Tender For supply and erection of 15 feet gi pipe of 100 mm dia 4.5m thickness of medium quality isi no: 1230(part 1) 1990. having an iron base plate 10 mm thick x 30 cmx 30cm welded at the bottom of the pipe with four supports of iron bars of sizes 10 mm dia. the 3 feet pipe shall be buried in the ground and 12 feet shall be. above the ground. the work includes digging of the pit on platform, laying of cable in between poles in suitable underground gl pipes, erection of pole and filling the pit with 1:3:4 cement, concrete and sand. final plastering should be done on the surface. the iron bracket on the top of the pole shall be provided to fix the cctv camera, protection cover and junction box. the work includes supply of all the materials required in this item. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of junction box to m/s escorts / m/s sona blw part no-1j112000013 as per drg.no. cg-19005 alt 2 specn: rdso/2011/cg-04(rev.04) make:- sona blw precision forgings limited [ warrantyperiod: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of junction box to m/s escorts / m/s sona blw part no-1j112000013 as per drg.no. cg-19005 alt 2 specn: rdso/2011/cg-04(rev.04) make:- sona blw precision forgings limited [ warrantyperiod: 30 months after the date of delivery ] ]
Tender For m. s. under frame electrical inspection junction box cover as per tlw drawing no. tlw/08/11. sample to be got approved before effecting bulk supply. [ warranty period: 12 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of wsp junction box faiveley as per rdso drg. no.cg19005 alt.2 or latest. accepted only oem firm faiveley. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be
Tender For corrigendum : supply of mat code-w90418109206 fibre optic sensor with conditioner& 10mtr integrated cable for generator , mat code- w90418109192 fibre optic sensor with conditioner& 6 mtr integrated cable for generator , mcode -w90418109168 panel & accessories for gen. end winding vibration monit. system bhel , mat code- w90418109176 junction box and accessories for fo end wndg , mat code- w90418109133 commissioning of fibre optic generator end winding vib. monitoring system , mat code-w90418109184 fibre optic generator end winding vibration monitoring system for 24 channels