Get complete information related to latest Level Gauge Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Level Gauge Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Level Gauge Tenders.
Tender For supply of electrical spares - electrical spares, digital synchronous timer for switching on/off operation, cycle duration -24 hours, maximum number of switchings 48 on-48 off, contact voltage/current rating- 240vac/16a, changeover contacts- 02 nos. din rail mounting type, minimum time interval 15 min for 24 hrs. make selec, l& t, c&s, abb, havells, legrand only, power contactor 80a, coil voltage-240vac, 1 no-1nc, din mounted , abb, schneider/havells/ lnt/ hager/c&s/legrand/bch only, mcb 16a, single pole, c curve, breaking capacity-10ka, make : abb, schneider/havells/ lnt/ hager/c&s/legrand/bch only, fuse hf type, 32 a, 415 v, fuse hf type, 63 a,415 v, magnetic oil levelgauge (mog) for 12.5 mva rating oil type transformer.size 150mm , suitable for vertical mounting., timer on delay a1d1-x eapl ,3 sec-30min , din rail mounting type, pendent 6 waymaterial: high grade plasticvoltage rating:415 vaccurrent rating:5ampwith emergency stop & start/alarm, with ip65 dust proof for outdoor application, control transformer415/110vac, 500va , winding material - copper , maximum size in mm w x d x h = 160 x 100 x 200 , control transformer415/110vac, 300va , winding material - copper maximum size in mm w x d x h = 160 x 150 x 160, control transformer415/110vac, 1000va , winding material - copper maximum size in mm w x d x h = 150 x 150 x 180, control transformer415/110vac, 3000va , winding material - copper maximum size in mm w x d x h = 200 x 160 x 300, bridge rectifier input voltage 415 vac output voltage 190 vdc, fuse ctis, bolted type, 63 amp , 415 vac, fuse hbc, bolted type, 32 amp , 415 vac, hrc fuse base for 100a hn type fuse , 415 volt, limit switch with 1no + 1 nc , 415 volt , 50 hz , 1.5 amp .these limit switches should be equivalent to original installed model: bc9 t limit switch (jlsla) of jaibalaji make
Tender For supply of differential pressure gauge diaphragm type range 0-250 mm of h2o, case material ss-304 w orking pressure 2.4 bar/35 psi, connection 1/8 [ warranty period: 30 months after the date of delivery ]
Tender For repair and overhauling service - kg5h 230 kpcl; kg5h 230 kpcl; yes; buyer premises, service provider premises-detailed defects: (a) fuel level indicator qty-01 u/s, needs to be replaced. (b) 1st stage (3.7 kg/cm2) qty-02 and 5th stage (264 kg/cm2) safety valve qty02 u/s, needs to be replaced. (c) hooter qty-01 and fire extinguisher qty-02 u/s. (d) charging alternator qty-01 and starter motor qty-01 u/s, needs to be repaired. compressor dip stick qty-01 broken, needs to be replaced. (e) pressure gauges (0-7 kg/cm , 0-21 kg/cm , 0-70 kg/cm , 0-16 kg/cm , 0-400 kg/cm ,0-600 kg/cm ,0-150 kg/cm ,0-150 kg/cm ,0-15 kg/cm ,0-15 kg/cm ) total qty-10 u/s, needs to be replaced. (f) drainage pipelines of dampner qty-06 and purge bottles qty-06 blocked, needs to be replaced. (g) pneumatic door struts qty-20 u/s and door hinges qty-12 broken, needs to be replaced. (h) delivery valve (0-400 kg/cm2) qty-04 and vent valve (0-400 kg/cm2) qty-04 u/s, needs to be replaced. engine solenoid 24v qty-02 and rmp meter qty-01 u/s, needs to be replaced. mechanical jack qty-04 u/s, needs to be repaired. (k) dew point meter qty-01 u/s to be repaired and calibrated. door lock qty-06 u/s, needs to be replaced. (1) charging adopter damaged qty-06 u/s, needs to be replaced. (m) search light qty-04 and panel light qty-06 u/s, needs to be replaced. (n) pre filter differential gauge qty-01 (range 0-1.5 kg/cm2) u/s, needs to be replaced (o) charging alternator, mechanical lubricator and radiator fan belt (qty-03) teared off, needs to be replaced. (p) silica gel of both dryer units saturated and needs to be replaced. pre filter, oil filter and after filter element (total qty-03) to be replaced. (q) air filter, fuel and oil filter element (total qty-03) to be changed..