Tender For 1. solid state over voltage relay for transformer rectifier unit of rmpu coaches. specn: specification no: drg. icf specification n0,icf/elect/897 rev.o or latest.;2. insulation monitoring relay 110 volt ac, range 50 v to 200 v ac insulation measuring range 25 kilo ohm to 100 kilo ohm, control supply-230 volts, 50 hz having fault memory test and reset button and alarm lead as per rcf specification edts-073 rev d amend 3. as per drg.no. nil specn: rcf specification edts-073 rev d amend 3;3. mpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 %u2013 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 %u2013 2015 (rev. 0)4. set of thermal expansion valve suitable for lhb rmpu ac unit of 3.5 ton-conforming to rdso spec:-rdso/pe/spec/ac/0061-2005(rev.-1) one set contains two valve. 1] sporlan-ebve :7/8
Tender For tender for supply of 2way 2pole without off selector swpoint , minature circuit breaker , mcp 2p 2a , emergency push button , 1 cx1point0 sqpoint mmpoint lfh cable as per nes 518 , 1 cx1point0 sqpoint mmpoint lfh cable as per nes 518 , 1 cx2point5 sqpoint mmpoint lfh cable as per nes 518 , 2cx0point5 sqpoint mm overall atc shielded with core , 4cx0point75 sqpoint mmpoint overall atc shielded with core , 1cx4point0 sqpoint mmpoint lfh cable as per nes 518 , emi filter type , emi gasket type 1516 00121 02 , dc dcconvertor 24v 6point3a 150w i p 19 36v , 3c x0point75 sqpoint mm shielded uniflex lfh cable , 6c x0point75 sqpoint mm shielded uniflex lfh cable , horn , dc dc convertor , relays 2c o 24 vdc , relay socket , ethernet switch , 4 c 0 control relay , plc power supply , plc 32do , selector swpoint , cable glands , terminals , connector for dc convertor , 3c 6 sqpoint mm shielded uniflex lfh cable as per nes 18 , 3c 4 sqpoint mm shielded uniflex lfh cable as per nes 518 , dc on off switch , 4c 2point5 sqpoint mm shielded uniflex lfh cable as per nes 518 , 2c 1point0 sqpoint mm shielded uniflex lfh cable as per nes 518 , 4c 0point75 sqpoint mm shielded uniflex lfh cable as per nes 518 , 2c 1point5 sqpoint mm shielded uniflex lfh cable as per nes 518 , 5x3c 0point75 sqpoint mm shielded uniflex lfh cable as per nes 518 , plc 32di , 11x3c 0point75 sqpoint mm shielded uniflex lfh cable as per nes 518 , connection cable for 40 pin connector , communication cable , 18c 2point5 sqpoint mm shielded uniflex lfh cable as per nes 518 , 19c 1point5 sqpoint mm shielded uniflex lfh cable as per nes 518 , diode module 30 input terminals 1 lamp test , 10c 2point5 sqpoint mm shielded uniflex lfh cable as per nes 518 , backplane extension cable 1point5m , lugs , plc cpu me , plc 32ai 4 20 ma , line terminator , plc cpu ethernet cable , me plc application software cd , standard backplane extender , universal scanner 1 , indicating lamp annouciator , push button yellow , push button green , push button red , shock mounts , communication material set , push button white , laptop , plc software cd , plc programming cable , plc panel fabrication
Tender For supply of procurement of spares prabhu make flp lt ht starter dp and geb d d ? g? g - contactor complete 400 amps. 3. 3kv, part no. ht-200 , vacuum contactor rectifier bridge, part no. ht-201 , bottle for vacuum contactor 3. 3kv, 400 amps, part no. ht-202 , vacuum contactor closing coil 110v dc, part no. ht-203 , vacuum contactor holding coil 110v dc, part no. ht-204 , auxiliary switch for vacuum contactor 2no 2 nc, part no. ht-205 , p. t. 40va 0-8-12v 0-110v, part no. ht-206 , auxilary contactor 3 no 1 nc 110v ac, part no. ht-208 , resin cast p. t. 750va 3. 3kv 110 volts single phase, part no. ht-300 , h. t control fuse 3. 3kv, 2 amps, part no. ht400 , copper busbar 400amps set of three, part no. ht-101 , resin cast moulded c. t. for o l 3. 3kv, part no. ht-600 , dmc moulded 3. 3kv insulator for power fuse, part no. ht700 , push button with element for start, stop, test and reset, part no. ht--1300 , lamp holder with lamp for starter, part no. ht-1400 , brass cable gland complete with c. i clamp, stud , part no. ht-1600 , s t idmtl o c and s c r with time leg o l setting - 50 percent to 200 percent and s c setting 400 percent to 1600percent of flc, part no. ht-900a , e. l unit complete without transformer, part no. ht-800 , dmc moulded copper terminal 400a, 3. 