Get complete information related to latest Led Luminaires Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Led Luminaires Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Led Luminaires Tenders.
Tender For supply, installation, testing and commissioning of street light poles including ledluminaires arrangement in the median along phase ii kochi metro corridor from jln metro station to smart city - supply, installation, testing and commissioning of street light poles including ledluminaires arrangement in the median along phase ii kochi metro corridor from jln metro station to smart city.
Tender For tender for supply of ledluminaires - 350w led flood light , 200w led flood light , 90w led street light , 150w led street light , 200w led street light , 300w led flood light , 400w led flood light
Tender For maintenance of electrical installation and fans, repair and maintenance of p/set in cgs colony kane nagar mumbai-37.sh: supply, installation, testing and commissioning of decorative ledluminaires along with allied cable and foundation works in sector 6 garden, antop hill, mumbai-37.
Tender For complete overhaul, upgradation, and modernization of the existing underground tunnel illumination system in the right bank tunnel of bhep stage-ii by way of providing, installing, testing, and commissioning energy-efficient overhead ledluminaires wi
Tender For supply of electrical materials for the repair and maintenance of street light as per the boq - details, t-5 power/energy saver 2x24w choke, t-5 power/energy saver 24w ftl tuberod, 2x24 t5-holder, t5 power saver 2x24 fixture acrylic transparent cover, t5 power saver 4x24 fixture acrylic transparent cover, 150w hpsv choke, 150w hpsv lamp, capacitor 33mfd 250vac 50 hz, electronic ignitor suitable for 150w hpsv lamps, 150w holder (porcelain), led driver 50w bis certified, led mcpcb plate 60w, led mcpcb plate 50w, led mcpcb plate 150w, supplyingof isi marked and approved make of moulded case circuit breaker(mccb) suitable for 3phase,3pole,50hz,415 volts, ac supply with respective interrupting capacity(ka) at 415 volts cited against their range standard conforming to is - 8828: 8.1mccb with breaking capacity 25 ka at 415 v: current rating -125 amps & 70% -100% adjustable, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light sub feeder panels - type 2 pluggable spd 3+1, rating l-n/n-pe uc 255/320 v in 30/60ka ka, lmax 30ka/60 ka, up 1.5kv, supplying of isi marked and accepted standard of miniature circuit breaker(mcb)ofcseries suitable for 240/415volts,50cycle,10ka value ac supply confirming to is:8828:1996,iec:60898 :2002 but without enclosures: single pole 63 amp., astronomical timer with dst feature, contactor 3 pole 90 amp 50hz 415volts with no-nc contacts, tpn connector 150a, supply of approved make powder coated sheet steel encloser spn mcb db inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator): 8 way double door, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light - type 2 pluggable spd 1+1, rating l-n/n- pe uc 230/400 v in 5 ka, imax 10 ka, up 1.2kv, led batten tubelight 20w, supplying of approved make tpn mcbdb metal double door with provision for fpmcb/isolator/rccb/rcbo as incomer and sp mcbs as outgoing inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator ): 8 way (8+24), 8 sq.mm multistrand pvc insulated copper wire bundle 90mtr, 1.sq.mm aluminium single core wire bundle of 100mtr. isi marked, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 2-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 4-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 1-core isi marked with alu. stranded/solid conductor: 25sq.mm unarmoured, wooden ladder 21ft, toolkit set consisting of different sizes l-keys, screw drivers, testers and plier set., taperoll box consisting of 30pcs (conforms to is: 7809 (part 3, sec 1),self extinguishing,protects from electrolytic corrosion,excellent water resistance,suitable for primary ins
Tender For corrigendum : supply of operation and maintenance of electrical and mechanical installations , job contract for operation and day to day maintenance services of airport systems equipments , execution of item of schedule of rates cpwd dsr 2022 as and when required , testing of transformer oil sample including conducting bdv test and submission of test report etc complete as required , filtration of transformer oil of 630 kva transformer , servicing and checking of lt air circuit breaker , servicing and checking of ht vacuum circuit breaker , calibration and testing of relays at ht panel , calibration and testing of following relays at lt and synchronizing panel , scrubbing, cleaning the existing surface of cubicle panel, feeder pillars and painting , lettering of maximum 2 inch size alphabetic or numerical , cleaning the surface of ms chequered plates , supply and replacement of silica gel in breather of existing 630 kva transformer etc. complete as required , lifting and lowering of 10 hp borewell submersible motor pump set , servicing and complete overhauling of 10 hp borewell submersible motor pump set , decoration of terminal building and canopy of rupsi airport , supply and replacement of defective smoke detectors , supply and replacement of defective manual call point , supply of convertor or driver suitable for philips make 20 w downlight types ledluminaires or fittings , supply of convertor or driver suitable for osram make 120w types ledluminaires or fittings , supply of convertor or driver suitable for havells make 18 or 20 w downlight types ledluminaires or fittings , supply of convertor or driver suitable for wipro make 36w 2ftx2ft recess mounted fitting , supply of 1000w 240v lamp suitable for aerodrome beacon , supply of aerodrome beacon , calibration of clinometer , supply of reflector suitable for ama make papi , supply of 2c x 4 sq mm. secondary lead with plug , supply of b connector or four way porcelain terminal , supply of 5 kv grade 50 hz ac isolating transformer , supply of two pin halogen lamp holder suitable for 200 watt , supply of 5 w screw cap led lamp , supply of wind sock cloth , supply and replacement of led flood light , supply and replacement of obstruction light of wind direction indicator , supply and replacement of 180 ah 12 v lead acid battery , supply and replacement of 100 ah 12 v lead acid battery , supply of automaic electric hand drier , servicing, checking repairing overhauling and testing of crompton make 630 kva transformer
Tender For corrigendum : 80 watts led flood light luminaire suitable for outdoor applications, having ip-66 or higher protection and designed to operate on single phase ac supply of 140 - 270 volts at 50 hz +/- 5 hz. the luminaire shall be suitable for operation with portable generator sets used at bd accident spots. the luminaire shall have a minimum efficacy of 130 lumens per watt. the working life of led shall be minimum 50,000 hours supported by lm-80 and tm-21 reports. the led luminaire shall conform to is 16107 / iec 62722, exterior lighting fixtures and accessories for floodlight confirming to is 10322 (part 5/section 5) and the led modules shall conform to is 16103 / iec 62717. ledluminaires shall also be as per lm-79 and lm-80. the item shall conform to specification no. swr/led light fitting (indoor/outdoor)/001-2016. accepted led makes: osram / philips lumileds / cree / lednium / avago. warranty: 5 years, as per specification no. swr/led light fitting (indoor/outdoor)/001-2016. [ warranty period: 60 months after the date of delivery ]