introducer sheath for radial access introducer sheath dedicated for transradial access sizes 4- 7 fr between 7- 16 cm long 0.021 - 0.025 inch guide wire compatible pack must include 20-22 g, 3.5 cm long puncture needle with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath m coat hydrophilic coating kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, introducer slender sheath for radial access transradial slender sheath systems 5f 10 cm capable of introducing 6f catheter with hydrophilic coating on sheath ,tapering dilator hydrophilic straight polymer 0.025 wires and 20g plastic cannula for puncture . should be fda/ce/dcgi approved, introducer slender sheath for radial access transradial slender sheath systems 6f 10 cm capable of introducing 7f catheter with hydrophilic coating on sheath, tapering dilator hydrophilic straight polymer or stainless steel 0.021 or 0.025 wires and 22 g / 20g plastic cannula for puncture should be fda/ce/dcgi approved, guidewires (adults), ptfe coated diagnostic guide wire - regular length, regular stiffness should be available in 0.025, 0.032, 0.035 and 0.038 inches size should be between 145- 180 cm long should be available as straight & j shape tip should be available in variable lengths of flexible/floppy end should be available in variable j tip sizes should be available in fixed as well as movable core, ptfe coated diagnostic guide wire - exchange length, regular stif