3kv , part no. flp vcb 045 , isolator 100 amps reversing, part no. fs- 2 002 , air break contactor 40amps upto 20hp 550v starter, part no. fs- 2 003c , air break contactor 63amps upto 30hp 550v starter, part no. fs- 2 003e , auxiliary transformer 80va pri-500 525 550v sec-0-8-12, 0-110v, part no. fs- 2 004c , dmc terminal for i c ,t g,o g and partition 100 amps, part no. fs- 2 008 , dmc auxilary terminal, part fs2 009 , 3 pole magnetic o l relay type direct acting, part fs- 2 010 , direct acting thermal overload relay upto 30hp starter, part no. fs-2 010a , 65 sq mm ammeter ct operated, part no. fs-2 011 , 65 sq mm ammeter direct acting, part no. fs-2 011a , ct for ammeter, part no. fs-2 012 , short circuit hrc fuses 63 amps, part no. fs- 2 014e , auxilary contactor 2 no 2 nc 110v 415v 500v, part no. fs- 2 020 , pilot relay 12v dc, part no. fs- 2 026 , s e l r with cbct and p. t. el setting 50ma to 750ma with time delay 0. 1 to 1 sec in step of 0. 1 sec with test and reset micro switch and conc wire, part no. fs- 2 037 , isolator 200 amps reversing, part no. fs- 3 002b , isolator 300 amps reversing, part no. fs- 3 002c , air break contactor 185amps, fs- 3 003h , air break contactor 300amps, fs- 3 003l , air break contactor 325 330amps, fs- 3 003m , dmc terminal for i c and t g 300 amps, fs- 3 008a , dmc terminal for i c and t g 400 amps, fs- 3 008b , dmc terminal for outgoing partition 300 amps, fs- 3 009b , dmc auxilary terminal, fs- 3 010 , 3 pole magnetic o l relay type ct operated, part fs- 3 011a , ct operated thermal overload relay 4. 5 to 7. 5a with mounting kit, fs-3 011c , ct for overload relay,fs- 3 012 , 65 72 sq mm ammeter ct operated,fs- 3 012b , 65 or 72 sq mm voltmeter 0-600v, fs- 3 012d , pilot relay 12v dc, part no. fs- 3 026 , s e l r with cbct and p. t. e l setting 50ma to 750ma with time delay 0. 1 to 1 sec in step of 0. 1 sec with test and reset micro switch and conc wire,part no. fs- 3 041 25 amps contactor with 110v coil, part no. dpf-1 002a, hrc fuse base with carrier, part no. dpf-1 004, hrc fuse link,10 amps, part no. dpf-1 004a, e l. trip indication lamp, part no. dpf-1 006a, glass fuse. 1 amp, part no. dpf-1 007a, glass fuse. 2 amps, part no. dpf-1 007b, on off toggle switch, part no. dpf-1 008, incoming throughgoing dmc,moulded terminal with brass stud, part no. dpf-1 013, interconnecting dmc, moulded terminal with brass, part no. dpf-1 013a, condensor,16v,220 mfd. , part no. dpf-1 019, m 8 //bid details2 / 59
Tender For procurement of emergency breakdown van for ohe with full t&p equipment required for maintenance of ohe in the project of vr-drd & pnvl-kjt. - integrated testing equipment system with vanfor tss & ssp as per specification attached in annexure -i, fully automatic cable fault locating system annexure - ii, individual testing equipments as per annexure-iii3.1 thermal imager hand held camera as per specification (640 x 480), individual testing equipments as per annexure-iii3.2 power quality analyser with clamp set, individual testing equipments as per annexure-iii3.3 battery load unit, individual testing equipments as per annexure-iii3.4 third harmonics leakage current monitoring, individual testing equipments as per annexure-iii3.5 digital earth tester stake less & stake measurement, individual testing equipments as per annexure-iii3.6 automatic oil tan delta, individual testing equipments as per annexure-iii3.7 cable identifier, individual testing equipments as per annexure-iii3.8 sf6 gas analyser, individual testing equipments as per annexure-iii3.9 3 phase relay test set toolbox for substation, individual testing equipments as per annexure-iii3.10 battery ground fault tracer, individual testing equipments as per annexure-iii3.11 primary current injection test system for 2000a, individual testing equipments as per annexure-iii3.12 circuit breaker analyser