Tender For design, manufacture, supply, erection, commissioning and testing of swift make 12.5 tonne capacity underslung eot crane, cross travel geared trolley with lifting arrangement with extended type of motor driven trolley with overhanging arrangement at unit-8 mill bay.
Tender For supply of supply of air cooled ducted 16.5 tr ac unit , supply of air cooled ducted 5 tr ac unit , unloading lifting and shifting of 16.5 tr ducted package ac unit at site , unloading lifting and shifting of 5 tr ducted package ac unit at site , installation n2 pressure testing vacummising and commissioning of 16.5 tr ac , installation n2 pressure testing vacummising and commissioning of 5 tr ac , supply and charging of r 410 gas , supply and inst of floor mounted ms stand fabricated out of ms channel , supply and inst of floor mounted ms stand fabricated out of ms angel , hard copper refrigerant piping between indoor and outdoor units , supply and installation of gss ducting as 24g , supply and installation of gss ducting as 22g , acoustic insulation of plenum initial ducting with 10mm thick armasound , supply and fixing of 13mm thick nitrile rubber al foil faced insulation class i , supply and installation of ai powered jet nozzles with volume control damper , supply and inst of ai powered return air grills without volume control dampers , supply and installation of gi opposed blade duct dampers, qty 1.5 sqmtr , supply and fixing of canvas connection , supply and laying of 32mm dia pvc drain piping , electrical cabling 6 c x 1.5 sqmm cu flexible , electrical cabling 3 c x 1.5 sqmm cu flexible , electrical cabling 1 sqmm cu flexible double earthing * /bid number : gem/2026/b/7581741 + /dated: 11-06-2026 ' ' / bid document 1 / 24
Tender For corrigendum : procurement of spares for su-30mki aircraft - transistor, eye bolt for engine lifting sling, tester for checking unit bp-15p & bp-06 (suo block), high frequency unit, plug, launcher p-72 safety pin, pin, outlet pipe line, pyro-mechanism, spring, mbd-3 safety pin mechanical, launch control unit, plug, fitting, fitting, cover, cover, semi-axle assembly, bracket mbs, outlet union from rk
Tender For contract for supply of turbine spares triveni - b supply of set 1st stage nozzle with spacer & end piece supply of welded diaphragm 2nd stage supply of welded diaphragm 3rd stage csm batala make:- triveni tst-1150-hr-29 14 mw, working pressure-87 kg/cm². маx temp.510 c, back pressure part a 1 lub oil filter element 16 micron control oil filter-451gpm-10 micron emergency oil filter element tv lifting spindle bearing rod end bearing spherical speical stud cap nut over speed trip shaft with gear valve for over speed trip & spring solenoid coil 110 v vibration probe extension cable drivers oil filter element for oil mist separator (1 set = 07 nos.) relay 3 c/o 24 v dc unitrol 6080 di converter power supply unit surge suppressor potential transformer, pti-pt3 current transfer, ct9-ct11 ht fuses, hf1-hf3 ht fuses, hf4-hf6 current transformer, ct2-ct4 current transformer, ct5-ct7 check sysnchronising relay auto synchronising no volt relay power contractor, 150a power contractor, 25a field failure relay soft starter power supply unit signal isolator
Tender For corrigendum : rate contract for work of removing, lifting/shifting, o/h & refitting of various sizes of lt motors, ext. fan and actuators installed at unit no. 8 wtps,gsecl on as and when required basis.
Tender For enquiry for procurement of usha martin make galvanised flexible round steel wire endless grommet rope sling for lifting ip turbine rotor of unit 1 and 2 at 2x600 mw at sstpp, mppgcl, dongalia.
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - wt-5138g work for emergency replacement lifting and shifting oh and dismantling of 6600 v ht motors of unit no 3 4 and 5 emd ii utps during running of unit exigencies sh..
Tender For supply of smoke detector unit for power car, as per drawing: edts-087, rev-b, corr 1&2with rcf annexure -br-01, packing instruction: alternator,rru, erru &accessories, transformer,bulk inverters , battery, charger, self priming monoblock pump, inverter, change over control box etc: suitably covered with biodegradable transparent polythene and packed in wooden cage: bottom frame to be made of wooden planks 20mm thick &should have support of at least 3 wooden battons of size 100x100mm of suitable length to facilitate lifting by fork lifter. each panel to be packed in wooden cage of suitable dimensions made out of wooden strips of 20x100mm size. gap between each strip should notbe more then 100mm. the material used for product packaging shall be eco-friendly.a list should be pasted on each wooden cage showing order no, pl no, description of the item, drg. no/ spec. no ,qty, firm's name &address and date of despatch etc. note- 1) firms have option to provide qr code. for linkage of po, the cardboard box shall carry a qr code having details as listed below: a) name of the manufacturer b) purchaseorder number c) purchaseorder date d) uniqueserial number (or lot number for bulk items) of the manufacturer or e) dateof manufacture f) deliverychallan no. g) deliverychallan date 2.the qr code shall be as per iso/iec 18004 model2 and the data shall be available as xml using the tags detailed above. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For bid to ras tender for supply of disconnecting ht and lt supply taking down the defective transformer indoor outdoor type from four pole two pole structure or lifting from the outdoor type foundation or taking out from sub station bldg using a crane of suitable capacity and slings ropes etc as required and shifting the same to civil workshop for repairs complete all as directed for transformer capacity 400 kva , shifting back the repaired transformer indoor outdoor type from civil workshop to site reinstalling at original position and fixing properly on four pole two pole structure or outdoor type foundation or inside a sub station bldg using a crane of suitable capacity and slings ropes etc as required making ht lt side connections and testing for satisfactorily working complete all as directed for transformer of capacity 400 kva , draining out transformer oil from the transformer and storing the same in suitable containers to be arranged by contractor without any extra cost opening the top cover and lifting up the core assembly carefully to check the condition of transformer windings and core retanking the same after repairing checking of leakage from transformer body and repairing welding works required for making transformer body leak proof refilling the transformer oil dully dehydrated and filtered dehydration and filteration to be paid separately and making all connections with ht lt side bushings refixing the top cover and testing the transformer with a suitable capacity insulation tester complete all as directed for transformer of cap 400 kva , m and l for rewinding of burnt out defective ht copper coils with new super enamelled heavy duty copper winding wires of size matching to the existing one including varnishing drying in a suitable oven and all insulating material such as cotton sleeves tapes etc and connections with bushing terminals complete all as specified and directed , all as per item no 4 above but lt copper coils complete all as specified and directed , m and l for painting the transformer tank from inside with two coats of zinc chromite after preparing the tank walls bottom top cover inner side by properly cleaning the surfaces oil free complete all as directed for transformer capacity 400 kva , m and l for replacement of defective ht porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , m and l for replacement of defective lt porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , dehydration and filteration of transformer oil for indoor outdoor type transformers of any capacity at site using transformer oil filteration plant to improve di electric strength not less than 45 kv at 2 point 5 mm electrode gap complete all as directed note unit rate quoted shall be deemed to include the charges for hiring of oil filteration plant shifting to different locations at cantt area testing of samples of oil as per requirement and nothing extra will be paid on this account , s and f new transformer oil for replacement or topping up the level of oil having dielectric strength not less than 45 complete all as specified and directed