Get complete information related to latest Leveling Valve Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Leveling Valve Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Leveling Valve Tenders.
Tender For supply of overhauling kit for levelingvalve consisting of 16 items (kb make) as per list- (1) sealing ring part no. b74370/2 qty 01 (2) o ring part no. a27763/26 qty. 01 (3) o ring part no.a75374 qty. 01 (4) washer part no.c68476 qty. 1 (5) grooved pin part no. 476508 qty. 2 (6) lock washer part no. a34546/2 qty. 1 (7) locking ring part no. 466031 qty. 02 (8) toothed ring part no. a62331/6 qty. 1 (9) wire mesh filter part no. a40108 qty. 1 (10) sealing ring part no. 458381 qty 1 (11) wire strainer part no.a51762 qty. 3 (12) sealing ring part no. i.4.631 qty. 1 (13) valve head part no. c71558 qty. 2 (14) compression spring part no. c141622qty. 1 (15) hex head bolt part no. 451728 qty. 2 (16) roller part no. a75281 qty. 1. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of integrated test bench for air spring suspension control equipment ( levelingvalve and duplex check valve) as per specification attached. [ warranty period: 30 months afterthe date of delivery ] ]
Tender For auction sale of depot non ferrous scrap - scrap & condemned miscellaneous cast aluminium i.e.parts of locos,parts of distributor valve, housing assembly,aluminium plate for earthing, steady arm, antiwind clamp housing of wheel set earthing, levelingvalve,junction boxes, blades etc of sort & sizes, complete or incomplete,with or w/o ferrous attachments,as it is, us & ur qty:- 2230.00 kgs loc:- material lying at office area-c,beside room no-e in nbg judw. remarks-[1]delivery will be given by actual weight on electronic weighing scale capacity-1000 kgs. [2]loading by purchaser.
Tender For supply of poh kit for m/s kbil make levelingvalve to part no. ii 68831 and duplex check valve to part no. 1.301902 as per sketch no. emu/mtn/be/17-r4. (one set consist of 21 items having 27 nos in each set, as per annexure attached). [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of installation lever for levelingvalve for air suspension coaches, escorts part no. 2eb-6636, or knorr part no. f-3 -1905 or equivalent. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of levelingvalve complete to rdso drg no. sketch- k1049 alt. -2 & conforming to rdso specno.ck407 rev- 04 [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of over hauling kit for levelingvalve. spec/part no. : knorr bremse parts (ii68831) consisting of items as per attached annexure. [ warranty period: 36 months after the date of delivery ] [ warranty period: 36 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of protection cover for levelingvalve of lhb coaches as per rcf drg.no.- lw36173 alt-'d' or latest. [ warranty period: 30 months after the date of delivery ] ]
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign