Web Analytics Made Easy - StatCounter

Lifting Magnet Tenders

Get complete information related to latest Lifting Magnet Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lifting Magnet Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lifting Magnet Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45473474 Due date: 23 Jun, 202623 Jun, 2026 NA
Tender For supply & fitment of foldable seat for inspecting official for electric loco cab as per rdso modification sheet no. rdso/2023/el/ms/0494 rev-0 dated-september 2023 and installation drg. no.05/1/38/44 alt 9 or latest [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45475154 Due date: 30 Jun, 202630 Jun, 2026 30.00 Lacs
Tender For repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and getting out in an

Central Government / Public Sector

CTN :45473233 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For set of tools required for ac electric locomotive tool box consisting of 07 items as follows. 1) t-spanner along with box(head size: 8mm, length: 100mm) to open sb, hb & battery box etc. qty/set. = 01 no. 2) insulated screw driver flat(head size: 5 mm, length: 300mm). qty/set. = 01 no. 3) combination pliers size: 150 mm x 60 mm. qty/set. = 01 no. 4) multi purpose spanner 43 mm jaw compulsory, length: 380 mm. qty/set. = 01 no. 5) chisel length : 250mm, width : 30mm, thickness : 10mm. qty/set. = 01 no. 6) pin punch(pin dia : 2 mm, pin length : 55 mm, pin handle dia : 10mm, pin handle length : 100 mm). qty/set. = 01 no. 7) ball pein hammer with head weight: 500 grams, wooden handle length : 320 mm, wooden handle thickness : 25 mm. qty/set. = 01 no. makes: deneers/ jhalani/ taparia or its equivalent.[firm must mention the specific make if any for each item separately at the time of tender submission] note: one sample set of each item should be got approved before effecting bulk supply. [ warranty period: 30 months after the date of delivery ] ]

Central Government And Public Sector

CTN :45494457 Due date: 18 Jun, 202618 Jun, 2026 NA
Tender For supply of top seal n type roll size - 8* x 20 mtrs for securing hood of electric loco.as per followingspecification: i)visual tape free wrinkle & visual defect ii) dimension: a) width: 8 inch b) length: 20 mtrs c)thickness: 0-18-0.30mmiv)tansile strength kg (25-30 minimum) v) elongation (%) : 5 minimum vi) adhesive to steel (g/2.5cm): 3000mini. vii)water permeability: not more than two drops after two hours. viii) weather resistance to pass 200 hrs as per saej1900 in std xenon arc base should pass thetest. ix) oil resistance should pass the test.x) alkali resistance shouldpass the test. xi) mvpt as per ind/me/790 (a) the moisture absorption should not be more than 200 g/m square/24hrs at 40 degree c.make/brand- permacel, savvy, johnson & johnson or similar accepted make: krishna trading corporation . [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

State Government

CTN :45107721 Due date: 19 Jun, 202619 Jun, 2026 92.50 Lacs
Tender For corrigendum : tender for the supply, installation and commissioning of di-electric tube sealer on 2 years rate contract as mentioned against item in schedule of requirement.

CTN :45112925 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For bid to ras tender for supply of disconnecting ht and lt supply taking down the defective transformer indoor outdoor type from four pole two pole structure or lifting from the outdoor type foundation or taking out from sub station bldg using a crane of suitable capacity and slings ropes etc as required and shifting the same to civil workshop for repairs complete all as directed for transformer capacity 400 kva , shifting back the repaired transformer indoor outdoor type from civil workshop to site reinstalling at original position and fixing properly on four pole two pole structure or outdoor type foundation or inside a sub station bldg using a crane of suitable capacity and slings ropes etc as required making ht lt side connections and testing for satisfactorily working complete all as directed for transformer of capacity 400 kva , draining out transformer oil from the transformer and storing the same in suitable containers to be arranged by contractor without any extra cost opening the top cover and lifting up the core assembly carefully to check the condition of transformer windings and core retanking the same after repairing checking of leakage from transformer body and repairing welding works required for making transformer body leak proof refilling the transformer oil dully dehydrated and filtered dehydration and filteration to be paid separately and making all connections with ht lt side bushings refixing the top cover and testing the transformer with a suitable capacity insulation tester complete all as directed for transformer of cap 400 kva , m and l for rewinding of burnt out defective ht copper coils with new super enamelled heavy duty copper winding wires of size matching to the existing one including varnishing drying in a suitable oven and all insulating material such as cotton sleeves tapes etc and connections with bushing terminals complete all as specified and directed , all as per item no 4 above but lt copper coils complete all as specified and directed , m and l for painting the transformer tank from inside with two coats of zinc chromite after preparing the tank walls bottom top cover inner side by properly cleaning the surfaces oil free complete all as directed for transformer capacity 400 kva , m and l for replacement of defective ht porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , m and l for replacement of defective lt porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , dehydration and filteration of transformer oil for indoor outdoor type transformers of any capacity at site using transformer oil filteration plant to improve di electric strength not less than 45 kv at 2 point 5 mm electrode gap complete all as directed note unit rate quoted shall be deemed to include the charges for hiring of oil filteration plant shifting to different locations at cantt area testing of samples of oil as per requirement and nothing extra will be paid on this account , s and f new transformer oil for replacement or topping up the level of oil having dielectric strength not less than 45 complete all as specified and directed

CTN :45475408 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For rate contract for supply of electric material(ht/lt) t&p/equipments/hardware items etc.for std udhampur -balance items. note :the bidders are advised to quote the reasonable rates for supply of all the items mentioned in boq. any rate quoted as zero shall be assumed that the firm is unwilling to supply the particular item and next lowest rate shall be considered as l1 for that particular item. - xlpe power cable (make havells or any other reputed make conforming to relevant is specifications) :, 11 kv single-core xlpe armoured cable 630 mm2, 11 kv 3-core xlpe armoured cable 185 mm2, twin core al lt cable 16 mm2 pvc cable (al), lt xlpe al cable 3.5 core armoured x95 sqmm (3 x 95 + 1 x 70 + 1 x 16), 33 kv cable termination kits outdoor (make havells or any other reputed make conforming to relevant is specifications) :, cable termination kits 33 kv heat shrinkable outdoor type 300 mm2 (single core), 33 kv cable termination kits heat shrinkable 300 sqmm -3 core, 33 kv cable termination kits heat shrinkable 240 sqmm -3 core, 33 kv cable termination kits heat shrinkable 185 sqmm -3 core, 11 kv cable termination kits outdoor/indoor (make havells or any other reputed make conforming to relevant is specifications), a)cable kits 11 kv heat shrinkable indoor 630 mm2 (single core), b) cable kits 11 kv heat shrinkable indoor 400 mm2- 3 core, c) cable kits 11 kv heat shrinkable indoor 300 mm2 - 3 core, d) cable kits 11 kv heat shrinkable indoor 240 mm- 3 core, e) cable kits 11 kv heat shrinkable indoor 185mm2 - 3 core, f) cable kits 11 kv heat shrinkable indoor 120 mm2 - 3 core, g) cable kits 11 kv heat shrinkable outdoor 630 mm2 - 1 core, i)cable kits 11 kv heat shrinkable outdoor 400 mm2 - 3 core, j) cable kits 11 kv heat shrinkable outdoor 240 mm2- 3 core, k) cable kits 11 kv heat shrinkable outdoor 185 mm2- 3 core, l) cable kits 11 kv heat shrinkable outdoor 120 mm2- 3 core, 11 kv straight through joints, 11 kv cable straight through joints heat shrinkable 240 sqmm - 3 core, 11 kv cable straight through joints heat shrinkable 185 sqmm - 3 core, e)11 kv cable straight through joints heat shrinkable 120 sqmm - 3 core, control cable, a) 2.5 mm2 cu 2-core, b) 2.5 mm2 cu 4-core, c) 2.5 mm2 cu 6-core, d) 2.5 mm2 cu 8-core, e) 2.5 mm2 cu 10-core, f) 2.5 mm2 cu 12-core, g) 2.5 mm2 cu 16-core, battery chargers & battery bank , maintenance free 32 v lead acid battery (vrla) bank comprising of 16 nos of 2 volt cells of 100 ah capacity make hbl, exide, amaraja etc, 32 v battery charger automatic (float & boost) compatible for vrla batteries, 3 phase, 415 v ac , 50 hz ,4 wire 36 v , 30-40 a, with 4 outgoing feeders and with all protections, 33 kv & 11 kv insulators make iec, bhel, rastriya, top line, tcpl or any other reputed make conforming to relevant is specification , 33 kv post insulator 24 mm, 11 kv guy insulator 90 x 65, 33 kv hardware fittings, 33 kv tension fittings for acsr dog conductor, t & c 3 u-bolts type (approx. 2.8 kg) al wt 400 gm, 33 kv suspension fittings for acsr dog conductor -( wt 1.8 kg), spares for 11 kv vcb panels, a) male / female contacts mei make, b) 11 kv pt fuse, c) 11 kv vcb bottle assembly bracket, d) shower contact mei make, e) shower contact crompton greaves make, spring charging dc motor for 11 kv vcb panel( make delco), tripping coil suitable for vcb panels (operating voltage 30-36 volt dc) with plunger, ampere meter 96mm x 96 mm for 11 kv vcb panel (digital), voltmeter 96mm x 96 mm for 11 kv vcb panel (digital), indicator lamp for vcb panel voltage 50-250 v ac/dc., tnc switch for 11 kv/ 33kv vcb panels, space heaters with thermostat for 11 kv vcb panels, 11 kv vacuum interupter bottle with makes, a) g.e., b) crompton greaves, c) allind, d) alstrom, e) bhel /a.b.b, master trip relay ashida (make) 18-52 (v), 11 kv cts resin cast of different ratios, make mei/ bicco lawrie / crompton greaves / bhel/ er/ ssg/ alstorm/ megawin/ sudhir/electricfield for 11 kv vcb panels(indoor/outdoor), i) 800/400/

CTN :45056878 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For corrigendum : supply of miniature circuit breaker gv2me10,3 poles, 3d, 4-6.3a, 50hz, ac-3, cat-a thermomagnetic strip unit, type-gv2me10 with add on contact 1 no & 1 nc type gz1an11. make-schneider electric or similar. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

CTN :45474275 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For supply of miniature circuit breaker gv2me10,3 poles, 3d, 4-6.3a, 50hz, ac-3, cat-a thermomagnetic strip unit, type-gv2me10 with add on contact 1 no & 1 nc type gz1an11. make-schneider electric or similar. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

CTN :45471262 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For supply of relay for control electronics off/temperature, make-schneider electric france, type- cad 32 fd as per clw's spec. no.-clw/es/3/0066 (alt.- b) [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variationpermitted: max 8 lacs ] ]
 Loading, Please wait...

Connect us via What's Up