Get complete information related to latest Lid Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lid Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lid Scrap Tenders.
Tender For corrigendum : replacement of foam cushion of med exam table , replacement of castor wheel of instr trolley , replacement of sheet cushion and hand rest of wheel chair , replacement of castor wheels of cabinet trolley , replacement of side railing and wheels of advance icu bed , replacement of cutter blade of electric pop cutter , replacement of bp cuffs adult and pead of bp recording unit digital , replacement of ecg electrode and cable of cardiamat 6 channel ecg machine , replacement of battery and electrode cable of ecg machine bpl model cardiart 9108p , replacement of adult spo2 probes temp probe and ecg lead and pead spo2 probe and nibp extension line of multipara patient monitor , change of power battery ecg electrode cable of ecg machine 12 channel , transducer for invasive bp monitor of pediatric and adult multi parameter monitor with etco2 and ibp model contec ) /bid number : gem/2025/b/6496256 * /dated: 07-08-2025 & & / bid document 1 / 13
Tender For technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulse generator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulse generator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulse generator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulse generator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulse generator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulse generator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system should have fda ap
Tender For auction sale of scrap lot consisting of clutch cover all type,scrap lot consisting of brake shoe front & rear assembly,scrap lot consisting of fly wheel w/w.o ring,scrap lot consisting of empty plastic barrels- cut,scrap lot consisting of all sizes of ms radiator tank,scrap lot consisting of empty plastic barrels 210 ltrs cap. w/wo lid,scrap lot consisting of empty plastic barrels 210 ltrs cap.,scrap lot consisting of plastic radiator tank all sizes,scrap lot consisting of plastic air blower frame, battery cover,scrap lot consisting of viscous fan assembly,scrap lot consisting of ms break pipe,scrap lot consisting of dd unit,scrap lot consisting of relay valve,scrap lot consisting of concept valve,scrap lot consisting of dual valve,scrap lot consisting of s p valve,scrap lot consisting of tata ac spare parts,scrap lot consisting of nozzels,scrap lot consisting of a/c spares,scrap lot consisting of a/c body,scrap lot consisting of tata bsiii 352 dia top cover,scrap lot consisting of tata 330 dia top cover,scrap lot consisting of bsiii l/l water pump assembly,scrap lot consisting of axle shafts,scrap lot consisting of air bellow piston only,scrap lot consisting of jk door w/w/o glass,scrap lot consisting of rear axle,scrap lot consisting of fly wheel ring (frp yard),scrap lot consisting of air tank all sizes,scrap wheel disc tata/ley/ eicher,scrap lot consisting of aluminum intercooler with,scrap lot consisting of office old records,scrap lot consisting of marcopolo air drier all sizes,scrap lot consisting of air compressor casing,scrap lot consisting of cylinder liners,scrap lot consisting of bs3 drain assembly bracket,scrap lot consisting of tata connector water inlet,scrap lot consisting of tata bs3 water pump,scrap lot consisting of leyland cooler assembly,scrap lot consisting of leyland & tata automizer pipe,scrap lot consisting of leyland & tata bolt & nut,scrap lot consisting of tata bs3 push rod,scrap lot consisting of tata inlet finger,scrap lot consisting of tata exhaust finger,scrap lot consisting of tata aluminium inlet plate,scrap lot consisting of all type exhaust manifold,scrap lot consisting of leyland fan pully,scrap lot consisting of leyland thermostat bracket,scrap lot consisting of leyland alternator bracket,scrap lot consisting of scrap l/l bs-iv midi
Tender For supply of spares for techno make boiler lifts at ntpc solapur - door sensor,rms-151-p2-0001, door drive,rms171p20002,techno, door motor,rms171p20003,techno, sweep fan,corporate,rms141p20010,techno, overspeed governor,sfg300123,techno, elevator rope,spo650,techno,1088kg, microprocessor card,spo504,techno, auto door cam,sfg400149,techno,elevator, smps,spo357,techno,12v, car shoe,sfg400221,techno,1088kg, scrolling disp card,sfg500127,techno, extension card,rm-421-13-0018,techno, ard contactor,rms-161-p2-0120,techno, 1ph preventer,rm-421-13-0016,techno, vfd,yaskawa,a1000, wire wound resist,rms-161-p2-0727,techno, main pulley,sf-101-50-0123,760mm,techno, main pulley,sf-101-50-0123,890mm,techno, diverter pulley,sfg500541,techno,lift, safety block,jsfi-131-50-008,techno, seg-7 display card,sfg500242,techno, mtr couple pulley,sfi-101-50-0087,techno, main transformer,rmi-161-p2-0011,techno, inspection box,rms181p10016,techno, jaguar/lop,sfg300019,techno, battery,rech,lead acid,1.8v,17ah, limit switch,rms-181-p1-0002,techno, vfd drive v1000,rms-161-p2-0048,techno
Tender For supply of accessories for comen make patient monitor d d - single notch 12 pin adult spo2 probe for star 8000 model or equivalent , single notch 12 pin y type neonate spo2 probe for star 8000 model or equivalent , single notch 12 pin adult spo2 probe for c80 model or equivalent , single notch 12 pin y type neonate spo2 probe for c80 model or equivalent , d type spo2 probe extension and neonate y type spo2 probe nellcor make for c50 model or equivalent , single notch 12 pin 5 lead ecg cable for star 8000 model or equivalent c50 model and c80 model or equivalent , nibp cable with adult cuff for star 8000 model c50 model and c80 model or equivalent , nibp cable with pediatric cuff for star 8000 model c50 model and c80 model or equivalent , nibp cable with neonate cuff for star 8000 model c50 model and c80 model or equivalent , etco2 cable for c80 model or equivalent